Installation Guide

INSTALLATION
Specifictions
Optical Performance
Delivered Lumen Output
Beam Angle
(1"/ 25.4mm recess)
9W 13W 18W
15° beam low glare 650 lm 882 lm 1092 lm
25° beam, low glare 623 lm 845 lm 1046 lm
40° beam, low glare 569 lm 772 lm 955 lm
60° beam, low glare 561 lm 760 lm 941 lm
15° beam high output 682 lm 928lm 1148 lm
25° beam, high output 678 lm 923 lm 1142 lm
40° beam, high output 646 lm 878 lm 1087 lm
60° beam, high output 630 lm 857 lm 1061 lm
CRI (Ra)3 >90 (R9>90) 2400K5000K TYP
Lumen Maintenance 50,000 hours to L70 @ 25˚C T
A
Color Spatial Uniformity <2 MacAdam ellipses across
field angle
Color Point Range 1400˚K10,000˚K, Fully
Saturated,  Pastel
Equivalent Traditional Lamp 75W halogen
Dimming Range 0.1100% lm
Power Consumption D3.13 13 W
D3.18 18 W
Voltage*
120 60 Hz
220277 60 Hz
220277 50 Hz
Power Factor >0.9
Current 150 mA Max
Delivered Ecacy
Beam Angle
(1"/ 25.4mm recess)
9W 13W 18W
15° beam low glare 72 lm/W 68 lm/W 61 lm/W
25° beam, low glare 69 lm/W 65 lm/W 58 lm/W
40° beam, low glare 63 lm/W 59 lm/W 53 lm/W
60° beam, low glare 62 lm/W 58 lm/W 52 lm/W
15° beam high output 76 lm/W 71 lm/W 63 lm/W
25° beam, high output 75 lm/W 71 lm/W 62 lm/W
40° beam, high output 72 lm/W 68 lm/W 59 lm/W
60° beam, high output 70 lm/W 66 lm/W 58 lm/W
Surge Protection 2.5 KV
Control Protocol KetraNet Mesh
Environmental
Operating Temperature 0  40 °C
Storage Temperature -20  80 °C
Humidity 0  95%, Non-condensing
Certification UL, cUL, RoHS, FCC Class B
Location UL Damp Location, UL Wet
Location Available with Lens Trim
Electrical
Mounting Options Hanger Bars / Butterfly Brackets
Field Replaceable Optics Yes
Field Replaceable
Light Engine
Yes
Field Replaceable
Power Supply
Yes
Additional Optic Lens Holder 2.5”/63.5 mm Lens, ⁄”/3.175 mm Thick
Additional Trim Lens Holder 2.75”/69.85 mm Lens, ⁄”/3.175 mm Thick
Housing Material Powder Coated Steel, Polymer
Lens Material Glass
Dimensions
Ceiling Hole Diameter 4”/ 101.6 mm Flanged,
5.5”/ 139.7 mm Mud-In
Trim Outside Diameter 4.62”/ 117.348 mm
Trim Inside Diameter 3.75”/ 95.25 mm
Trim Thickness ⁄"/ 1.5875 mm
Optics Outside Diameter 2.5”/ 63.5 mm
Trim Depth 1"/ 25.4 mm
Ceiling Thickness 0.625” – 1.5”/ 15.875  38.1 mm
Emitter Vertical Adjustment
(tool-free)
0.75”/ 19.05 mm
Housing Vertical Adjustment
via Butterfly Bracket
1.75”/ 44.45mm
Housing Height 3.50”/ 88.9 mm
Housing Length 18.38”/ 466.852 mm
Housing Width 10.07”/ 255.778 mm
* Ketra lighting products should not be connected to, or directly controlled by, AC mains line voltage dimmers. These types of dimmers may
also be referred to as phase cut, triac, forward-phase, reverse-phase, ELV, or MLV dimmers. Ketra's lighting products should only be controlled
via our digital control architecture. Ketra does not recommend switching power on/o to Ketra lighting products via relays, contactors, or
manual toggle switches. When the lighting products are disconnected from power they cannot respond to digital commands from control
devices. This could confuse end users as the lighting may be in a state that is inconsistent with the control devices. Please refer to our controls
products installation guides for more information.
6|D3 INSTALLATION GUIDE
P/N 040444 Rev D
© 2019 Ketra, Inc. All rights reserved