Cut Sheet

Operating voltage
120 V or 277 V @ 60 Hz
Lamp types and wattages
T5 HO: 24 W, 39 W, 54 W
T4 4-pin triple-tube CFL: 26 W, 32 W
Control options
3-Wire control
Available case types
A-case
C-case
Experience the benefits of full-range, 100% to 1% fluorescent dimming. Designed to meet the most
demanding lighting requirements, Hi-lume ballasts enable you to provide the ideal visual environment
for any application. The Hi-lume family is extensive, featuring the world’s only 100% to 1% dimming
ballasts for T4 compact fluorescent lamps. Integrating Hi-lume 1% technology into your designs
affords you full control over the lighting in any space.
Key standards
California Energy Commission Listed
UL Listed (evaluated to the
requirements of UL 935)
CSA certified (evaluated to the
requirements of C22.2 No. 74)
MIL Std. 461E compliant (meets the
requirements of CE101, RE101 and RE102)
Meets FCC Part 18 Non-Consumer
requirements for EMI/RFI emissions
Shown above: Hi-lume ballast, A-case
Model numbers are organized by lamp type, refer to pg. 41 for additional information.
Highest performance dimming to 1%
3-Wire controlled
Mounting
Ballast mounts using two screws (or sheet metal
feature and one screw) within a fluorescent fixture
Ballast is grounded via a mounting screw to the fixture
Lutron® and NEMA® recommend sockets
complying with IEC 60400. Sockets must have
a UL mark as well. Use rapid start sockets, not
instant startsockets.
Terminals accept 16-18 AWG (0.75 to 1.5 mm
2
)
solid copper or tinned stranded wire
Wiring
Hi-lume ballasts require 3 wires plus Ground
(Dimmed Hot, Switched Hot and Neutral); one
16-18 AWG solid copper Class 1 wire per terminal
Maximum ballast-to-lamp-socket lead length is
7 ft (2 m) for T5 HO linear lamps, and 3ft (1m)
for T4 compactlamps
Ballast is grounded via case
For control wiring diagrams, see pg. 70, and for
lamp wiring diagrams, see pg. 78.
Features
Continuous, flicker-free dimming from
100% to 1%
Ballasts maintain consistent light output for different
lamp lengths, ensuring fixture-to-fixture uniformity
3-Wire line voltage control for consistent fixture-to-
fixture dimming
Sensors cannot connect directly to Hi-lume ballasts
Line-voltage miswire protection
Slim-profile design
Lamps turn on at any dimmed level without going
to full brightness
100% performance-tested, including burn-in at
the factory
Specifications
Total Harmonic Distortion (THD): less than 10%
Power factor greater than 0.95
Ballast factor equal to 0.95 for T4 lamps
Ballast factor equal to 1.0 for T5 HO lamps
Environment
Sound rating: Class A
Minimum lamp starting temperature 10º C (50º F)
Maximum ballast case temperature 75º C (167º F)
For system compatibility information, see pg. 12.
Ballasts and drivers | Ballasts and drivers |
32 | Lutron Lutron | 33
Hi-lume® ballasts Hi-lume ballasts