User Manual
27
Procedure:
1. Close the rescue unit until a gap of only a few mm remains between the tips. Disconnect
the device from the hydraulic power supply unit and clean thoroughly.
3. Pull the handle “D” backwards over the hose
connections.
A
B
C
D
B
B
10.3.4 Spreader arm, spreader tips, protection cover and handle replacement
(SP 510 and SP 512)
EF
4. In the same way, pull the protective cover
“E” backwards over the hose connections.
Components to be
replaced
Required work steps
Handle 1. - 3. and 7.
Protective cover 1. - 4. and 7.
Plug-on tips 1. - 5. and 7.
Lever links 1. - 5. and 7.
Spreader arms 1. - 6. and 7.
2. Unscrew nuts “A”, remove washers “B” and
remove fi xing bolts “C”.