Fan/Light Controls
Rated at 120 V~ 60 Hz
AY2-LFSQ: Fan: 1.5 A, Light: 300 W S2-LF: Fan: 2.5 A, Light: 300 W
TG2-LFSQ: Fan: 1.5 A, Light: 300 W S2-LFSQ: Fan: 1.5 A, Light: 300 W
S2W-LFSQ: Fan: 1.5 A, Light: 300 W
Important Notes
Please read before installing.
1. CAUTION: To avoid overheating and possible damage to other
equipment, do not use to control receptacles, fluorescent lighting fix-
tures, or transformer-supplied appliances.
2. Controls require separate wires in the wallbox for fan and light.
3. For new installations, wire a test switch before installing the control.
4. Set multispeed fans to their highest setting before installing controls.
5. Use an AY2-LFSQ, S2-LFSQ, S2W-LFSQ or TG2-LFSQ control with a
ceiling paddle fan only. Use only one ceiling paddle fan per control.
6. Use an S2-LF only with fans marked "Suitable for use with solid-state
fan-speed controls."
7. Do not wire an AY2-LFSQ, S2-LFSQ, S2W-LFSQ or TG2-LFSQ in cir-
cuit with a GFCI breaker/receptacle.
8. Controls may feel warm to the touch during normal operation.
9. When no “grounding means” exist within the wallbox then the NEC
®
2005, Article 404-9 allows a dimmer without a grounding connection
to be installed as a replacement, as long as a plastic, noncombustible
wallplate is used. For this type of installation, cap or remove the
green ground wire on the dimmer and use an appropriate wallplate
such as Lutron’s Claro
® series wallplates.
10. Install in accordance with all national and local electrical codes.
11. Clean control with a soft damp cloth only. Do not use any chemical
cleaners.
Multi-Unit Installations
When combining controls in a wallbox, remove all inner side sections
before wiring (see below). Use pliers to bend each side section up and
down until it breaks off. S2-LF controls require reduction of their capacity.
Refer to chart below for maximum capacity. Other fan-speed controls
(-LFSQ) do not require capacity reduction.
Tag the wire that is connected to the
feed side of the switch (the side with
the break-off fin).
Break-off fin
To Fan
Feed (Live)
Turn screws to loosen.
To Light
Align control and
tighten screws.
ON
OFF
ON
OFF
ON
OFF
Start screws.
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after
purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg,
PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF
MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE
COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE,
ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER
INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARIS-
ING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF
THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some
states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an
implied warranty may last, so the above limitations may not apply to you.
This product may be covered by Mexican patent 168,884 and one or more of the following U.S. patents:
4,835,343; 4,835,816; 5,191,971; 5,262,678; 5,359,231; 5,637,930; DES 342,234 and corresponding foreign
patents. Lutron is a registered trademark of Lutron Electronics Co., Inc. NEC is a registered trademark of the
National Fire Protection Association, Quincy, Massachusetts. © 2006 Lutron Electronics Co., Inc.
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center
. Please provide exact model number when calling.
1-800-523-9466 (U.S.A., Canada, and the Caribbean)
Other countries call +1-610-282-3800
Fax +1-610-282-3090 Internet: www.lutron.com
Important Wiring Information
Twist wire connector
tight.
Be sure no bare wire
is exposed.
When making wire connections, follow the recommended strip lengths and combinations
for the supplied wire connectors. Note: Wire connectors provided are suitable for
copper
wire only.
For aluminum wire, consult an electrician.
Small:
Strip insulation 3/8" (10 mm) for 14 AWG wire
Strip insulation 1/2" (13 mm) for 16 or
18 AWG wire
Use to join one 14 AWG supply wire with one
16 or 18 AWG control wire.
Large:
Strip insulation 1/2" (13 mm) for 10, 12 or
14 AWG wire
Strip insulation 5/8" (16 mm) for 16 or
18 AWG wire
Use to join one or two 12 or 14 AWG supply
wires with one 10, 12, 14, 16, or 18 AWG
control wire.
Small
Large
No Sides 1 Side 2 Sides
Model Number Load Removed Removed Removed
S2-LF Fan/Light 2.5 A/300 W 2.1 A/250 W 1.7 A/200 W
ON
OFF
ON
OFF
ON
OFF
Installation
For installations involving more than one control in a wallbox, refer to
Multi-Unit Installations before beginning.
WARNING: Turn power OFF at circuit breaker or remove fuse.
Remove switch mounting screws. Pull switch from wall.
Verify application. This dimmer mounts in a single-gang wallbox
and independently controls a ceiling paddle fan and a light with
each slider. Independent wire must be provided for the fan and
light in addition to the feed wire (Live).
Disconnect switch wires.
Wire the control.
Connect the green ground wire
on the control to the bare cop-
per or green ground wire in the
wallbox.
Connect the black wire on the
control to the tagged wallbox
wire removed from the switch
(feed wire from the circuit
breaker or fuse box).
Connect the yellow wire on the
control to the wire leading to the
fan.
Connect the red wire on the
control to the wire leading to the
light.
Mount and align control. Install wallplate.
Turn power ON.
120 V~
60 Hz
Tag
P/N 033-038
P/N 033-038
Yellow
TAG
Red
Black
Green
Ground
Green
Ground
Yellow
Red*
Black
Live
Neutral
Light
Fan
*Cap of Red wire
if no light is used.
11
22
33
44
77
66
55
Do Not Remove
Outside Sections
Inside Sections Are
Removed From Each
Control
Side Sections Are
Removed From Both
Sides Of Middle Control
Break
Side Sections
Lutron Technical Support Center 1-800-523-9466 24 hrs / 7 days www.lutron.com