Specification Sheet
Table Of Contents
- Introduction
- Table of contents
- Scalable light management solutions
- New energy-saving products
- Four steps to selecting your control: Step 1
- Four steps to selecting your control: Step 2
- Four steps to selecting your control: Step 3
- Four steps to selecting your control: Step 4
- Dimmer families
- Vierti
- Vareo
- Nova T
- Nova
- Centurion
- Maestro
- Maestro IR
- Maestro Wireless
- Spacer System
- Diva
- Lyneo Lx
- MeadowLark
- Skylark
- Abella
- Ceana
- Ariadni
- Glyder
- Rotary
- Credenza and Attaché
- Maestro wallbox occupancy/vacancy sensors
- Radio Powr Savr wireless occupancy/vacancy sensors
- Radio Powr Savr wireless daylight sensors
- Wallplates and accessories: New Architectural
- Wallplates and accessories: Architectural
- Wallplates and accessories: Designer/Claro/Satin Colors
- Wallplates and accessories: Traditional/Fassada
- Mounting
- Ganging and derating
- Lighting load interfaces
- Wiring diagrams
- Glossary
- Visual index
- Patents and trademarks
169
www.lutron.com | 1.800.523.9466 |
Appendix | Mounting
Individual devices
Individual dimmers, switches, wall sensors and
accessories typically mount in standard 1-gang
electrical boxes (fig. A).
Standard ganging
Multiple dimmers, switches, wall sensors and
accessories typically mount in standard multi-gang
electrical backboxes (fig. B–D) under standard
multi-gang wallplates. Some devices may require
derating or reduction in maximum capacity. For more
information on standard ganging, see pg. 170.
Custom Architectural ganging
Architectural dimmers, switches and accessories
may be ganged without derating (fig. E), but
wider-than-standard electrical backboxes and
customized wallplates may be required. For more
information on custom Architectural ganging,
see pg. 170.
Light load power interfaces (pg. 178)
Interfaces typically mount to a standard electrical
junction box (fig. F); must be mounted within 7
degrees of vertical. Maximum output: 5.1 in x 6.3 in.
Interfaces project 1.2 in in front of box.
Ceiling mount sensors (pgs. 144 and 146)
Wireless ceiling mount Radio Powr Savr
TM sensors
(fig. G) mount to circular bracket provided with
sensor using adhesive strips or mounting
hardware provided.
A 1-gang box
(W: 2 in x H: 3 in x D: 2.5 in)
C 3-gang box
(W:6 in x H: 3 in x D: 2.5 in)
B 2-gang box
(W: 4 in x H: 3 in x D: 2.5 in)
G Wireless sensor
mounting bracket
(3.2 in diameter footprint,
mounting brackets are
spaced 1.8 in)
D 4-gang box
(W: 8 in x H: 3 in x D: 2.5 in)
E (2) 1-gang boxes
with
3
/4 in spacer
F Junction box
(W: 4 in x H: 4 in x D: 2.5 in)
Mounting requirements for dimmers, switches, sensors and accessories