Manual
42
11.6 Operating and storage temperature ranges
Operating temperature [°C] / [°F] -20 … +55 -4 … +131
Ambient temperature
(device in operation)
[°C] /
[°F] -25 … +45 -13 … +113
Storage temperature
(device not in operation)
[°C] /
[°F] -30 … +60 -22 … +140
11.7 Oscillation / vibration
The total oscillation value / vibration value to which the upper limbs are exposed, is usually
below 2.5 m/s².
Higher values may be measured for short periods as a result of interaction with the materials
to be processed.
(The oscillations / vibrations were determined in accordance with DIN EN ISO 20643.)
11.5.2 R411E:
Battery type used for device Lithium / ion
No-load operation
(measuring distance: 1m)
[dB(A)] 78
full load operation
(measuring distance: 1m)
[dB(A)] 79
No-load operation
(measuring distance: 5m)
[dB(A)] 71
full load operation
(measuring distance: 5m)
[dB(A)] 72
11.8 Tightening torques for pivot bolts (cutters and combi tools only)
type S 311 E S 700 E SC 250 E SC 350 E
pivot bolt M 24 x 1,5 M32 x 1,5 M 24 x 2 M 24 x 1,5
wrench size
[mm] 36 46 36 36
[in.] 1.42 1.81 1.42 1.42
torque
[Nm] 120 +10 140 + 10 110 +10 120 +10
[lbf.in.] 1,062 + 89 1,239 + 89 890 + 89 1,062 + 89