DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
703Hunt Group
17
(Calls Warning) Port
Appears if the Queue field is
y. Enter the seven-character port number assigned to
connect the optional external Auxiliary Queue Call Warning Threshold lamp that
will flash when the number of calls in queue has exceeded the queue warning
threshold (assigned in Calls Warning Threshold).
NOTE:
This port is assigned to an Analog Line circuit pack or given an "X"
designation if an extension is used.
For example, 01A0612 is in cabinet 01, carrier A, slot 06, and circuit number
(port) 12.
(Calls Warning) Extension
Appears if the Queue field is
y and when the Calling Warning Port and the Time
Warning Port fields are
X. An extension is needed when an X is placed in Calls
Warning Port. This extension can be used by the Terminal Translation
Initialization (TTI) feature to assign a port to this extension from the port itself.
Once Calls Warning Port is assigned a valid port (either via TTI or the
change
hunt-group
command), then the extension is removed and considered
unassigned.
Valid entries Usage
01
through 44 First and second characters are cabinet number
01 through 03
01
A
through E Third character is the carrier
01 through 20 Fourth and fifth characters are the slot number
01 through 16 Sixth and seventh characters are the circuit number
Valid entries Usage
Enter an unassigned extension. This field may not be blank.