Installation Manual

Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 2/10 P/N 030-1277 Rev. A
ON
OFF
ON
OFF
ON
OFF
Align control and
tighten screws.
ON
OFF
ON
OFF
ON
OFF
Start screws.
Single Pole/3-Way
Quiet Fan-Speed Controls
AYFSQ-F: 1.5 A 120 V 60 Hz
DVFSQ-F: 1.5 A 120 V 60 Hz
DVFSQ-F-HO: 2 A 120 V 60 Hz
DVSCFSQ-F: 1.5 A 120 V 60 Hz
DVSCFSQ-F-HO: 2 A 120 V 60 Hz
LGFSQ-F: 1.5 A 120 V 60 Hz
LGFSQ-F-HO: 2 A 120 V 60 Hz
LXFSQ-F: 1.5 A 120 V 60 Hz
LXFSQ-F-HO: 2 A 120 V 60 Hz
TGFSQ-F: 1.5 A 120 V 60 Hz
Important Notes
Please read before installing.
1. CAUTION: To avoid overheating and possible damage to other equipment, do not use to
control receptacles, fluorescent lighting fixtures, or transformer-supplied appliances.
2. Do not use control with a fan and light that operate with the same switch.
3. When no
grounding means” exist within the wallbox then the NEC® 2008, Article 404.9
allows a control without a grounding connection to be installed as a replacement, as long
as a plastic, noncombustible wallpate is used. For this type of installation, cap or remove
the green ground wire on the control and use an appropriate wallplate such as Claro® or
Fassada® series wallplates by Lutron
®.
4. Use control with a ceiling paddle fan only. Use only one ceiling paddle fan per control.
5. For new installations, wire a test switch before installing the control.
6. Set multi-speed fans to their highest setting before installing controls.
7. Do not wire controls in a circuit with a GFCI breaker/receptacle.
8. Use only one control in a 3-way circuit.
9. Install in accordance with all national and local electrical codes.
10. Clean control with a
soft damp cloth only
. Do not use any chemical cleaners.
Multi-Unit Installations
When combining controls in one wallbox, remove all inner side sections before wiring
(see below). Use pliers to bend each side section up and down until it breaks off.
Reduction of control capacity is not required.
Remove Switch Mounting Screws. Pull Switch from Wall.
Verify the Application.
Disconnect Switch Wires.
Ground
(Bare Copper or Green Wire)
Backwired:
Insert screwdriver. Pull
wire out.
Terminal Screws:
Turn screws to
loosen.
OR
Mount and Align Control. Install Wallplate.
Turn Power ON.
Single-Pole:
Insulated wires connected to
two screws of the same color.
See step 5a.
3-Way:
Insulated wires connected to three screws. TAG
insulated wire connected to the different-colored
(not green) screw or screw labeled COMMON. See
step 5b.
Different-colored screw
(Common)
OR
Ground
(Bare Copper or
Green WIre)
Tag
Wire the Control. Single-Pole Circuit:
Connect the green ground wire on the
control to the green or bare copper
ground wire in the wallbox (see
Important Note 3).
Connect the black wire on the control
to either of the wires removed from
the switch.
Connect the red wire on the control
to the remaining wire removed from
the switch.
Using a wire connector, cap off the
red/white wire. This wire is not used in
a single pole circuit.
Wire the Control. 3-Way Circuit:
Connect the green ground wire on the
control to the green or bare copper
ground wire in the wallbox (see
Important Note 3).
Connect the black wire on the control to
the tagged wire removed from the
different-colored (not green) screw on
the switch.
Connect the red wire on the control to
either of the remaining wires removed
from the switch.
Connect the red/white wire on the
control to the remaining wire removed
from the switch.
Or
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after
purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg,
PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF
MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE
COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE,
OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL
OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR
IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL
NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some
states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an
implied warranty may last, so the above limitations may not apply to you.
This product may be covered by one or more of the following U.S. patents: 5,191,971; 5,207,317; 5,262,678;
5,637,930; 5,359,231; 6,005,308; D558,151, and corresponding foreign patents.
NEC is a registered trademark
of the National Fire Protection Association, Quincy, Massachusetts.
Lutron, Claro, and Fassada are registered
trademarks of Lutron Electronics Co., Inc. © 2010 Lutron Electronics Co., Inc.
Technical Assistance
For questions concerning the installation or operation of this product, call the
Lutron Technical Support
Center
. Please provide exact model number when calling.
1.800.523.9466 (U.S.A., Canada, and the Caribbean) +1.888.235.2910 (México)
+1.610.282.3800 (Other Countries)
Fax +1.610.282.6311 Internet: www.lutron.com
Important Wiring Information
Twist wire
connector tight.
Be sure no bare
wire is exposed.
When making wire connections, follow the recommended strip lengths and combinations
for the supplied wire connectors. Note: Wire connectors provided are suitable for
copper
wire only.
For aluminum wire, consult an electrician.
Small
Large
Green
or Bare
Ground
Red/
White
Red
Black
Tag
Black
Ground
Red/W
hite
Red
Green
or Bare
Installation
For installations involving more than one control in a wallbox, refer to
Multi-Unit Installations before beginning.
1 Turn Power OFF at Circuit Breaker or Remove Fuse.
P/N 030-1277
120 V~
60 Hz
120 V~
60 Hz
11
22
33
Lutron Technical Support Center 1.800.523.9466 24 hrs / 7 days www.lutron.com
44
Important Note: Your wall switch may have two wires attached to the same screw (see illustra-
tions below for examples). Tape these two wires together before disconnecting. Connect both wires
to the dimmer wire in step 5.
One wire in the back-
wired hole and one to
the screw.
One continuous wire to
the screw.
77
66
55bb
55aa
Live Black
Red
Red/White
Green
Ground
Fan
Neutral
Live Black
Red
Red/White
Green
Ground
Fan
Neutral
3-Way
Switch
English
WARNING: Shock Hazard. May result in serious
injury or death. Turn of power at circuit breaker
before installing the unit.
Small:
Strip insulation 3/8 in (9.5 mm) for 14 AWG (1.5 mm
2
) wire.
Strip insulation 1/2 in (13 mm) for 16 or 18 AWG
(1.0 or 0.75 mm
2
) wire.
Use to join one 14 AWG (1.5 mm
2
) supply wire with
one 16 or 18 AWG (1.0 or 0.75 mm
2
) control wire.
Large:
Strip insulation 1/2 in (13 mm) for 10-14 AWG
(6-1.5 mm
2
) wire.
Strip insulation 5/8 in (16 mm) for 16 or 18 AWG
(1.0 or 0.75 mm
2
) wire.
Use to join one or two 12 or 14 AWG (2.5 or 1.5 mm
2
)
supply wires with one 10-18 AWG (6-0.75 mm
2
) control wire.
Do not remove
outside sections
Break Side Sections
Inside sections are
removed from each
control
Side sections are removed
from both sides of middle
control