10.2.5 Replacingthehydraulicuid
- Change the hydraulic uid after approximately 500 operating hours, and every two years
at the latest.
- It must always be changed whenever the hydraulic uid for the accompanying pump
(motor / hand pump) is changed. This prevents the fresh uid from being contaminated by
the used uid from the recycling unit.
Procedure:
1. Close crusher arms (until the tips are almost touching).
2. Change the hydraulic uid of the pump. Please observe the separate operating instructions
for the pump being used!
3. Screw off the return hose on the pump:
- when the hose connection is via mono-coupling to the pump:
remove the cover from the mono-coupling (male).
completely unscrew the connection nut of the blue return hose on the mono-coupling
(male).
- when the hose connection is via quick-connect-coupling to the pump:
Release the union nut on the hose completely from the plug connector nipple on the
blue return ow line.
4. Put the return hose into a separate collecting basin for the hydraulic uid still in the
equipment.
5. Slowly open the crusher arms on the tool (the pump must be working during this time).
The old hydraulic uid from the ring space side runs via the return hose into the separate
collecting basin, and must be disposed of in the same manner as the old hydraulic uid
from the pump.
6. Switch the pump off (motor pump) / no longer activate it (e.g. hand pump).
7. Reconnect the return hose to the pump:
- when the hose connection is via mono-coupling to the pump:
screw the connection nut of the blue return hose back onto the mono-coupling (male).
(Please observe the necessary torque of M
A
= 40 Nm!)
Pull back the cover on the couplings as far as the limit stop.
- when the hose connection is via quick-connect-coupling to the pump:
Screw the union nut on the hose on the plug connector nipple on the blue return ow line.
(Please observe the necessary torque of M
A
= 35 Nm!)
8. De-aerate the recycling unit as described in the chapter “Preparatory measures”.