11.2 Preventive maintenance
11.2.1 Maintenance instructions
The exterior of the device must be cleaned from time to time. In order to protect it from
corrosion, a suitable agent must be applied to the metallic surfaces.
(In case of doubt, contact your authorised LUKAS dealer or LUKAS directly!)
ATTENTION!
Always perform the change of the hydraulic uid over a collection tank and
dispose of the collected uid in a proper manner!
ATTENTION!
The hydraulic uid must be completely replaced if the application conditions
(ambient temperatures) change substantially. When selecting a suitable hydraulic
uid, please refer to chapter “Hydraulic uid recommendations”.
Procedure:
1. Completely retract the cylinder.
2. Dismantle the valve blocks on the cylinder.
3. Drain off the hydraulic uid.
4. Flush.
5. Re-mount the valve blocks.
6. Connect the pump with fresh hydraulic uid.
7. De-aerate as described in Chapter “First operation".
7. Re-connect the pump.
11.2.2 Function and load test
If there is any doubt regarding the safety or reliability of the equipment, a function and load
test must also be performed.
11.2.3 Changingthehydraulicuid
- The hydraulic uid must be changed after the equipment has been used approx. 200
times / after three years at the latest.