ALL PROGRAMMING IS OPTIONAL
Programming is not required for default functionality
Reset Factory Defaults
Test Mode
Note: It may be necessary to reset the device to factory default settings. Before beginning, ensure the device is
connected and powered.
Note:
Any associations or programming previously set up with the sensor dimmer / switch will be erased and will
need to be re-programmed after resetting to factory defaults.
1. Rapidly tap
T
three times and hold on the fourth until the lights begins to flash rapidly; release
T
.
2.
Within 1 second of releasing
T
, rapidly tap
T
three times again and the lights will flash slowly indicating that the
device has been reset to factory defaults.
Test mode has a short timeout (< 15 seconds) that will test the coverage of the sensor with the current settings.
1. Wait at least 2 minutes after power is turned on.
2. Press and hold
T
until the PIR lens flashes (about 3 seconds).
3. The device will exit test mode after 5 minutes of inactivity or when any button is pressed.
The sensor LED behind the lens will turn on while occupied and turn off while vacant.
Vive Sensor Dimmer / Switch
Part of the Vive System
For set-up, programming, and troubleshooting with a
Vive system, please refer to the installation instructions
included with the Vive hub or at www.lutron.com
Lutron Electronics Co., Inc. 7200 Suter Road
Coopersburg, PA 18036-1299 USA
Lutron, Pico, Maestro, and Vive are trademarks of Lutron Electronics Co., Inc. registered in the U.S. and other countries. Radio Powr Savr is a trademark of Lutron Electronics Co., Inc.
App Store is a service mark of Apple, Inc. Android and Google Play are trademarks of Google LLC. iOS is a trademark or registered trademark of Cisco in the U.S. and other countries and is used under license.
© 2018 Lutron Electronics Co., Inc.
Customer Assistance | 1.844.LUTRON1 U.S.A. / Canada | +1.888.235.2910 Mexico | +1.610.282.3800 Others | www.lutron.com/support
Symptom Possible Causes and Solutions
Lights can not be manually
turned ON or OFF with
the newly installed sensor
dimmer / switch.
• Verify proper wiring. Neutral must be connected for product to
function properly.
• Wait 10 seconds and try to turn ON or OFF again.
Wireless device will not
associate to a sensor
dimmer / switch.
• Wireless device is out of range.
• Wireless performance is being affected by the physical setup
of the space. See Wireless Communication section for more
information.
Not all of the sensor
modes are available when
programming.
• Sensor modes are limited for vacancy only models
(MRF2S-8SDV010 and MRF2S-8SSV).
• Device may be part of a Vive system.
Lights do not automatically
turn ON when space is
occupied.
• Sensor Mode is set to Vacancy (Manual-ON / Auto-OFF).
• The sensor dimmer / switch may be a vacancy only model
(MRF2S-8SDV010 and MRF2S-8SSV).
• The room may be too bright for the current light level setting for
Fixed ALD Level.
Driver / ballast cannot be
dimmed up or down.
Lens flashes when trying to
dim the lights.
• Verify proper connection of gray and purple wires.
• Driver / ballast does not comply with ANSIC137.1-201x 0–10V.
See www.lutron.com/TechnicalDocumentLibrary/048687.pdf
Troubleshooting www.lutron.com/support
1
Sensor Mode is locked as “Vacancy” in vacancy only models (MRF2S-8SDV010 and
MRF2S-8SSV).
2
Available in standalone. Not available when used in a Vive system.
3
Only available with the sensor dimmer. Not available with sensor switch.
4
Available in standalone. When the device is used in a Vive system, these adjustments are
only available via the Vive software.
5
Learning ALD (Ambient Light Detection): Lights remain off if enough natural light is present.
If the lights turn on and the user does not want that much light, they can tap
T
within
5seconds of entering the space. Similarly, if the lights do not turn on when entering a space
and the user wants more light, they can tap
T
within 5seconds of entering the space.
Over time, the sensor will learn the preferred light level.
6
Fixed ALD: Lights turn on only when there is less than a set (locked) amount of natural light
available. The level can be adjusted in “Fixed ALD Level” settings.
7
This setting will override the sensor mode of the Radio Powr Savr occupancy / vacancy
sensor.
IL
Indicator LEDs
2
Tapswitch
(on / off)
M
P
Sensor LED
(behind lens)
See Test Mode
section.
Sensor
mode
4, 7
Timeout
4
M
PIR lens
Sensor dimmer shown
PIR
sensitivity
4
Raise
3
Maestro
LEDs
Lower
3
Alt
2
L
R
ML
Alt
High-End Trim
3, 4
1. Press and hold
T
and
R
until a
ML
flashes (about 6 seconds).
2. Press and hold
R
until the top
ML
is lit and the lights stop brightening.
3. Tap
L
until the desired level is achieved. Press and hold
T
until the
ML
stops flashing (about 6 seconds).
Low-End Trim
3, 4
1. Press and hold
T
and
L
until a
ML
flashes (about 6 seconds).
2. Press and hold
L
until the bottom
ML
is lit and the lights stop dimming.
3. Tap
R
until the lights are on and stable (no flickering) and the desired level is achieved. Press and hold
T
until the
ML
stops flashing (about 6 seconds).
Occupancy Level
3, 4
The level which the sensor dimmer turns on when motion is detected. This level is adjustable from 1% to 100% within the range of
the low-end and high-end trims.
1. Press and hold
M
and
R
until a
ML
flashes (about 6 seconds).
2. Tap
R
or
L
until desired level is achieved.
3. Press and hold
M
until the
ML
stops flashing (about 6 seconds).
Vacancy Level
3, 4
The level which the sensor dimmer dims or turns off when motion has not been detected for the timeout period. This level is
adjustable from 1% to 100% within the range of the low-end and high-end trims.
1. Press and hold
M
and
L
until a
ML
flashes (about 6 seconds).
2. Tap
R
or
L
until desired level is achieved.
3. Press and hold
M
until the
ML
stops flashing (about 6 seconds).
Fixed ALD Level
2
(MRF2S-8SD010 and MRF2S-8SS only)
The light level that determines when a sensor will turn lights on or keep lights off when detecting occupancy. This setting only affects
sensors set to “Fixed ALD” mode.
1. Press and hold
M
and
Alt
until an
IL
flashes (about 3 seconds).
2. The “Fixed ALD” light level will now be displayed by the
IL
. Tap
M
to cycle to the desired setting.
3. Press and hold
M
until the
IL
turns solid (about 3 seconds).
Walk-through Mode
2
Allows the lights to turn off before the Timeout has expired if occupancy is detected only briefly.
1. Press and hold and
Alt
until an
IL
flashes (about 3 seconds).
2. The walk-through setting will now be displayed by the
IL
. Tap
Alt
to cycle to the desired setting.
3. Press and hold
Alt
until the
IL
turns solid (about 3 seconds).
Electronic Off
2
Affects how the lights are turned off. If enabled, the driver will still have power but the lights will be turned off. If disabled, the driver will
not have power and the lights will be turned off.
1. Press and hold and
M
until an
IL
flashes (about 3 seconds).
2. The electronic off setting will now be displayed by the
IL
. Tap
M
to cycle to the desired setting.
3. Press and hold
M
until the
IL
turns solid (about 3 seconds).
Change Basic Settings
Change Advanced Settings
Check Current Settings
2
1. Press and hold the desired programming button ( ,
M
, or
P
) until an
IL
flashes (about 3seconds).
2. Tap the same programming button to cycle to your desired setting.
3. Press and hold the same programming button until the
IL
turns solid (about 3seconds). The setting has been saved.
For complete programming options and additional information, visit www.lutron.com/TechnicalDocumentLibrary/048687.pdf
Timeout: 15 minutes
Sensor Mode: Occupancy (Auto-On / Auto-Off)
1
PIR Sensitivity: High
Occupied Level: 100%
Vacancy Level: 0%
Fixed ALD Level: Low (when in Fixed ALD mode)
Default Settings
To display the current settings, tap the Timeout ( ), Sensor Mode (
M
),
or PIR Sensitivity (
P
) button. The indicator LED (
IL
) that corresponds to
the current setting will illuminate.
T
P
Timeout
4
Sensor Mode
1
(determines when lights turn on)
PIR Sensitivity
4
m30
15
5
1
Occ
Lrn
Fixd
Vac
Mode
Hi
Med
Low
Min
PIR
Alt
m30
15
5
1
Occ
Lrn
Fixd
Vac
Mode
Hi
Med
Low
Min
PIR
Alt
m30
15
5
1
Occ
Lrn
Fixd
Vac
Mode
Hi
Med
Low
Min
PIR
Alt
m30
15
5
1
Occ
Lrn
Fixd
Vac
Mode
Hi
Med
Low
Min
PIR
Alt
100%
45%
100%
55%
1%
1%
30 minutes
15 minutes
5 minutes
1 minute
Occupancy (Auto-ON / Auto-OFF)
4
Occupancy with Learning ALD
2, 5
Occupancy with Fixed ALD
2, 6
Vacancy (Manual-ON / Auto-OFF)
4
High
Medium
Low
Minimum
High (turn ON lights unless area has a lot of light)
Medium
Low
Minimum (turn ON lights only when room is dark)
(unused)
(unused)
Disabled
Enabled
(unused)
(unused)
Enabled
Disabled
0%
100%
Default settings in bold