Specification Sheet
USB receptacles
• Includes two USB ports
• Ports are rated for a minimum of
10,000 insertions and removals
• Includes 1-gang wallplate
GFCI receptacles
• Self-testing technology
allows GFCI to automatically
check proper operation every
30seconds
• LEDs indicate status of GFCI
protection function
• Press reset button to reset
GFCI after circuit interruption
•
Includes 1-gang wallplate
Receptacles
15 A 125 V NTR-15-XX
1
20 A 125 V NTR-20-XX
1
Tamper-resistant receptacles*
15 A 125 V NTR-15-TR-XX
1
20 A 125 V NTR-20-TR-XX
1
Isolated ground receptacles*
15 A 125 V NTR-15-IG-OR-XX
1
20 A 125 V NTR-20-IG-OR-XX
1
Tamper-resistant USB receptacles*
15 A 125 V NTR-15-UBTR-XX
1
Tamper-resistant, self-testing GFCI receptacles*
15 A 125 V, GFCI NTR-15-GFST-XX
1
20 A 125 V, GFCI NTR-20-GFST-XX
1
Receptacles
• Includes 1-gang wallplate
Isolated ground receptacles
• Receptacle is orange
for easy ID and circuit delineation
• Model number color code is for
wallplate only
• Includes 1-gang wallplate
XX
1
: Architectural matte color codes
(1-gang wallplate included)
* Metal and glass finishes are only available as
separate wallplates.
XX
1
: Architectural matte color codes
(1-gang wallplate included)
XX
2
: Available in White (WH) and Brown (BR)
* Metal and glass finishes are only available as
separate wallplates.
Receptacles for dimming use
• Duplex for dimming both
connected loads
• Projecting nubs prevent standard
plugs from being used
• Requires replacement plug for
dimming table and floor lamps
• Includes 1-gang wallplate
• Tamper-resistant
shutter mechanism
Half dimming, tamper-resistant receptacles*
15 A 120/125 V NTR-15-HDTR-XX
1
20 A 120/125 V NTR-20-HDTR-XX
1
Dual dimming, tamper-resistant receptacles*
15 A 120/125 V NTR-15-DDTR-XX
1
20 A 120/125 V NTR-20-DDTR-XX
1
Receptacles for half dimming use
• Top half for dimming
• Projecting nub prevents standard
plug from being used
• Requires replacement plug for
dimming table and floor lamps
• Bottom half is a general use
receptacle and will fit standard
duplex plugs
• Includes 1-gang wallplate
• Tamper-resistant
shutter mechanism
Important notes
•
Receptacles and plugs for dimming use are UL
Listed for use with all Lutron wallbox dimmers
included in this catalog.
•
If there is only one electrical feed to the receptacle,
then the duplex DFDU must be used.
•
If the hot and dimmed hot feeds to the split
duplex HFDU are supplied from different circuits
or split-wired, with separate switch-legs, a means
to simultaneously disconnect these circuits must
be provided at the panel board where they
originate (NEC 210.7(C) 2002 Edition). A 2-pole
circuit breaker or two single-pole circuit breakers
with an approved handle tie can be used to
accomplish this simultaneous disconnect. Feed-
through dimming panels, which are those without
breakers, are recommended when using the HFDU.
•
For more information on dimming lamps, consult
Lutron Application Note #109, Guide to Dimming
Portable Lamps via Receptacles, at
lutron.com/applicationnotes.
Replacement dimming plugs
120/125 V RP-FDU-10-XX
2
UL/CSA/NOM regulatory approvals
Replacement plugs for dimming
• This plug required for use with
Lutron receptacles for dimming
use—plug will work in standard
receptacle
• Easily replaces the existing plugs
on lamps
74
75
lutron.com/specificationguide | 1.800.523.9466 | | 1.800.523.9466 | lutron.com/specificationguide
ARCHITECTURAL
WALLPLATE
OPENING
ARCHITECTURAL
WALLPLATE
OPENING
Volume 1 P/N 367-1746 REV G Volume 1 P/N 367-1746 REV G
Architectural wallplates and accessories Architectural wallplates and accessories