Series FR587W Deluxe Clinical Care Recliner, Extra Wide Series FR587WH Deluxe Clinical Care Recliner, Extra Wide, with Heat and Massage Assembly and Operating Instructions IMPORTANT: READ THIS MANUAL BEFORE OPERATING YOUR LUMEX FR587W / FR587WH DELUXE EXTRA-WIDE CLINICAL CARE RECLINER. SAVE THIS MANUAL FOR FUTURE USE. THE MOST CURRENT VERSION OF THIS MANUAL CAN BE FOUND ONLINE AT www.grahamfield.com.
CONTENTS INTRODUCTION........................................................................................................................................................3 INTENDED.USE..................................................................................................................................................3 IMPORTANT.SAFETY.PRECAUTIONS—PLEASE.READ.BEFORE.USE........................................................ 3 WARNINGS...........................................................
INTRODUCTION This manual contains assembly, operation, and maintenance instructions for the Lumex Clinical Care Recliners Series FR587W and FR587WH. Read the entire manual carefully before using your recliner, and refer to it during use if you have questions. If you have further questions, please call Graham-Field / Lumex Technical Support at 770-447-1609. INTENDED USE Lumex Clinical Care Recliners are intended to make the care, treatment and recovery of patients easier and more comfortable.
. WARNING:.This.product.has.a.maximum.weight.capacity.of.450.lb.(204.kg),.EVENLY. DISTRIBUTED. . WARNING:.Casters.must.be.locked.at.all.times,.except.during.transport. . WARNING:.Unauthorized.modification.of.your.recliner.or.the.use.of.non-Lumex. replacement.parts.may.change.the.structure.of.the.recliner.and.could.create.a. hazardous.condition,.which.may.result.in.serious.injury.and.will.void.the.warranty. . WARNING:.Notice.for.California.Customers-.California.Proposition.65.WARNING: This.product.contains.
ASSEMBLY UNPACKING 1. Check for obvious damage to the carton or its contents. If damage is evident, please notify the carrier and your Graham-Field authorized distributor. 2. Remove all packaging materials from recliner base.
3. Remove cardboard shipping retainers and tape from around gas spring cylinders. Rotate the hinge section on the gas spring so that it is perpendicular to the upholstered back, as shown at right. gas spring hinge Rotate HInge panel tabs side panel 4. Remove side panels from frame: Depress the two push buttons located on the lower sides of frame. Pull side panel gently away and down from frame. There are tabs on the frame underneath the armrest that hold the side panel in place.
8. Raise the upholstered back to vertical position. Tuck the plastic skirt at rear of upholstered back behind seat frame crossbrace. Align the hinges at the bottom of the gas springs with the holes in the U-brackets on the seat frame crossbrace. While holding the back in position with one hand, secure both gas spring hinges to the U-brackets by placing two 5/16"diameter clevis pins through the U-brackets and hinges with the other hand. Place Clevis Pins 9.
OPERATION . WARNING:.Disconnection.of.the.device:.In.case.of.emergency,.always.disconnect. the.device.by.removing.the.power.cord.plug.from.the.power.outlet. TENTE® CASTERS . WARNING:.Casters.must.be.locked.at.all.times,.except.during.transport. All Lumex Clinical Care Recliners now feature the latest design, all-plastic casters from TENTE. Specifically designed for use in healthcare environments, the new casters are easier to clean, easier to move, and tolerate a wide array of cleaners and chemicals.
SIDE TABLE OPERATION To raise table: Raise the side table all the way up and slide in toward the armrest until tabs engage slots in mount bracket. Press down lightly on table to ensure locking tabs are engaged. To lower table: Lift the side table up slightly until tabs disengage slots and pull table away from armrest. Lower side table to self-storing position.
SIDE PANEL OPERATION For easy cleaning and access to the side and underside of the recliner, Lumex Clinical Care Recliners feature easy-to-remove side panels. To remove side panel: Depress the two push buttons located on the lower sides of frame. Pull side panel gently away and down from frame. There are tabs on the frame underneath the armrest that hold the side panel in place. To install side panel: Insert side panel into recliner frame by locating the tabs underneath the armrest.
RECLINER OPERATION The Lumex Series FR587W and FR587WH Recliners feature three positions for patient comfort. The fourth position is a Trendelenburg (or Shock Position) that must be activated by a caregiver. The Trendelenburg Position CANNOT be activated by a patient while in the recliner. In addition, the Series FR587W features a back that can be repositioned via the adjustment lever located on the push handle on the back of the recliner.
Info: Due to the 450 pound weight capacity (when evenly distributed) the FR587W Recliner has two gas pistons to assist in the recline and return of the back. One piston assists during the rearward movement of the back, the other piston assists during the return of the back to an upright position. For thisUpright reason, in order for Position the gas piston to operate properly, a person of at least 150 lb (68 kg) should be sitting in the recliner.
GAS SPRING TROUBLESHOOTING GUIDE Info: gas springs have been pre-adjusted at factory The gas spring on your recliner provides counterbalancing forces, and is self-locking for infinite, precise positioning. Unlocking the gas spring is controlled by actuating the lever located on the padded push handle on the back of the recliner. When the lever is actuated it pulls on the cable which in turn pulls on a hinge, depressing a button at the end of the gas spring rod.
LUMEX CLINICAL CARE RECLINERS WITH HEAT AND MASSAGE FEATURE INSTALLATION AND OPERATING GUIDE Series FR587WH Tools required: 1/4" hex wrench and Phillips Screwdriver . WARNING:.Important!.Read.and.understand.these.instructions.before.assembling. or using.the.Specialty.Healthcare.Seating.Heat.and.Massage.Unit..If.you.do. not.understand.any.part.of.these.warnings,.cautions.or.instructions,.contact.a. healthcare.professional.for.direction.in.the.use.of.this.product..If.the.Heat.and. Massage.Unit.is.not.
2. The control module, the brains of the system, is inside the junction box. Both are shown at right. 3. The power supply, which has an 8-foot power cord that plugs into the wall power outlet, is shown at right. Control Module (Junction Box Cover Removed) Junction Box Heat and Massage Unit Setup Instructions . CAUTION:.To.prevent.personal.injury.and.damage.to.the.recliner. always.obtain.assistance.when.positioning.the.recliner.as. instructed.in.the.following.sections. 1.
9. Insert the Y-cable connector labeled UPPER into the back cushion cable connector also labeled UPPER until its locking tabs snap into place, as shown at right. 10. Insert the Y-cable connector labeled LOWER into the back cushion cable connector also labeled LOWER until its locking tabs snap into place, as shown at right. Connect Upper and Lower Cables 11.
5. The selector switch has THREE HEAT FUNCTION SETTINGS and FOUR MASSAGE FUNCTION SETTINGS as follows: a. HEAT FUNCTION SETTINGS: 1) Press selector switch UP for Setting 1: High Heat, 106°F (41°C), brightest LED. 2) Press selector switch UP AGAIN for Setting 2: Medium Heat, 104°F (40°C), bright LED. 3) Press selector switch UP AGAIN for Setting 3: Low Heat, 100°F (37°C), dim LED. 4) Press selector switch UP AGAIN: Heat function shuts off.
e. Are all cable connections to the control module (in the junction box) in place per the instructions? Are the connectors fully engaged? f. Are any of the connectors damaged? g. Are the wires within the connectors attached to the pins? Each wire may have to be tugged lightly to check if the wire is still crimped to the pin. 4. POST-INSPECTION: a. If improper or loose connections are found, reconnect them firmly (unless a loose wire has been found).
CARE AND MAINTENANCE . WARNING:.Inspect.all.components.periodically.and.replace.as.needed. EVERY THREE MONTHS • Check and clean casters. • Tighten bolts in each leg that secure caster into frame. • Check brakes on casters. • Check and clean lock recline mechanism. • Check recliner mechanism for operation in all positions, including Trendelenburg Position, with assistant seated in recliner. UPHOLSTERY MAINTENANCE AND STAIN REMOVAL • Ordinary dirt: wash with warm water and a mild soap or detergent.
The information published in this care guide refers to the performance of PERMABLOK3 products in specific tests conducted under laboratory conditions. Results may vary under actual conditions. This information is not a guarantee and does not relieve the user from the responsibility of the proper and safe use of the product and all cleaning agents. The use of certain agents can be harmful to the surface appearance and lifespan of vinyl.
• Detergent and water are adequate for cleaning surfaces in nonpatient-care areas (e.g., administrative offices). Clean and disinfect high-touch surfaces on a more frequent schedule than minimal-touch housekeeping surfaces. Clean walls, blinds, and window curtains in patient-care areas when they are visibly dusty or soiled. • Do not perform disinfectant fogging in patient-care areas. • Avoid large-surface cleaning methods that produce mists or aerosols, or disperse dust in patient-care areas.
TECHNICAL SPECIFICATIONS Overall.Height 50" Overall.Width 33" Overall.Depth 36" Width.Between.Arms 23" Arm.Height.from.Floor 26 1/2" Arm.Height.from.Seat 8" Seat.Height 21 1/2" Seat.Width 23 1/2" Seat.Depth 20 1/2" Depth.Fully.Reclined.in.Trendelenburg 76" Width.with.Both.Side.Tables.in.Upright.Position 53" Shipping.Weight 138 1/2 lb Maximum.Weight.
LIMITED WARRANTY GF Health Products, Inc. (“Graham-Field”) warrants the FR587W Deluxe Extra Wide Clinical Care Recliner and FR587WH Deluxe Extra Wide Clinical Care Recliner with Heat and Massage against manufacturing defects in materials and workmanship as listed below: Welded Frame .................... Lifetime limited (ten years) Heat and Massage Unit ..... Two year limited Upholstery ......................... One year limited All Other Components ......
GF Health Products, Inc. 2935 Northeast Parkway Atlanta, Georgia 30360 USA Telephone: 770-368-4700 Fax: 770-368-2386 Technical Support: 770-447-1609 www.grahamfield.