Installation Guide

Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 3/08 P/N 033-041 Rev. I
ON
OFF
ON
OFF
ON
OFF
Align control and
tighten screws.
ON
OFF
ON
OFF
ON
OFF
Start screws.
Single Pole/3-Way
Quiet Fan-Speed Controls
AYFSQ-F: 1.5 A 120 V~ 60 Hz
DLFSQ-F: 1.5 A 120 V~ 60 Hz
DLFSQ-F-HO: 2 A 120 V~ 60 Hz
DVFSQ-F: 1.5 A 120 V~ 60 Hz
DVFSQ-F-HO: 2 A 120 V~ 60 Hz
DVSCFSQ-F: 1.5 A 120 V~ 60 Hz
DVSCFSQ-F-HO: 2 A 120 V~ 60 Hz
LGFSQ-F: 1.5 A 120 V~ 60 Hz
LGFSQ-F-HO: 2 A 120 V~ 60 Hz
LXFSQ-F: 1.5 A 120 V~ 60 Hz
LXFSQ-F-HO: 2 A 120 V~ 60 Hz
TGFSQ-F: 1.5 A 120 V~ 60 Hz
Important Notes
Please read before installing.
1. CAUTION: To avoid overheating and possible damage to other
equipment, do not use to control receptacles, fluorescent lighting
fixtures, or transformer-supplied appliances.
2. Do not use control with a fan and light that operate with the same
switch.
3. When no
grounding means” exist within the wallbox then the NEC®
2008, Article 404.9 allows a control without a grounding connection
to be installed as a replacement, as long as a plastic, noncombustible
wallpate is used. For this type of installation, cap or remove the green
ground wire on the control and use an appropriate wallplate such as
Claro
® or Fassada® series wallplates by Lutron.
4. Use control with a ceiling paddle fan only. Use only one ceiling pad-
dle fan per control.
5. For new installations, wire a test switch before installing the control.
6. Set multi-speed fans to their highest setting before installing controls.
7. Do not wire controls in a circuit with a GFCI breaker/receptacle.
8. Use only one control in a 3-way circuit.
9. Install in accordance with all national and local electrical codes.
10. Clean control with a soft damp cloth only. Do not use any chemical
cleaners.
Multi-Unit Installations
When combining controls in one wallbox, remove all inner side sections
before wiring (see below). Use pliers to bend each side section up and
down until it breaks off. Reduction of control capacity is not required.
Remove Switch Mounting Screws. Pull Switch from Wall.
Verify the Application.
Disconnect Switch Wires.
Ground
(Bare Copper or Green Wire)
Backwired:
Insert screw-
driver. Pull wire
out.
Terminal
Screws:
Turn screws
to loosen.
OR
Mount and Align Control. Install Wallplate.
Turn Power ON.
Single-Pole:
Insulated wires connect-
ed to two screws of the
same color. See step 5a.
3-Way:
Insulated wires connected to three screws.
TAG insulated wire connected to the differ-
ent-colored (not green) screw or screw
labeled COMMON. See step 5b.
Different-colored
screw (Common)
OR
Ground
(Bare Copper
or Green WIre)
Tag
Wire the Control. Single-Pole Circuit:
Connect the green ground wire
on the control to the green or
bare copper ground wire in the
wallbox (see Important Note 3).
Connect the black wire on the
control to either of the wires
removed from the switch.
Connect the red wire on the con-
trol to the remaining wire
removed from the switch.
Using a wire connector, cap off
the red/white wire. This wire is
not used in a single pole circuit.
Wire the Control. 3-Way Circuit:
Connect the green ground wire
on the control to the green or
bare copper ground wire in the
wallbox (see Important Note 3).
Connect the black wire on the
control to the tagged wire
removed from the different-col-
ored (not green) screw on the
switch.
Connect the red wire on the con-
trol to either of the remaining
wires removed from the switch.
Connect the red/white wire on
the control to the remaining wire
removed from the switch.
Or
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase.
For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage
pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY
IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL
OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTAL-
LATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY
CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY,
OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not
allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last,
so the above limitations may not apply to you.
This product may be covered by Mexican patent 168,884 and one or more of the following U.S. patents: 4,939,383; 5,191,971;
5,207,317; 5,262,678; 5,637,930; 5,359,231; DES 342,234; DES 364,141;D558,151, and corresponding foreign patents.
NEC
is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
Lutron, Claro, and Fassada are
registered trademarks of Lutron Electronics Co., Inc. © 2008 Lutron Electronics Co., Inc.
Technical Assistance
For questions concerning the installation or operation of this product, call the
Lutron Technical Support
Center
. Please provide exact model number when calling.
1-800-523-9466 (U.S.A., Canada, and the Caribbean)
Other countries call +1-610-282-3800
Fax +1-610-282-6311 Internet: www.lutron.com
Important Wiring Information
Twist wire connec-
tor tight.
Be sure no bare
wire is exposed.
When making wire connections, follow the recommended strip lengths and combinations
for the supplied wire connectors. Note: Wire connectors provided are suitable for
copper
wire only.
For aluminum wire, consult an electrician.
Small:
Strip insulation 3/8 in (10 mm) for #14 AWG wire
Strip insulation 1/2 in (13 mm) for #16 AWG or
#18 AWG wire.
Use to join one #14 AWG supply wire with one
#16 AWG or #18 AWG control wire.
Large:
Strip insulation 1/2 in (13 mm) for #10 AWG,
#12 AWG, or #14 AWG wire
Strip insulation 5/8 in (16 mm) for #16 AWG or
#18 AWG wire.
Use to join one or two #12V or #14 AWG supply
wires with one #10 AWG, #12 AWG, #14 AWG,
#16 AWG, or #18 AWG control wire.
Small
Large
Green
Ground
Red/
White
Red
Black
Tag
Black
Ground
Red/
White
Red
Green
Installation
For installations involving more than one control in a wallbox, refer to
Multi-Unit Installations before beginning.
1 Turn Power OFF at Circuit Breaker or Remove Fuse.
P/N 033-041
120 V~
60 Hz
120 V~
60 Hz
11
22
33
Lutron Technical Support Center 1.800.523.9466 24 hrs / 7 days www.lutron.com
44
Important Note: Your wall switch may have two wires attached to the same
screw (see illustrations below for examples). Tape these two wires together before
disconnecting. Connect both wires to the dimmer wire in step 5.
One wire in the
backwired hole and
one to the screw.
One continuous wire
to the screw.
77
66
55bb
55aa
Live Black
Red
Red/White
Green
Ground
Fan
Neutral
Live Black
Red
Red/White
Green
Ground
Fan
Neutral
3-Way
Switch
DDoo nnoott
remove outside
sections
Inside sections are removed
from each control
Side sections are removed
from both sides of middle
control
Break
Side Sections
English
Warning: Before proceeding, verify that power to
the switch is OFF. Otherwise, death or
serious injury could result.

Summary of content (2 pages)