Installation Manual

Step 6 Wiring the control.
Connect the green or
bare ground wire on the
control (if present) to
the green or bare
copper ground wire in
the wallbox.
Connect the red wire on
the control to the wire
leading to the circuit
breaker or fuse box.
Connect the yellow wire
on the control to the
wire leading to the load.
Connect the white wire
on the control to
neutral.
Using a wire connector,
cap off the red/white
wire on the control. This
wire is not used in a
single pole circuit.
Be certain that the 3-
way switch is on the
line side of the control.
Connect the green or
bare ground wire on the
control (if present) to
the green or bare
copper ground wire in
the wallbox.
Connect the red wire on
the control to one of the
wires leading to the
3-way switch.
Connect the red/white
wire on the control to
the other wire leading to
the 3-way switch.
Connect the yellow wire
on the control to the
wire leading to the load
(marked or tagged
wire).
Connect the white wire
on the control to
neutral.
Step 7 Mount and align control. Install Claro
wallplate (purchased separately).
Step 8 Turn power on.
Warranty
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture
within one year after purchase. For warranty service, return unit to place of purchase or mail to
Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
This warranty is in lieu of all other warranties, express or implied, and the implied warranty of
merchantability is limited to one year from purchase. This warranty does not cover the cost of
installation, removal or reinstallation, or damage resulting from misuse, abuse, or damage from
improper wiring or installation. This warranty does not cover incidental or consequential damages.
This warranty gives you specific legal rights, and you may have other rights which vary from state
to state. Some states do not allow the exclusion or limitation of incidental or consequential
damages, or limitation on how long an implied warranty may last, so the above limitations may not
apply to you.
This product may be covered under one or more of the following U.S. patents: 5,038,081;
5,207,317; 5,510,679; DES 364,141 and corresponding foreign patents. U.S. and foreign patents
pending. Lutron, Diva and Claro are registered trademarks of Lutron Electronics Co., Inc.
© 1998 Lutron Electronics Co., Inc.
ON
OFF
ON
OFF
ON
OFF
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 2/98 P/N 030-494 Rev. C
Single Pole/3-Way
Electronic Low-Voltage Controls
DVELV-303P SELV-303P
Rated at 120VAC, 60Hz, 300W maximum.
Purchase Claro
® wallplate separately.
Important Notes
Please read before installing.
1. CAUTION: To avoid overheating and possible damage to other
equipment, do not use to control receptacles, fluorescent lighting
fixtures, motor-operated or transformer-supplied appliances.
2. Use only to control the primary side of electronic transformer-
supplied low-voltage lighting, or in combination with
incandescent lamps.
3. This product requires a neutral wire in the wallbox. If a neutral
wire is not present, contact a licensed electrician for installation.
4. Some fixture manufacturers do not recommend dimming their
solid-state transformers. To determine if a fixture may be
dimmed, consult Lutron or the fixture manufacturer.
5. This control is overload protected. If the rated wattage is
exceeded, power to the circuit will shut off until the control cools.
If this occurs, remove excess load from the circuit.
6. Control may feel warm to the touch during normal operation.
7. In multi-phase applications, use a separate neutral for each
phase containing a dimmed circuit.
8. If a bare copper or green ground connection is not available in
the wallbox, contact a licensed electrician for installation.
9. For new installations, wire a test switch before installing the
control.
10. The wire connectors provided are suitable for copper wire only.
Refer to Step 5 for proper wire strip lengths.
11. Install in accordance with all national and local electrical codes.
Multi-Unit Installations
When combining controls in a wallbox, remove all inner side
sections prior to wiring (see below). Use pliers to bend side
section up and down until it breaks off. Repeat for each side
section to be removed. Reduction of control capacity is also
required. Refer to chart below for maximum control capacity.
Turn screw
to loosen.
Backwired:
Insert screwdriver.
Pull out wire.
ON
OFF
ON
OFF
ON
OFF
Green
or Bare
Ground
Yellow
Red
White
Tag
OR
120V
60Hz
Red
Red/White
Green or
Bare
Yellow
Ground
White
Load
Align control.
3-WAY circuit:
120V
60Hz
Ground
Red
White
Red/White
Yellow
Load
3-Way
Switch
Green
or Bare
Red/
White
White
Red
Yellow
Ground
Tag
Technical Assistance
If you have questions concerning the installation or operation of
this product, call the
Lutron Technical Assistance Hotline.
Please provide exact model number when calling.
(800) 523-9466 (U.S.A., Canada, and the Caribbean)
other areas call, (610) 282-3800 Fax (610) 282-3090
Web: www.lutron.com
No sides 1 side 2 sides
Model Number removed removed removed
DVELV-303P 300W Max. 250W Max. 200W Max.
SELV-303P 300W Max. 250W Max. 200W Max.
SINGLE POLE circuit:
Can I use any dimmer with
electronic low-voltage
lighting?
No, electronic (solid state)
transformers require special
circuitry only available with
an electronic low-voltage
control.
¿Puedo usar cualquier
atenuador con luces de
bajo voltage electrónicas?
No, transformadores
electrónicos (de estado
sólido) requieren circuitos
especiales disponibles
solamente en atenuadores
estilo bajo voltage
electrónico.
Twist wires
and trim.
3/8"
Twist wire
connector
tight.
Be sure no
bare wire is
exposed.
Do Not Remove Outer
Side Sections.
Remove All Inner Side
Sections (shaded) In Any
Multi-Unit Installation.
OR
Ground
(Bare Copper or Green WIre)
Different-Colored Screw
(Common)
Ground
(Bare Copper
or Green WIre)
SINGLE POLE:
Insulated wires
connected to two
same color screws.
Installation
For installations involving more than one control in a wallbox, refer
to Multi-Unit Installations before beginning.
Step 1 Turn power off at circuit breaker or remove fuse.
Step 2 Remove wallplate. Pull switch from wall.
Step 3 Identify type of switch.
Step 4 Disconnect switch wires.
Step 5 Prepare wires. Twist and trim wires to the proper
length indicated below when completing Step 6.
Strip length: 3/8" for 14, 16,
or 18 gauge
Note: Wire connectors
provided are suitable
for
copper wire only.
For
aluminum wire, consult an
electrician. Use to join the
following combinations:
One 14 gauge with one 16
or 18 gauge.
Cu
Al
Tighten screws
until snug.
Green or
Bare
Neutral
Hot
Neutral
Hot
Red/
White
Español en el reverso
Terminal Screws:
Turn screw to loosen.
3-WAY:
Insulated wires connected to three
screws. MARK or TAG insulated wire
connected to different-colored screw or
screw labeled COMMON.

Summary of content (2 pages)