™ Blood Pressure Monitor Advanced Technology Measures While Inflating Instruction Manual Model Number 1095 ID #08/01 Requires 4 “AAA” Alkaline Batteries 2 YEAR LIMITED WARRANTY
TABLE OF CONTENTS Identification of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Battery Installation/Replacement . . . . . . . . . . . . . . . . . . . . . . . . 4 Preparing to Use the Monitor -Using the Monitor Attached to the Arm Cuff. . . . . . . . . . . . . . . . . . . . . . . . 5 -Using as a Tabletop Monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Attaching the Arm Cuff and Posture During Measurement . . . . . . . . . . . . . . . . . . . .
Identification of Parts Peg Release Button LCD Display ON/OFF/START Button Arm Cuff with Air Plug Air Tube Memory Button Battery Cover Air Plug (to cuff) Release Button Air Tube Connector Air Plug (to monitor) 4 “AAA” size Alkaline Batteries 3
SmartInflate Technology Thank you for purchasing the Lumiscope™ 1095 Comfort Line Blood Pressure Monitor. A state of the art line of blood pressure monitors that MEASURE ON INFLATION UP TO TWICE AS FAST as traditional monitors, thus eliminating the pain and discomfort commonly felt with traditional styles.
The 1095 can be used either attached to the cuff or as a tabletop monitor with the enclosed airtube attachment. Preparing to Use the Monitor Fig. A Using the Monitor Attached to the Arm Cuff • Angle the bottom of the monitor against the raised part of the plastic piece on the cuff (fig. A). • Line up the holes on the back of the monitor with the pegs on the plastic piece of the cuff. Peg • Push the monitor onto the cuffand make sure it is securely fastened.
Attaching of Arm Cuff and Posture During Measurement Unfasten and open the cuff as shown in the figure, leaving the “Index” end of the cuff through the “D” ring (fig. F). Wrap the arm cuff around the upper left arm firmly so that bottom edge of the cuff is positioned about one inch above the elbow joint. Position the cuff so that the artery mark is in the middle of the arm, in line with the middle finger (fig. E). Fig. F 2~3 cm 0.8~1.2 inch Fig.
Measurement • Press the “ON/OFF/START button. • All display symbols will appear for approximately one second before the display returns to “0”. • The unit will automatically start to inflate slowly, measuring your blood pressure. During inflation, the changing values of the cuff pressure will be shown on the display. These numbers are for reference only and do not represent your final Blood Pressure reading. • When the pressure reaches your systolic blood pressure, the monitor will exhaust cuff pressure.
Subsequent Measurement When a second measurement needs to be made, the time between two measurements should be at least teb minutes. Automatic Power OFF Function If unit is left on after measurement, an “Automatic Power-OFF Function” turns the power off after approximately one minute. To continue with another measurement press the “ON/OFF/START” switch to turn the unit on. Memory Recall Function • Stores the last sixty readings in sequential order (1-60).
Description of Display Marks DISPLAY MARK CONDITION/CAUSE Blood pressure could not be measured accurately. CORRECTIVE ACTION Exhaust all air from the cuff. Reapply the cuff properly. Repeat measurement. Batteries are weak. Replace the batteries. Device malfunction. Return to Lumiscope™ Service Department.
Specifications Model No. 1095 Measuring Principle Measurement Localization Cuff Arm Circumference Range Measurement Pressure Pulse Range Pressure Accuracy Pulse Pressure Pulse Rate LCD Indication Oscillometric Method Left Upper Arm Soft Cuff 8.66 to12.6in (22 to 32 cm) 20 to 280 mmHg 40 to 180 Pulses/min.
Two Year Limited Warranty The Lumiscope™ Company, Inc., guarantees this product free from defects in material and workmanship for a period of two years from the date of purchase, except as noted below: This Lumiscope™ product warranty does not cover damage caused by misuse or abuse; the attachment of any unauthorized accessory; alteration to the product; or any other conditions whatsoever that are beyond the control of the Lumiscope™ Company, Inc.