Installation Guide

Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 10/10 P/N 033-206 Rev. A
Fan-Speed Controls
Limited Warranty
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty
service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF
MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE
COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE,
OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL
OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR
IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL
NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specic legal rights, and you may have other rights which vary from state to state. Some states do not allow the
exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations
may not apply to you. NEC is a registered trademark of National Fire Protection Association, Quincy, Massachusetts. Lutron is a registered
trademark of Lutron Electronics Co., Inc. © 2010 Lutron Electronics Co., Inc.
FS-5F: 5 A 120 V 60Hz
FSQ-2F: 1.5 A 120 V 60Hz
LTFSQ-2H: 1.5 A 120 V 60Hz
LTFSQ-FH: 1.5 A 120 V 60Hz
Important Notes
Please read before installing.
1. CAUTION: To avoid overheating and possible damage to other equipment, do not
use to control receptacles, uorescent lighting xtures, or transformer-supplied
appliances.
2. Set multi-speed fans to their highest setting before installing controls.
3. When no "ground means" exists within the wallbox, then NEC® 2008, 404.9
exception to (b) allows a control without a ground connection, to be installed as a
replacement. For this type of installation, cap or remove the green control ground
wire. A control installed under this exception (NEC 404.9 exception to (b)) must be
provided with a plastic, noncombustible, UL listed wallplate.
4. Do not use control with a fan and light that operate with the same switch.
5. For new installations, wire a test switch before installing the control.
6. Use FSQ-2F and SFSQ-F controls with a ceiling paddle fan only. Use only one ceiling
paddle fan per control.
7. Use FS-5F controls only with fans marked "Suitable for use with solid-state fan-
speed controls."
8. Do not wire an FSQ-2F, SFSQ-F or SFSQ-F-HO in a circuit with a GFCI breaker/
receptacle.
9. Controls may feel warm to the touch during normal operation.
10. Install in accordance with all national and local electrical codes.
11. Clean control with a soft damp cloth only. Do not use any chemical cleaners.
Multi-Unit Installations
When combining controls in a wallbox, remove all inner side sections before wiring
(see below). Use pliers to bend each side section up and down until it breaks off. FS-5F
controls require reduction of their capacity. Refer to chart below for maximum capacity.
FSQ-2F, SFSQ-F and SFSQ-F-HO controls do not require capacity reduction.
Important Wiring Information
Twist wire connector
tight.
Be sure no bare wire
is exposed.
When making wire connections, follow the recommended strip lengths and combinations
for the supplied wire connectors. Note: Wire connectors provided are suitable for copper
wire only. For aluminum wire, consult an electrician.
Small:
Strip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm²) wire
Strip insulation 1/2 in (13 mm) for 16 or 18 AWG
(1.0 mm² or 0.75 mm²) wire
Use to join one 14 AWG (1.5 mm²) supply wire with one
16 or 18 AWG (1.0 mm² or 0.75 mm²) control wire.
Large:
Strip insulation 1/2 in (13 mm) for 10, 12 or 14 AWG
(4, 2.5 or 1.5 mm²) wire
Strip insulation 5/8 in (16 mm) for 16 or 18 AWG
(1.0 mm² or 0.75 mm²) wire
Use to join one or two 12 or 14 AWG (2.5 or 1.5 mm²)
supply wires with one 10, 12, 14, 16, or 18 AWG (4, 2.5,
1.5, 1.0 or 0.75 mm) control wire.
Small
Large
Align control and
tighten screws.
ON
OFF
ON
OFF
ON
OFF
Start screws.
5 Wire the control:
•Connectthegreengroundwireonthe
control to the green or bare copper
ground wire in the wallbox (see
Important Note 3).
•Connecttheblackwireonthecontrol
to either of the wires removed from
the switch.
•Connecttheremainingwireonthe
control to the remaining wire removed
from the switch.
Green
Black
Ground
Black
6 Mount and align control. Install wallplate.
7 Turn power ON.
Fan
BlackBlack
Ground
Green
Hot
Neutral
120 V
60Hz
Fan Control
SFSQ-F: 1.5 A 120 V 60Hz
SFSQ-F-HO: 2 A 120 V 60Hz
Installation
For installations involving more than one control in a wallbox, refer to Multi-Unit
Installations before beginning.
Model
Number
No Sides
Removed
1 Side
Removed
2 Sides
Removed
FS-5F 5 A 4 A 3 A
Technical Assistance
If you have questions concerning the installation or operation of this product,
call the Lutron Technical Support Center. Please provide exact model number
when calling.
U.S.A. and Canada (24 hrs/7days)
1.800.523.9466
México
+1.888.235.2910
Other countries 8am – 8pm ET
+1.610.282.3800
Fax +1.610.282.6311
http://www.lutron.com
Lutron Technical Support Center 1.800.523.9466 24 hrs / 7 days www.lutron.com
English
Do Not Remove
Outside Sections
Inside Sections Are
Removed From Each Control
Side Sections Are Removed From
Both Sides Of Middle Control
1 Turn power OFF at circuit breaker or remove fuse.
ON
OFF
ON
OFF
ON
OFF
WARNING: Shock Hazard. May result
in serious injury or death. Turn off
power at circuit breaker before
installing the unit.
2 Remove switch mounting screws. Pull switch from wall.
3 Verify your application.
Switch must have two insulated wires connected to two screws and a bare copper
or green wire connected to a green screw. Note: Do not connect to a light xture.
Ground
(Bare Copper or Green WIre)
4 Disconnect switch wires.
Backwired:
Insert screwdriver. Pull
wire out.
Terminal Screws:
Turn screws to loosen.
OR
Important Note:
Your wall switch may have two wires attached to the same screw (see illustrations below
for examples). Tape these two wires together before disconnecting. When wiring, connect
wires to the Dimmer the same way they were connected to the switch.