Cut Sheet

09.07.17
369830g
RadioRA 2 Architectural RF GRAFIK T Local Controls
4www.lutron.com/support
Customer Assistance: 1.844.LUTRON1
(U.S.A. / Canada)
product specifications
Specifications
Model Numbers Dimmers: RRT-G25LW, RRT-G5NEW
Switch: RRT-G5ANSW
Companion Device:
RT-GRDW
Wallplate:
LWT-G-XXX
1
,
LWT-GG-XXX
1
,
LWT-GGG-XXX
1
,
LWT-GGGG-XXX
1
LWT-GT-XXX
1
,
LWT-GGT-XXX
1
,
LWT-GGGT-XXX
1
,
LWT-TG-XXX
1
LWT-GTT-XXX
1
,
LWT-GGTT-XXX
1
,
LWT-TGG-XXX
1
,
LWT-GTTT-XXX
1
LWT-TTG-XXX
1
,
LWT-TGGG-XXX
1
,
LWT-TTTG-XXX
1
LWT-TTGG-XXX
1
Power 120 V~ 50 / 60 Hz
Typical Power
Consumption
Dimmer / Switch: 0.20 W
Companion Device: 0.10 W
Test conditions: load is off
Regulatory
Approvals
UL, cUL , NOM, FCC, IC, IFTEL
Environment Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90%
humidity, non-condensing. Indoor use only.
Communications Dimmers / Switches communicate with the RadioRA 2 system through Radio
Frequency (RF) and must be located within 30 ft (9 m) of a repeater. Companion
devices are not required to be within a specific range of a repeater.
ESD Protection Tested to withstand electrostatic discharge without damage or memory loss.
Surge Protection Tested to withstand surge voltages without damage or loss of operation, in
accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages
in Low-Voltage AC Power Circuits.
Power Failure Power failure memory: should power be interrupted, the control will return to its
previous state when power is restored.
Mounting Requires a U.S. wallbox. 3 ½ in (89 mm) deep recommended, 2 ¼ in (57 mm)
deep minimum.
Wiring Uses conventional 3-way and 4-way wiring. Total multi-location wire length (blue
wire) between all units must not exceed 150 ft (45 m).
Warranty www.lutron.com/TechnicalDocumentLibrary/warranty.pdf
1
“XXX” in the model number represents color/finish code. See the Colors and Finishes on page 3 for details.