User manual

DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Managing multimedia calling
210Multimedia Applications Server Interface
9
Step 5 — Administer a signaling group
For each MASI node, you need to establish a unique signaling group. Use the
command
add signaling-group xxx to access the Signaling Group form.
Screen 1. Signaling Group Form (Page 1 of 5)
For each link, establish a Non-Call Associated Temporary Signaling Connection
(NCA-TSC) with the following attributes:
Associated Signaling MASI requires Facility Associated Signaling, so
this field must be set to y.
Primary D-channel Enter a 6- to 7-character port number associated
with the DS1 Interface circuit pack port. The port address of the PRI that
carries D-channel signaling.
The port number is used to assign the primary D-channel in the Signaling
Group. For 24-channel facilities, the 24th port is assigned as the D-channel.
For 32-channel facilities, the 16th port is assigned as the D-channel.
Max Number of NCA TSC
For MASI, this must be 1.
Max number of CA TSC
Leave the default of 0.
Trunk Group For NCA TSC
This can be left blank.
Trunk Group for Channel Selection This can be left blank.
Page 1 of 5
SIGNALING GROUP
Group Number: _ Associated Signaling? y Max number of NCA TSC: __
Primary D-Channel: ______ Max number of CA TSC: __
Trunk Group for NCA TSC: __
Trunk Group for Channel Selection: ___