Cut Sheet

*For case type information see pgs. 20-23.
* *Factory-tuned ballast factors available. To customize, visit www.lutron.com/BallastTool
Actual number may vary with lamp model. Please consult the lamp manufacturer for lamp-specific data.
T5 Linear (continued)
Hi-lume® 3D (1% dimming) universal voltage digital dimming ballasts
•
Dimming to 1%
•
Compatible with Lutron® 3-wire fluorescent controls and EcoSystem® digital controls
•
Energy saving
Lamp
Watts
(Length)
Lamps
per
Ballast Model Number
Case
Type*
Input
Voltage
(VAC)
Input
Current
(A)
Input
Power
(W)
Ballast
Factor
(BF)**
System
Lumens
(lm)
System
Efficacy
(lm/W)
Ballast
Efficacy
Factor
(BEF)
Relative
System
Efficacy
(RSE)
14 W
(21.6 in)
1 H3D T514 C U 1 10 C
277 0.07 19.4 1.00 1,350 70 5.16 0.72
240 0.08 19.2 1.00 1,350 70 5.21 0.73
120 0.16 19.2 1.00 1,350 70 5.21 0.73
2 H3D T514 C U 2 10 C
277 0.13 36.0 1.00 2,700 75 2.78 0.78
240 0.15 36.0 1.00 2,700 75 2.78 0.78
120 0.30 36.0 1.00 2,700 75 2.78 0.78
21 W
(33.4 in)
1 H3D T521 C U 1 10 C
277 0.10 26.6 1.00 2,100 79 3.76 0.79
240 0.11 26.3 1.00 2,100 80 3.81 0.80
120 0.22 26.3 1.00 2,100 80 3.81 0.80
2 H3D T521 C U 2 10 C
277 0.18 48.5 1.00 4,200 87 2.06 0.87
240 0.20 48.6 1.00 4,200 86 2.06 0.86
120 0.41 48.7 1.00 4,200 86 2.05 0.86
28 W
(45.2 in)
1 H3D T528 C U 1 10 C
277 0.12 33.0 1.00 2,900 88 3.63 0.85
240 0.13 31.2 1.00 2,900 93 3.21 0.90
120 0.28 33.6 1.00 2,900 86 2.98 0.83
2 H3D T528 C U 2 10 C
277 0.22 59.8 1.00 5,800 97 1.67 0.94
240 0.26 62.4 1.00 5,800 93 1.60 0.90
120 0.52 62.4 1.00 5,800 93 1.60 0.90
*For case type information see pgs. 20-23.
* *Factory-tuned ballast factors available. To customize, visit www.lutron.com/BallastTool
Actual number may vary with lamp model. Please consult the lamp manufacturer for lamp-specific data.
T5 Linear (continued)
EcoSystem (10% dimming) universal voltage digital dimming ballasts
•
Dimming to 10%
•
Compatible with Lutron 3-wire fluorescent controls and EcoSystem digital controls
•
Integral sensor connections
Lamp
Watts
(Length)
Lamps
per
Ballast Model Number
Case
Type*
Input
Voltage
(VAC)
Input
Current
(A)
Input
Power
(W)
Ballast
Factor
(BF)**
System
Lumens
(lm)
System
Efficacy
(lm/W)
Ballast
Efficacy
Factor
(BEF)
Relative
System
Efficacy
(RSE)
14 W
(21.6 in)
1 EC5 T514 J UNV 1 J
277 0.07 19.0 1.00 1,350 71 5.26 0.74
240 0.08 19.2 1.00 1,350 70 5.21 0.74
120 0.16 19.2 1.00 1,350 70 5.21 0.74
2 EC5 T514 J UNV 2 J
277 0.12 32.8 1.00 2,700 82 3.05 0.85
240 0.14 33.3 1.00 2,700 81 3.00 0.85
120 0.28 33.3 1.00 2,700 81 3.00 0.85
21 W
(33.4 in)
1 EC5 T521 J UNV 1 J
277 0.09 24.9 1.00 2,100 84 4.01 0.84
240 0.12 28.8 1.00 2,100 73 3.47 0.73
120 0.22 26.4 1.00 2,100 80 3.79 0.80
2 EC5 T521 J UNV 2 J
277 0.17 46.0 1.00 4,200 91 2.17 0.91
240 0.20 47.2 1.00 4,200 89 2.12 0.89
120 0.39 47.2 1.00 4,200 89 2.12 0.89
28 W
(45.2 in)
1 EC5 T528 J UNV 1 J
277 0.12 32.6 1.00 2,900 89 3.07 0.86
240 0.14 32.9 1.00 2,900 88 3.04 0.85
120 0.27 32.9 1.00 2,900 88 3.04 0.85
2 EC5 T528 J UNV 2 J
277 0.23 64.5 1.00 5,800 90 1.55 0.87
240 0.27 65.0 1.00 5,800 89 1.54 0.86
120 0.54 65.2 1.00 5,800 89 1.53 0.86
35 W
(57.1 in)
1 EC5 T535 J UNV 1 J
277 0.15 42.0 1.00 3,650 87 2.38 0.83
240 0.18 42.3 1.00 3,650 87 2.38 0.83
120 0.35 42.2 1.00 3,650 87 2.38 0.83
Ballasts and drivers | Ballasts and drivers |
48 | Lutron Lutron | 49