User manual

DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
819Modem Pool Group
17
Modem Name
Indicates the name of the modem pool. This field appears only when the Group
Type field is
combined.
Hold Time (min)
Enter the maximum number of minutes that a conversion resource in the group
may be held while a call waits in a queue or reserved after Data Call Preindication.
Send Space Disconnect
This field appears only when the Group Type field is
integrated.
Time Delay
Enter the time delay in seconds to insert between sending the ringing to the
modem and the off-hook alert to the data module. This field appears only when
the Group Type field is
combined.
Receive Space Disconnect
This field appears only when the Group Type field is
integrated.
Valid entries Usage
1- to 6-alphanumeric character string
Valid entries Usage
1
through 99
Valid entries Usage
y/n
Enter y to allow the conversion resource to send 4 seconds of
space before disconnecting.
Valid entries Usage
0
through 255
Valid entries Usage
y/n
Enter y to allow the conversion resource to disconnect after
receiving 1.6 seconds of space.