Specification Sheet

USB receptacles
Includes two USB ports
Ports are rated for a minimum of
10,000 insertions and removals
Includes 1-gang wallplate
GFCI receptacles
Self-testing technology
allows GFCI to automatically
check proper operation every
30seconds
LEDs indicate status of GFCI
protection function
Press reset button to reset
GFCI after circuit interruption
Includes 1-gang wallplate
Receptacles
15 A 125 V NTR-15-XX
1
20 A 125 V NTR-20-XX
1
Tamper-resistant receptacles*
15 A 125 V NTR-15-TR-XX
1
20 A 125 V NTR-20-TR-XX
1
Isolated ground receptacles*
15 A 125 V NTR-15-IG-OR-XX
1
20 A 125 V NTR-20-IG-OR-XX
1
Tamper-resistant USB receptacles*
15 A 125 V NTR-15-UBTR-XX
1
Tamper-resistant, self-testing GFCI receptacles*
15 A 125 V, GFCI NTR-15-GFST-XX
1
20 A 125 V, GFCI NTR-20-GFST-XX
1
Receptacles
Includes 1-gang wallplate
Isolated ground receptacles
Receptacle is orange
for easy ID and circuit delineation
Model number color code is for
wallplate only
Includes 1-gang wallplate
XX
1
: Architectural matte color codes
(1-gang wallplate included)
* Metal and glass finishes are only available as
separate wallplates.
XX
1
: Architectural matte color codes
(1-gang wallplate included)
XX
2
: Available in White (WH) and Brown (BR)
* Metal and glass finishes are only available as
separate wallplates.
Receptacles for dimming use
Duplex for dimming both
connected loads
Projecting nubs prevent standard
plugs from being used
Requires replacement plug for
dimming table and floor lamps
Includes 1-gang wallplate
Tamper-resistant
shutter mechanism
Half dimming, tamper-resistant receptacles*
15 A 120/125 V NTR-15-HDTR-XX
1
20 A 120/125 V NTR-20-HDTR-XX
1
Dual dimming, tamper-resistant receptacles*
15 A 120/125 V NTR-15-DDTR-XX
1
20 A 120/125 V NTR-20-DDTR-XX
1
Receptacles for half dimming use
Top half for dimming
Projecting nub prevents standard
plug from being used
Requires replacement plug for
dimming table and floor lamps
Bottom half is a general use
receptacle and will fit standard
duplex plugs
Includes 1-gang wallplate
Tamper-resistant
shutter mechanism
Important notes
Receptacles and plugs for dimming use are UL
Listed for use with all Lutron wallbox dimmers
included in this catalog.
If there is only one electrical feed to the receptacle,
then the duplex DFDU must be used.
If the hot and dimmed hot feeds to the split
duplex HFDU are supplied from different circuits
or split-wired, with separate switch-legs, a means
to simultaneously disconnect these circuits must
be provided at the panel board where they
originate (NEC 210.7(C) 2002 Edition). A 2-pole
circuit breaker or two single-pole circuit breakers
with an approved handle tie can be used to
accomplish this simultaneous disconnect. Feed-
through dimming panels, which are those without
breakers, are recommended when using the HFDU.
For more information on dimming lamps, consult
Lutron Application Note #109, Guide to Dimming
Portable Lamps via Receptacles, at
lutron.com/applicationnotes.
Replacement dimming plugs
120/125 V RP-FDU-10-XX
2
UL/CSA/NOM regulatory approvals
Replacement plugs for dimming
This plug required for use with
Lutron receptacles for dimming
use—plug will work in standard
receptacle
Easily replaces the existing plugs
on lamps
74
75
lutron.com/specificationguide | 1.800.523.9466 | | 1.800.523.9466 | lutron.com/specificationguide
ARCHITECTURAL
WALLPLATE
OPENING
ARCHITECTURAL
WALLPLATE
OPENING
Volume 1 P/N 367-1746 REV G Volume 1 P/N 367-1746 REV G
Architectural wallplates and accessories Architectural wallplates and accessories