Manual

Series IN 500 Operating Manual Data format UPP (Universal Pyrometer Protocol) 32
Description
Command
Parameters
Reading measuring
value:
AAms
Output: YYYYY; 5
-
digit decimal, in
1
/
10
°C or °F
88880 = temperature-overflow
75550 = exceed max. sensor head temp.
74440 = fall below min. sensor head temp.
02563 = 256.3 °C or °F; -0170 = -17.0 °C or °F
repeatedly reading
measuring values:
AAmsXXX
XXX = 000 ... 999
XXX = Number of measuring values
Emissivity:
AAemXXXX
XXXX = 0100 ... 1200 in ‰
R
esponse time t
90
:
AAezX
X =
0 ... 6 (decimal)
0 = intrinsic time constant of the device
1 = 0.5 s 2 = 1 s 3 = 2 s
4 = 5 s 5 = 10 s 6 = 30 s
Setting clear time t
CL
:
AA
l
zX
X =
0 ... 8 (decimal)
0 = Max. value- / min. value storage off
1 = 0.10 s 5 = 5.00 s
2 = 0.25 s 6 = 25.00 s
3 = 0.50 s 7 = external clearing
4 = 1.00 s 8 = automatic clearing
External clearing:
AA
l
x
Simulation of an external reset contact
Setting maximum /
minimum value:
AAmiX
X = desired setting
0 = maximum value, 1 = minimum value
Read. max/min value:
AAmi
Output
: 0 or 1; 0 = max value, 1 = min value
Reading basic
measuring range:
AAmb
Output: YYYYZZZZ
(8
-
digit hex)
2)
YYYY = beginning of measuring range
ZZZZ = end of measuring range
Reading sub range:
AAme
as with
mb
Setting sub range:
AAm1YYYYZZZZ
YYYY = beginning of measuring range
ZZZZ = end of measuring range
Analog output
1)
:
AAasX
X =
0 ... 4
2 = 0 ... 5 V
0 = 0 ... 20 mA 3 = thermocouple
type K
1 = 4 ... 20 mA 4 = thermocouple
type J
Temperature displ
ay
1)
:
AAfhX
X = 0;1
0
= Output Celsius
1 = Output Fahrenheit
Reading ambient
temperature:
AAut
Output: stored value, 4
-
digit hex
2)
e.g. 0258 corresponds to 600 degrees
Entering ambient
temperature:
AAutXXXX
XXXX = Value of ambient temp., 4
-
digit he
x
2)
XXXX z.B. FFEC corresponds to -20 degrees
-99
dez
= FF9D
hex
means: automatic, no
manual compensation
Sensor head temp.:
AAgt
Output: XXX (dec. 000...180
°C or 032...356
°F)
Max. sensor head
temp.:
AAtm
Output: XXX (dec. 000...180
°C or 032...356
°F)
Baud rate:
AAbrX
X =
0 ... 4
0: 1200 bd
1: 2400 bd
2: 4800 bd 3: 9600 bd 4: 19200 bd
Instrument address
1)
:
AAgaXX
XX: device address decimal;
00
... 31 variable
device addresses; global: 98, 99
Reading switch point:
AAs
l
Output: XXXX (4
-
digit h
ex)
2)
Setting switch point:
AAs
l
XXXX
XXXX (4
-
digit hex)
2)
; adjustable within sub
range