Find a suitable location for the Tabletop Keypad. Place
the keypad in a convenient and accessible location within
30 ft (9 m) of an RF signal repeater.
Battery Installation
1. Remove the battery cover.
Troubleshooting Guide
Symptom Probable Cause and Action
The LEDs on
a DC adapter
powered keypad
do not turn on.
Power not present at the keypad.
Verify that the DC adapter is plugged in.
Faulty DC adapter.
Replace the DC adapter.
A battery
powered keypad
does not turn on
when a button is
pressed or turns
off immediately
after the button is
pressed.
Batteries are installed incorrectly.
Install batteries as indicated in Battery Installation.
Batteries are not making contact with the battery terminals.
Adjust the batteries so that they make contact with the battery
terminals.
Dead, low, or no batteries in the keypad.
Install new batteries.
Dimmer, switch
or shade/drapery
not controlled by
Tabletop keypad.
The dimmer, switch or shade/drapery is not assigned to the keypad.
Refer to the system Setup Guide to assign devices to a keypad.
Devices are out of range.
Ensure all keypads, dimmers, switches and shades/draperies are
within 30 ft (9 m) of an RF signal repeater.
The lamp(s) is(are) burned out.
Replace lamp(s).
Either there is no power to the device or the FASS
switch is
pulled out.
Ensure that all devices are powered and all FASS switches
are pushed in.
Dimmer, switch
or shade/drapery
does not go to
desired level or
position when a
scene is selected.
The system is not programed correctly.
Refer to the system Setup Guide to program the system correctly.
Devices are out of range.
Ensure all keypads, dimmers, switches and shades/draperies
are within 30 ft (9 m) of an RF signal repeater.
All LEDs on the
keypad flash
when any button
on the keypad is
pressed.
The keypad is in Factory Settings mode and has not been programed
into a system.
Refer to the system Setup Guide to program the keypad correctly.
Note: Refer to the system Setup Guide for additional
troubleshooting suggestions.
Returning Keypads to Factory Settings
Returning a keypad to its Factory Settings will remove the
keypad from the system and erase all programming.
Step 1: Triple tap and hold any button (except the raise/
lower buttons) on a keypad. DO NOT release the
button after the third tap.
Step 2: Keep the button pressed on the third tap until all
the LEDs start to flash slowly (approximately 3
seconds).
Step 3: Immediately release the button and triple tap it
again. The status LEDs will flash quickly. When the
LEDs stop flashing, the device has been returned to
factory settings.
Warranty: For warranty information, please see
the Warranty enclosed with the product, or visit
www.lutron.com/resiinfo
Lutron, RadioRA, and the sunburst logo are registered trademarks and RadioRA 2 and FASS are trademarks of Lutron Electronics Co., Inc.
©2010 Lutron Electronics Co., Inc.
Installation Instructions
Please Read Before Installing
Tabletop Keypad
RR-T5RL, RR-T10RL, RR-T15RL
3 V or 9 V 300 mA
DC Adapter: T120-9DC-3
Input: 120 V 60 Hz 6.5 W
Output: 9 V 300 mA
Typical Power Consumption*: 0.6 W
Batteries: 2 AAA alkaline 1.5 V each
Mounting slots
Technical Assistance:
U.S.A. / Canada: 1.800.523.9466
Mexico: +1.888.235.2910
Other Countries: +1.610.282.3800
24 hours a day, 7 days a week.
Plug in
power
cord and
adapter
Optional Wall Mounting
1. Attach the wall bracket to the wall using the screws and
wall anchors provided with the keypad.
DC Adapter Installation
1. Plug the power cord into the Tabletop Keypad and the
DC adapter into an outlet.
Note: The DC adapter does NOT charge batteries.
Rechargable batteries should NOT be used with Tabletop
Keypads.
3. Replace battery cover.
Setup
To program the system refer to the system Setup Guide.
2. Install batteries as shown. Use two (2), 1.5 V AAA
alkaline batteries only.
2. Wrap excess power supply cord (if using DC adapter)
around the cord holder. Align keypad mounting slots and
snap onto the wall bracket.
Use these instructions to install the model numbers listed above. For
system setup instructions and tools visit: www.lutron.com/radiora2
Important Notes
Codes: Install in accordance with all local and national electrical codes.
Battery Power: Use only high quality AAA alkaline batteries. Battery powered
Tabletop Keypads will shut off after a short period of inactivity in order to conserve
battery power. Press any button on the Tabletop Keypad to turn it on.
Do not use rechargeable batteries. Using improperly rated batteries
could damage the keypad.
WARNING: Risk of re, explosion and burns. May result in serious injury
or death. DO NOT recharge, disassemble, crush, puncture, heat above
212 °F (100 °C) or incinerate the battery. Do not dispose of batteries
in normal household waste. Please recycle batteries, take to a battery
disposal facility, or contact your local waste disposal provider regarding
local restrictions on the disposal or recycling of batteries.
DC Adapter Power: Use only the DC adapter supplied with the keypad.
Using a DC adapter not rated for the proper specications could
damage the keypad and possibly overheat the DC adapter. Refer to the ratings
shown at the top of page.
Environment: Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C),
0 to 90% humidity, non-condensing. Indoor use only.
Cleaning: To clean, wipe with a clean damp cloth. DO NOT use any chemical
cleaning solutions.
RF Device Placement: RF dimmers, switches, keypads and shades/drapes
must be located within 30 ft (9 m) of an RF signal repeater. Remote dimmers and
switches are not required to be within a specific range.
Engraving: The Prepaid Engraving Certificate included with the keypad can be
reedeemed for a custom engraved button / faceplate kit. To order an engraved
button / faceplate kit please follow the instructions located at
www.lutron.com/buttons
Note: To avoid operation issues, Lutron recommends that the keypad, DC adapter
and wall bracket should not be painted.
NOTICE:
Typical Power Consumption test conditions: all backlights on medium intensity,
nightlight mode enabled , six LEDs on (two presets active per column), keypad
powered by the 9 V adapter supplied.
*
NOTICE: