644Feature-Related System Parameters
17
Time Before Off-Hook Alert
Emergency Access Redirection Extension
Number of Emergency Calls Allowed in
Attendant Queue
Call Pickup Alerting
This provides pickup group members with a visual indication on the Call Pickup
status lamp of calls eligible to be answered via Call Pickup.
Temporary Bridged Appearance on Call Pickup
Valid entries Usage
1
to 3000 seconds Enter the time in seconds that a telephone with an
Off-Hook Alert Class of Service can remain off-hook
(after intercept tone has started) before an emergency
call is sent to the attendant.
Valid entries Usage
An assigned extension Enter the assigned extension number (can be a
VDN) where emergency queue overflow will
redirect.
Valid entries Usage
0
75 Enter the number of calls allowed in the attendant queue before
additional calls are routed to the backup extension.
Valid entries Usage
y/n
Enter y to enable Call Pickup Alerting on a system-wide basis.
Valid entries Usage
y
Enter y to allow a temporary bridged appearance for calls
answered with the Call Pickup or Directed Call Pickup features.
This field controls this capability on a system-wide basis.
n
Enter n to prevent the temporary bridged appearance of calls
answered with these features.