Datasheet

Time
120sec.
Max 150C
120max
Max 260C
30sec.
5sec.
Pre-heating
RT
Dip
Temp.(
)
120sec
Max 150C
5sec.
Max 240C
Time
Temp.()
Precautions For Use
This device should not be used in any type of fluid such as water, oil, organic solvent, etc.
When washing is required, IPA should be used.
When the LEDs are illuminating, operating current should be decided after considering the
ambient maximum temperature.
LEDs must be stored to maintain a clean atmosphere. If the LEDs are stored for 3months or
more after being shipped from LUMIMICRO, sealed container with a nitrogen atmosphere
should be used for storage.
The LEDs must be dip soldered within seven days after opening the moisture-proof packing.
Repack unused Products with anti-moisture packing, fold to close any opening and then store in
dry place. The appearance and specifications of the product may be modified for improvement
without notice. This LEDs are sensitive to the static electricity and surge. It is recommended
to use a wrist band or anti-electrostatic glove when handling the LEDs. If Over voltage which
exceeds the absolute maximum rating is applied to LEDs, it will cause damage in LEDs and
result in destruction. Damaged LEDs will show some unusual characteristics such as
remarkably increased leak current, turn-on voltage becomes lower and the LEDs get unlighted
at low current.
Soldering Condition
For
ForFor
For Manual
ManualManual
Manual Soldering
SolderingSoldering
Soldering
Not
more
than
5
seconds
@
MAX300
,
under
Soldering
iron.
Solder Dip Conditions
The Immersion of leads into a solder bath
@MAX260
shall be to 5 seconds max.
Reflow
ReflowReflow
Reflow Conditions
ConditionsConditions
Conditions
Preliminary heating to be at 150
max. for 2 minutes max.
Soldering heat to be at 240
max. for 5 seconds max.
6/9