Datasheet
DS207 LUXEON 3030 2D Product Datasheet 20150319 ©2015 Lumileds Holding B.V. All rights reserved. 3
Product Selection
Product Selection Guide for LUXEON 3030 2D
Junction Temperature = 25°C
Table 1.
Nominal
CCT
Part Number
Minimum
CRI
[1]
Luminous Flux (lm)
[1]
@ 120mA
Luminous Flux (lm)
[2]
@ 100mA
R
th_J_c
(°C/W)
[3]
Minimum Typical Typical Typical
2700K L130-2780003000W21 80 80 96 82
12
2700K L130-2790003000W21 90 72 80 68
3000K L130-3080003000W21 80 85 98 83
3000K L130-3090003000W21 90 75 82 70
3500K L130-3580003000W21 80 85 101 85
4000K L130-4070003000W21 70 101 111 95
4000K L130-4080003000W21 80 90 105 89
5000K L130-5070003000W21 70 101 111 95
5000K L130-5080003000W21 80 90 105 89
5700K L130-5770003000W21 70 101 111 95
5700K L130-5780003000W21 80 90 105 89
6500K L130-6570003000W21 70 101 111 95
6500K L130-6580003000W21 80 90 105 89
Notes for Table 1:
1. Lumileds maintains a tolerance of ±7.5% on luminous ux, ±2 on CRI.
2. Interpolated value.
3. Thermal resistance is measured junction to case.