11.2 Preventive maintenance
11.2.1 Maintenance instructions
The exterior of the device must be cleaned from time to time. In order to protect it from
corrosion, a suitable agent must be applied to the metallic surfaces.
(In case of doubt, contact your authorised LUKAS dealer or LUKAS directly!)
ATTENTION!
Always perform the change of the hydraulic uid over a collection tank and
dispose of the collected uid in a proper manner!
ATTENTION!
The hydraulic uid must be completely replaced if the application conditions
(ambient temperatures) change substantially. When selecting a suitable hydraulic
uid, please refer to chapter “Hydraulic uid recommendations”.
Procedure:
1. Completely retract the cylinder.
2. Dismantle the valve blocks on the cylinder.
3. Drain off the hydraulic uid.
4. Flush.
5. Re-mount the valve blocks.
6. Connect the pump with fresh hydraulic uid.
7. De-aerate as described in Chapter “First operation".
7. Re-connect the pump.
11.2.2 Function and load test
If there is any doubt regarding the safety or reliability of the equipment, a function and load
test must also be performed.
11.2.3 Changingthehydraulicuid
- The hydraulic uid must be changed after the equipment has been used approx. 200
times / after three years at the latest.