Cut Sheet

*For case type information see pgs. 20-23.
* *Factory-tuned ballast factors available. To customize, visit www.lutron.com/BallastTool
Actual number may vary with lamp model. Please consult the lamp manufacturer for lamp-specific data.
T5 Twin-Tube
Hi-lume® 3D (5% dimming) universal voltage digital dimming ballasts
•
Dimming to 5%
•
Compatible with Lutron® 3-wire fluorescent controls and EcoSystem® digital controls
•
Energy saving
Lamp
Watts
(Length)
Lamps
per
Ballast Model Number
Case
Type*
Input
Voltage
(VAC)
Input
Current
(A)
Input
Power
(W)
Ballast
Factor
(BF)**
System
Lumens
(lm)
System
Efficacy
(lm/W)
Ballast
Efficacy
Factor
(BEF)
Relative
System
Efficacy
(RSE)
36 W
(15.5 in)
1 H3D T536 G U 1 10 G
277 0.14 38.4 1.00 2,850 74 2.60 1.04
240 0.17 40.4 1.00 2,850 71 2.48 0.99
120 0.33 39.2 1.00 2,850 73 2.55 1.02
2 H3D T536 G U 2 10 G
277 0.26 71.3 1.00 5,700 80 1.40 1.12
240 0.31 73.7 1.00 5,700 77 1.36 1.09
120 0.61 72.5 1.00 5,700 79 1.38 1.10
40 W
(22.5 in)
1 H3D T540 G U 1 10 G
277 0.16 43.9 1.00 3,100 71 2.28 0.91
240 0.18 42.8 1.00 3,100 72 2.34 0.93
120 0.36 42.8 1.00 3,100 72 2.34 0.93
2 H3D T540 G U 2 10 G
277 0.27 74.0 1.00 6,200 84 1.35 1.08
240 0.32 76.0 1.00 6,200 82 1.32 1.05
120 0.64 76.0 1.00 6,200 82 1.32 1.05
3 H3D T540 G U 3 10 G
277 0.40 109.7 1.00 9,300 85 0.91 1.09
240 0.47 111.7 1.00 9,300 83 0.90 1.07
120 0.95 112.9 1.00 9,300 82 0.89 1.06
50 W
(22.5 in)
1 H3D T550 G U 1 10 G
277 0.20 54.8 1.00 4,000 73 1.82 0.91
240 0.23 54.6 1.00 4,000 73 1.83 0.92
120 0.45 53.5 1.00 4,000 75 1.87 0.93
2 H3D T550 G U 2 10 G
277 0.36 98.7 1.00 8,000 81 1.01 1.01
240 0.42 99.8 1.00 8,000 80 1.00 1.00
120 0.84 99.8 1.00 8,000 80 1.00 1.00
T5 Twin-Tube (continued)
EcoSystem (10% dimming) universal voltage digital dimming ballasts
•
Dimming to 10%
•
Compatible with Lutron 3-wire fluorescent controls and EcoSystem digital controls
•
Integral sensor connections
Lamp
Watts
(Length)
Lamps
per
Ballast Model Number
Case
Type*
Input
Voltage
(VAC)
Input
Current
(A)
Input
Power
(W)
Ballast
Factor
(BF)**
System
Lumens
(lm)
System
Efficacy
(lm/W)
Ballast
Efficacy
Factor
(BEF)
Relative
System
Efficacy
(RSE)
36/39 W
(15.5 in)
1 EC5 T536 J UNV 1 J
277 0.14 38.8 1.00 2,850 73 2.57 0.93
240 0.17 39.6 1.00 2,850 72 2.53 0.91
120 0.33 39.6 1.00 2,850 72 2.53 0.91
2 EC5 T536 J UNV 2 J
277 0.26 72.0 1.00 5,700 79 1.39 1.00
240 0.31 73.2 1.00 5,700 78 1.37 0.98
120 0.61 73.2 1.00 5,700 78 1.37 0.98
40 W
(22.5 in)
1 EC5 T540 J UNV 1 J
277 0.16 44.3 1.00 3,100 70 2.26 0.90
240 0.18 43.2 1.00 3,100 72 2.31 0.93
120 0.36 43.2 1.00 3,100 72 2.31 0.93
2 EC5 T540 J UNV 2 J
277 0.27 74.8 1.00 6,200 83 1.34 1.07
240 0.32 76.8 1.00 6,200 81 1.30 1.04
120 0.64 76.8 1.00 6,200 81 1.30 1.04
3
EC5 T540 G UNV 3L
††
G
277 0.40 111.3 1.00 9,300 84 0.90 1.08
240 0.47 112.4 1.00 9,300 83 0.89 1.07
120 0.95 113.2 1.00 9,300 82 0.88 1.06
50 W
(22.5 in)
1 EC5 T550 J UNV 1 J
277 0.20 55.4 1.00 4,000 72 1.81 0.90
240 0.23 54.0 1.00 4,000 72 1.85 0.93
120 0.45 54.0 1.00 4,000 74 1.85 0.93
2 EC5 T550 J UNV 2 J
277 0.36 99.7 1.00 8,000 80 1.00 1.00
240 0.42 100.8 1.00 8,000 79 0.99 0.99
120 0.84 100.8 1.00 8,000 79 0.99 0.99
55 W
(20.7 in)
1 EC5 T555 J UNV 1 J
277 0.20 55.4 0.90 4,320 78 1.62 0.89
240 0.23 55.2 0.90 4,320 78 1.63 0.90
120 0.46 55.2 0.90 4,320 78 1.63 0.90
2 EC5 T555 J UNV 2 J
277 0.40 110.8 0.90 8,640 78 0.81 0.90
240 0.46 110.4 0.90 8,640 78 0.82 0.90
120 0.92 110.4 0.90 8,640 78 0.82 0.90
*For case type information see pgs. 20-23.
* *Factory-tuned ballast factors available. To customize, visit www.lutron.com/BallastTool
Actual number may vary with lamp model. Please consult the lamp manufacturer for lamp-specific data.
††
Ballast ships with leads.
Ballasts and drivers | Ballasts and drivers |
54 | Lutron Lutron | 55
Fluorescent ballast model numbers Fluorescent ballast model numbers