Cut Sheet

Tu-Wire® control
** Ballast is grounded via case.
Features
1
Power terminals accept only
one 16-18 AWG wire
Control wiring overview
Ballasts that dim T4 compact fluorescent lamps
are intended for factory installation by OEM
fixturemanufacturers
Control wire colors may not match ballast or driver
wire colors
Technical wiring details
All wiring from the dimming control to Tu-Wire
ballasts is line-voltage wiring and may be run
together in the same conduit as other line-
voltage wires
Ballasts and lighting fixtures must be
effectively grounded
Ballast must be installed per national and local
electrical codes
Tu-Wire control, A-case or B-case
Ground**
NEU
HOT
N/C
Ballast
Neutral
Dimmed Hot
1
Ballast
Dimmed Hot
Ground**
WHT
BLK
Tu-Wire control, C-case
1
Appendix |Appendix |
72 | Lutron Lutron | 73
Control wiring diagrams Control wiring diagrams