8.2 Protective equipment
Check the protective equipment used on / in the vicinity of the rescue device. Pay particular
attention to the protective cover for the movable parts (there may be no cracks!).
Battery and power supply
• Casing undamaged,
Electrical contact surfaces clean and undamaged
• Cable undamaged
Battery(-ies) fully charged (when used)
Charging state display of lithium-ion battery or batteries fully functional
Functional test
Easy opening and closing or extension/retraction of star grip controls,
No unusual noises
No further movement of cutter and spreader arms or ram piston when interrupting the
The air suction lter is to be checked at least once a year or after use in a dusty environment.
The lter can be checked from the outside if the mains unit (or battery) is removed (see
illustrations below).
If the lter is severely contaminated, it will need to be replaced.
Procedure:
1. Tilt the respective device as shown in the illustration.
2. Remove the battery or the power supply.
3. Remove the lter grid by activating the release hook.
4. Replace the dirty lter elements with new lter elements.
8.3 Checking the lter in the battery shaft
Release hook