Cut Sheet
09.07.17
369830g
RadioRA 2 Architectural RF GRAFIK T Local Controls
12www.lutron.com/support
Customer Assistance: 1.844.LUTRON1
(U.S.A. / Canada)
product specifications
Multi-Location Installation with Neutral
1,2
- Control Line Side
RRT-G25LW, RRT-G5NEW, or RRT-G5ANSW with RT-GRDW
Red
Blue
Green
Ground
Companion Device
Green
Ground
Black
Red
Green
Ground
Line/Hot
Neutral
Load
Dimmer / Switch Companion Device
Wiring Diagram 5
120 V~
50/60 Hz
Blue
White
Red
Blue
Wiring Diagrams (continued)
1
Up to 4 companion devices may be connected to each dimmer or switch. Total blue traveler wire length may be up to 150 ft (45 m).
2
Control must be installed on line side of circuit if using neutral wire.
Multi-Location Installation with PHPM - Neutral Required
RRT-G25LW, RRT-G5NEW
1
, or RRT-G5ANSW with RT-GRDW
L/H
N
DH
Red
Blue
Control Neutral
PHPM
Green
Ground
Black
Red
Green
Ground
Line/Hot
Neutral
Load
Dimmer / Switch Companion Device
Wiring Diagram 6
120 V~
50/60 Hz
Blue
White
Zone In
Ground
1
When using -G5NEW, dimming phase must be set to forward phase. See Advanced Programming Mode for details.