Installation Manual

Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 4/05 P/N 030-783 Rev. B
ON
OFF
ON
OFF
ON
OFF
SINGLE-POLE:
Insulated wires connected
to two screws of the same
color. Replace with a
SINGLE-POLE dimmer.
See Step 5a.
OR
3-WAY:
Insulated wires connected to three screws. One of
these wires is connected to a screw of a different-
color (not green) or labeled COMMON. MARK or
TAG this wire to identify it when wiring. Replace
with a 3-WAY dimmer. See Step 5b.
Tag
Different-colored screw
(Common). Actual location may
vary.
OR
Ground (Bare
Copper or
Green Wire)
Ground (Bare Copper
or Green Wire)
ON
OFF
ON
OFF
ON
OFF
Important Notes
Please read before installing.
1. CAUTION: Use only with permanently-installed 120 V incandescent or halogen
fixtures. To avoid overheating and possible damage to other equipment, do not
use to control receptacles, fluorescent lighting fixtures, motor-driven appliances,
or transformer-supplied appliances.
2. Install in accordance with all national and local electrical codes.
3. Only one dimmer can be used in a 3-way circuit.
4. When no “grounding means” exist within the wallbox then NEC
® 2002, Article
404-9 allows a dimmer without a grounding connection to be installed as a
replacement, as long as a plastic, noncombustible wallplate is used. For this type
of installation, cap or remove the green ground wire on the dimmer and use an
appropriate wallplate such as Lutron's
Claro
®
series wallplates.
5. For new installations, install a test switch before installing the dimmer.
6. Recommended minimum load is 40 Watts
7. It is normal for the dimmer to feel warm to the touch during operation.
8. Clean dimmer with a
soft damp cloth only
. Do not use any chemical cleaners.
Dimmer No sides 1 side 2 sides
Rating removed removed removed
600 W 600 W max. 500 W max. 400 W max.
1000 W 1000 W max. 800 W max. 650 W max.
Depending on model number, the dimmer may
include a Lutron Claro
® wallplate. If so, please
remove the front piece of the wallplate from the
adapter before installing. This will expose dimmer
mounting holes and prevent wallplate damage while
installing dimmer.
Grasp and pull front piece of
wallplate from the wallplate
adapter.
Limited Warranty
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit
to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE
YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE
RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL
OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE
MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation
of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you.
This product may be covered by Mexican patent 168,884 and one or more of the following U.S. patents: 4,835,343; 4,876,498; 4,954,768; 5,207,317;
5,637,930; 6,005,308; DES 364,141 and corresponding foreign patents. Lutron, Diva and Claro are registered trademarks of Lutron Electronics Co., Inc.
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
© 2005 Lutron Electronics Co., Inc.
?
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron
Technical Support Center
. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days)
+1-800-523-9466
Other countries 8am – 8pm ET
+1-610-282-3800
Fax +1-610-282-6311
http://www.lutron.com
Installation
1
Turning OFF Power.
Turn power OFF at circuit breaker (or remove fuse).
2
Removing Wallplate and Switch.
Remove wallplate and switch mounting screws.
Carefully remove switch from wall (do not remove wires).
Caution: Verify power
is OFF to switch
before proceeding.
3
Identifying the Type of Circuit.
7
Turning ON Power.
Turn power ON at circuit breaker (or replace fuse).
6
Mounting Dimmer to Wallbox.
Form wires carefully into the wallbox, mount and align dimmer.
Install wallplate.
NOTE: Only one dimmer can be used in
a 3-WAY circuit.
Connect the green dimmer ground wire
to the green or bare copper ground wire
in the wallbox. (See Important Note 4.)
Connect the black dimmer wire to the
wire removed from the different-colored
screw on the switch (marked or tagged
wire). Remove tag from wire.
Connect one of the red dimmer wires to
either of the remaining wires removed
from the switch.
Connect the remaining red dimmer wire
to the remaining wire removed from the
switch.
Connect the green dimmer ground wire
to the green or bare copper ground wire
in the wallbox. (See Important Note 4.)
Connect one of the black dimmer wires
to either of the wires removed from the
switch.
Connect the remaining black dimmer
wire to the other wire removed from the
switch.
Note: To use a 3-Way dimmer (one
black and two red wires) in a single-pole
application, cap off one of the red wires
and follow instructions for single-pole
wiring. (If the on/off switch works
backwards, switch the red wires.)
5
Wiring the Dimmer.
For installations involving more than one control in a wallbox, refer to the
section on Multigang Installations before beginning.
Note: Wire location will vary by product. Reference wires by color, not location.
5a - Single-Pole Wiring
120 V
60 Hz
Black Black
Green
Ground
Light
5b - 3-Way Wiring
Green
Ground
Black
Ground
Red
Black
Tag
Green
Dimmer Capacity Chart
Attach standard wallplate. Replace
Claro
wallplate adapter, and snap on wallplate.
OR
Multigang Installations
When installing more than one control in the same wallbox, it may
be necessary to remove all inner side sections prior to wiring (see
below). If pre-installed, remove the
Claro
wallplate and wallplate
adapter from dimmer. Using pliers, bend side section up and
down until they break off. Repeat for each side section to be
removed. Removal of dimmer side sections reduces maximum
load capacity. Refer to chart below for maximum dimmer
capacity.
P/N 030-783 b
English
Do Not Remove
Outside Sections
Each Control Has Inside
Sections Removed
Middle Control Has Two
Side Sections Removed
Incandescent / Halogen 120 V
Dimmer
Rated at 120 V~ 60 Hz
Models:
600 W
DV-600P
DV-603P
DVSC-600P
DVSC-603P
DVW-600P
DVW-603P
1000 W
DV-10P
DV-103P
DVSC-10P
DVSC-103P
Lutron Technical Support Center 1-800-523-9466 24 hrs / 7 days www.lutron.com
120 V~
60 Hz
120 V~
60 Hz
Black
Green
Light
Red
Red
120 V
60 Hz
Ground
Dimmer
3-Way Switch
4
Disconnecting Switch Wires.
One wire in the
backwired hole
and one to the
screw.
One continuous
wire to the
screw.
Screw Terminals:
Turn screws to loosen.
Push-in Terminals:
Insert screwdriver. Pull
wire out.
Looped Wire:
Turn screw to loosen.
Important Note: Your wall switch may have two wires attached to the same screw (see
illustrations below for examples). Tape these two wires together before disconnecting. If
your switch has two wires attached to the same terminal, connect both wires to the
Dimmer terminal in Step 5.

Summary of content (2 pages)