User Guide

On/Off Button
Display Window
Flexible Probe
Battery Cover
1
2
3
5
4
Fast Read
Dual Scale Digital Thermometer
With Soft Flexible Tip
INSTRUCTIONS FOR USE MODEL 2214
Please read carefully before using ID# ACT05/03
________________________________________________________________
FEATURES
The Lumiscope 2214 Fast Read Dual Scale Di
g
ital Thermometer with Soft Flexible Tip accuratel
y
measures temperature 6 times quicker then most digital thermometers. The compact, lightweight design is
durable and waterproof and features an easy-to-read display-ideal for use by the whole family.
________________________________________________________________
PARTS DESCRIPTION
________________________________________________________________
CHANGING FROM ºC TO ºF
To change from ºC to ºF or vice versa-while the thermometer is OFF, press the on/off button once then
immediately press and hold the on/off button again until the mode changes.
________________________________________________________________
HOW TO USE
To ensure an accurate temperature readin
g
, avoid eatin
g
, drinkin
g
an
y
liquids, exercisin
g
, bathin
g
or
smoking for 15 minutes before taking a measurement.
1. Disinfect the thermometer probe with ethyl (rubbing) alcohol. Place a probe cover over the tip of the
thermometer. Press the on/off button. The display will show (or ) followed by . If
appears instead, the thermometer has malfunctioned and must be repaired or replaced.
2. The displa
y
will now read
(
or
)
with a blinkin
g
ºF
(
or ºC
)
and the unit is now read
y
for
measurement. Place the probe in the desired measurement location (oral, under arm, rectal).
3. Once the ºF (or ºC) has stopped blinking, the peak temperature has been reached and a beeper will
sound for approx. 4 seconds.
4. After reading the measurement, turn the thermometer off, dispose of the used probe cover and clean
the thermometer. If the thermometer is accidentally left on, it will automatically shut off after 10 minutes.
5. Children should alwa
y
s be supervised b
y
an adult durin
g
the measurement process. After use, the
thermometer should be stored in a safe place, out of the reach of children.
NOTE: If the measured temperature is higher or lower than the thermometer’s measuring range, the
display will read (or ) or (or ).
NOTE: Using a probe cover may result in a 0.2ºF (0.1ºC) difference from actual temperature.
________________________________________________________________
RELIABLE METHODS TO MEASURE TEMPERATURE
ORAL USE (approx. 10-20 seconds)
Place the probe tip well under the ton
g
ue. The mouth should remain closed durin
g
measurement to
ensure an accurate temperature reading. Do not bend or bite the probe while it is in the mouth. A normal
temperature by this method is 98.6ºF (37ºC).
UNDER ARM USE (approx. 15-25 seconds)
Wipe the armpit with a dry towel. Place the probe tip under the armpit and keep the arm firmly pressed
against the body during measurement to ensure an accurate temperature reading. A normal temperature
by this method is 97.6ºF (36.7ºC).
RECTAL USE (approx. 10-15 seconds)
If your doctor recommends a rectal temperature, place a probe cover over the tip of the thermometer and
lubricate the probe with a water-soluble jelly for easier insertion. Do not use petroleum jelly. Gently insert
the tip of the probe NO MORE than 1/2 inch into the rectum. STOP if you meet any resistance. Hold the
thermometer in place durin
g
measurement to ensure an accurate temperature readin
g
. A normal
temperature by this method is 99.6ºF (37.6ºC).
REMEMBER: Temperature readings vary from person to person and thermometer to thermometer. Find
your normal temperature and watch for changes. If you compare readings between two thermometers, it is
possible to have two different readings even if both thermometers are within their accuracy ranges.
Fast Read
Dual Scale Digital Thermometer
With Soft Flexible Tip
INSTRUCTIONS FOR USE MODEL 2214
________________________________________________________________
LAST TEMPERATURE RECALL
While the thermometer is OFF, press and hold the on/off button for approx. 2 seconds. The last temperature
measured will be displayed along with the letter “M” under the degree (º) sign.
_______________________________________________________________
CLEANING INSTRUCTIONS
Clean the thermometer by washing with soap and warm water or rubbing alcohol. Do not use thinners or
chemical solvents to clean. Wipe dry with a soft cloth. Do not boil or clean the probe in the dishwasher, this
will cause the unit to malfunction and will void the warranty.
________________________________________________________________
BATTERY REPLACEMENT
1. When the symbol appears the battery needs to be replaced.
2. Slide the batter
y
cover off in the direction shown. Use a toothpick or insulated probe to remove the
battery. Do not use any kind of sharp metal object to remove the battery.
3. Place a new 1.5V batter
y
in the chamber. Insert the batter
y
with the positive
(
-
)
side up and the
negative (+) side down (facing the LCD display).
4. Slide the battery cover back onto the unit and make sure it is secure.
WARNING: Dispose of old battery properly, out of the reach of children. Swallowing the battery may be
fatal. If the batter
y
is swallowed, contact hospital immediatel
y
to have it removed. Do not
dispose of the battery in a fire, it may explode.
________________________________________________________________
PRECAUTIONS
1. Prolonged high fever requires medical attention especially for young children. Contact your physician.
2. Do not drop the unit or expose to heavy shock. The unit is not shock proof.
3. Do not store the unit in direct sunlight, high temperatures, high humidity or dusty areas.
4. Do not use the thermometer if it operates erratically or if the display malfunctions.
5. Keep out of the reach of children.
6. Clean the thermometer probe before storing.
7. Do not attempt to disassemble the unit except to replace the battery.
8. If the thermometer has been stored in below-freezing temperatures, allow the thermometer to warm
naturally to room temperature before using.
________________________________________________________________
SPECIFICATIONS
Measuring Range: 90.0ºF ~ 111.9ºF (32.0ºC ~ 43.9ºC)
Accuracy: ±0.2ºF (±0.1ºC)
Power Supply: 1 Button Battery 1.5V, LR41, AG3 or similar
Weight/Dimensions: appox. 13g / 133.5mm x 22mm x 11.5mm
Ambient Operating Temperature: 50ºF ~113ºF (10ºC ~ 45ºC)
Safe-Test Alarm / Multi-Recalled Memory / Beeper
_____________________________________________________________________________________
Distributed by
Lumiscope
www.lumiscope.net
1-800-672-8293
Made and Printed in China

Summary of content (2 pages)