Installation Guide

Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in the U.S.A. 3/06 P/N 033-102 Rev. A
English
Canopy Module
CM-FQ1: 120 V~ 60 Hz
1.0
A fan
Wall Control
MA-FQ4M: 120 V~ 60 Hz
4.0 A (up to 4 CM-FQ1)
Accessory Control
MA-AFQ4: 120 V~ 60 Hz
4.0 A
Important Notes
Please read before installing.
1. Caution: To avoid overheating and possible damage to other equipment, do not use to control
receptacles, lighting fixtures, transformer-supplied appliances, solid state fan motors, or
exhaust fans. For exhaust fans use Lutron fully variable fan speed controls.
2. Install in accordance with all national and local electrical codes.
3. When no “grounding means” exist within the wallbox then the NEC® 2002, Article 404-9 allows
a wall control without a grounding connection to be installed as a replacement, as long as a
plastic
, noncomb
ustib
le wallplate is used. For this type of installation, cap or remove the green
g
round wire on the w
all control and use an appropr
iate wallplate such as Lutron’s Claro
® or
Satin ColorsTM ser
ies w
allplates
.
4. The Maestro® f
an speed control system consists of a
W
all Control, one to f
our Canop
y
Modules
, and up to tw
o Accessor
y Controls
.
All m
ust be installed correctly before attempting
to control the f
ans
.
Do not attempt to mix Lutron controls with those from other man
uf
acturers
,
or mix Lutron controls not labeled f
or use together
.
5. This system is not compatib
le with f
ans ha
ving a control system b
uilt into the motor
.
6. Do not paint
W
all Control, Canop
y Module
, or Accessor
y Control.
7. Maestro Controls are not compatib
le with standard 3
-
w
a
y/4-way switches.
8. Accessor
y Controls (MA
-
AFQ4) cannot be used individually and m
ust be used in conjunction
with a
Maestro W
all Control (MA
-
FQ4M) in a 3
-
way/4-way application.
9. In an
y 3
-
w
a
y/4-way circuit use only one Wall Control (MA-FQ4M) with up to 2 Accessory
Controls (MA
-
AFQ4).
10. Oper
ate betw
een 32
°
F (0
°C) and 104 °F (40 °C) room temperature. For indoor use only.
11. W
all Control and Accessor
y Controls ma
y f
eel w
arm to the touch during normal operation.
12. Recommended w
allbo
x depth is 2.5" (64
mm) minim
um.
13.
Clean contr
ols with a
soft damp c
loth onl
y
. Do not use an
y chemical cleaners
.
14. This system cannot be used to change the direction of the f
an.
T
o change the f
an direction,
stop the f
an, and then change the position of the s
witch located on the body of the f
an.
15. Do not use pull chains to oper
ate f
an(s) after installing this system.
16. Each Canop
y Module m
ust be installed within a f
an canop
y enclosure.
17. This de
vice complies with P
ar
t 15 of the FCC Rules
. Operation is subject to the following two
conditions:
(1) this de
vice ma
y not cause har
mful interference, and (2) this device must accept
an
y interf
erence receiv
ed, including interf
erence that may cause undesired operation.
Quiet Fan Speed Control Multi-Location
System
®
Fan Speed
Control
Warning: For use with one to four ceiling paddle fans only. Do not use with an
exhaust fan.
One to four ceiling fans only No exhaust fans
NO
TE:
This equipment has been tested and found to comply with the limits for a Class B digital
de
vice
, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against har
mful interf
erence in a residential installation. This equipment generates, uses
and can r
adiate r
adio frequency energy and, if not installed and used in accordance with the
instr
uctions
, may cause harmful interference to radio communications. However, there is no
guar
antee that interf
erence will not occur in a particular installation. If this equipment does cause
har
mful interf
erence to radio or television reception, which can be determined by turning the
equipment off and on, the user is encour
aged to tr
y to correct the interference by one or more of
the f
ollo
wing measures:
- Reor
ient or relocate the receiving antenna.
- Increase the separ
ation betw
een the equipment and receiv
er
.
-
Connect the equipment into an outlet on a circuit diff
erent from that to which the receiv
er is
connected.
- Consult the dealer or an e
xper
ienced r
adio/TV technician f
or help
.
P/N 033-102
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For
w
arr
anty ser
vice
, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-
paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF
MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF
INST
ALLA
TION,
REMO
V
AL OR REINST
ALLA
TION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM
IMPR
OPER
WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL
DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE
MANUF
A
CTURE,
SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE
OF THE UNIT.
This w
arr
anty giv
es y
ou specific legal rights, and you may have other rights which vary from state to state. Some states do not allow
the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the
above limitations may not apply to you.
These products may be covered under the following U.S. patents: 4,992,709; D353,798; and corresponding foreign patents. U.S. and
f
oreign patents pending.
Lutron, Claro
, and Maestro are registered tr
ademar
ks and F
ASS and Satin Colors are trademarks of Lutron
Electronics Co
., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
© 2006 Lutron Electronics Co., Inc.
Operation
Tap Button
Tap once when fan is off - Fan
speed increases to preset level.
Tap once when fan is on - Fan
speed slows to off.
Tap twice quickly - Fan speed
increases to full speed.
LEDs
Indicate exact fan speed
LEDs will change with each press
(LEDs not available on Accessory Controls)
Press to increase fan speed
Press to decrease fan speed
FASSTM - Front
Accessible
Service Switch
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to remove all inner
side sections prior to wiring (see below). Using pliers, bend side sections up and down until they
break off. Repeat for each side section to be removed. Note: Product does not require derating
when side sections are removed.
Breaking Side
Sections
?
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7 days):
+1
-800-523-9466
Other countries 8am – 8pm ET:
+1-610-282-3800
Fax +1-610-282-6311
http://www.lutron.com
Inside sections are
remo
ved from each
control
Side sections are
remo
ved from both
sides of middle control
Do not remo
ve
outside
sections.
Reference Wiring Diagram
Canopy
Module
First Fan / Canopy Module
Live
120
V~
60
Hz
Neutr
al
White
Black
Yellow (Fan)
Lutron Technical Support Center
1-800-523-9466 24 hrs / 7 days www.lutron.com
ON
OFF
ON
OFF
ON
OFF
Turn OFF power.
Turn power OFF at circuit breaker (or remove fuse).
Canopy Module Installation
Set fan speed.
Set fan(s) to highest speed using pull chains.
Install fan(s).
Install fan(s) according to manufacturer's instructions and check for proper operation.
3
2
1
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the supplied wire
connectors (see wire connector bag).
Note: All wire connectors provided are suitable for copper wire only. For
alumin
um wire
, consult an electrician.
Wire Connector
s:
Use to join 14
A
WG or 12
A
WG g
round wire to 18 AWG Wall Control
ground wire, and to join 18 AWG Canopy Module wire to 12, 14, 16
or 18 AWG wire.
Twist wire
connector
tight.
Connect Canopy Module(s).
If you have questions about wiring, call the Lutron Technical Support Center at +1-800-523-9466.
Fan
Canopy
Module
Switched
Live
Black
White
Yellow
Neutral
Canopy
Module Wire:
White
Blac
k
Yellow
Connects to:
Neutral wires in the junction
box and to fan
Switched Live wire(s) from
Wall Control and to
additional fan(s)
Fan
5
To junction box
T
o fixture
Wiring the Canop
y Module (CM
-FQ1):
Use wire connectors to join wires as indicated below
and in the wiring diagram, and to
cap any unused
wires
.
Troubleshooting
Symptom
Fan does not turn ON or no LEDs turn ON.
LEDs on Wall Control cycle rapidly and
bottom LED is ON.
LEDs on Wall Control cycle rapidly and
second lowest LED is ON.
Fan vibrates or wobbles.
Fan speeds too slow.
Wall Control LEDs respond as expected but
fan does not respond properly.
P
ossib
le Cause
F
ront Accessib
le Ser
vice Switch (
F
ASS
) on
control is pulled out to the OFF position.
Man
ual s
witch on f
an is off (e
x:
pull chain).
Break
er is OFF or tr
ipped (or fuse b
lo
wn).
F
an direction s
witch is betw
een f
orw
ard and
re
v
erse
.
Wir
ing error
, call
Lutr
on
T
ec
hnical Suppor
t
Center
at +1
-
800
-
523
-9466.
Unit is not activ
ated proper
ly
.
Activ
ate system
as descr
ibed in Step 15.
Wir
ing error
, call
Lutr
on
T
ec
hnical Suppor
t
Center
at +1
-
800
-
523
-
9466.
Comm
unication error
.
Chec
k wir
ing;
if error
contin
ues
, call
Lutr
on
T
ec
hnical Suppor
t
Center
at +1
-
800
-
523
-
9466.
F
an b
lades not proper
ly balanced.
See f
an
man
uf
acturer's instr
uctions
.
Fan pull chain not set to high.
Fan pull chain not set to high.
Wiring error, call
Lutron Technical Support
Center at +1-800-523-9466.
Switched Live
Fan
Neutral
Typical Wire Colors
Black
White
Disconnect fan.
Remove canopy enclosure from ceiling fan mounting bracket.
Lea
ve any green ground wires connected as directed in fan manufacturer's instructions.
Disconnect fan from remaining wiring in the ceiling.
4
T
o junction box
T
o junction box
Flush Mount BracketDown Rod Bracket
Mounting
bracket
Canopy
enclosure
Switched
Live to
additional
fans
Up to 3
Additional
Fans / Canopy
Modules
(up to 4 total)
W
all
Control
Wallbox
Green
Black
Br
ass
Ground
Br
ass
See Step 12 for two- and three-location control wiring.
Note: Up to f
our ceiling fans can be controlled on one circuit.
Follow steps 4–7 for each fan.