Installation Guide

Lutron Technical Support Center 1-800-523-9466 24 hrs / 7 days www.lutron.com
Cable tie
6b - Flush Mount Brac
ket
Do not install Canopy Module in ceiling.
Attach Canopy Module to bracket with a cable tie.
Ensure cable tie does not come in contact with moving motor parts.
Install cable tie through notches on Canopy Module. Pull tight and clip excess.
To junction box
6a - Down Rod Bracket
Do not install Canopy Module in ceiling.
Slide Canopy Module into the ceiling fan mounting bracket.
To junction box
Remove original wallplate and switch.
Remove the wallplate and switch mounting screws.
Carefully remove switches from wall
(do not remo
ve wires)
.
Attach canopy.
Control Installation
7
8
7b - Flush Mount Brac
ket
Check all wire connections.
Tuck the wires into the junction box and/or bracket.
Ensure wires and/or wire connectors do not come in contact with mo
ving motor parts.
Attach the canop
y enclosure to the f
an mounting br
acket, taking care not to pinch any wires.
To junction box
To junction box
7a - Do
wn Rod Brac
ket
Check all wire connections.
Tuck the wires into the junction box and/or canopy enclosure.
Attach the canopy enclosure to the fan mounting bracket, taking care not to pinch any wires.
Danger: Verify power to
each switch is OFF
before proceeding.
Important Note:
Your wall switch may have two wires attached to the same screw (see illustrations below for examples). Tape these
two wires together before disconnecting. When wiring, connect wires to new Controls the same way they were
connected to the switch.
Identify switch wires.
10
One wire in
the push-in
terminal and
one to the
screw.
One
continuous
wire to the
screw.
Disconnect switch wires.
Connect Control(s).
For installations involving more than one control in a wallbox, refer to Multigang Installations before
beginning.
Only one Wall Control (MA-FQ4M) can be used with up to 2 Accessory Controls (MA-AFQ4).
Ground
Green wire
Black
screw
W
all Control
Brass
screws
Important Wiring Information
Push-in
Terminals: Insert wires fully.
NOTE:
Push-in terminals are for use with 14 AWG solid copper wire only. DO NOT
use str
anded or twisted wire.
Scre
w Terminals: Tighten securely.
Screw terminals are for use with 12 or 14 AWG solid copper wire only. DO NOT use
str
anded or twisted wire.
Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control
OR
12
11
Screw Terminals:
T
urn screws to loosen.
Push-in Terminals:
Insert screwdriver
.
Pull wire out.
Looped Wire:
T
urn screw to loosen.
Wiring the Wall Control (MA-FQ4M):
Connect either of the wires removed from the switch
to the
b
lack
scre
w terminal on the Wall Control.
Connect the remaining wire removed from the switch
to one of the brass screw terminals on the Wall
Control.
Tighten the remaining
brass scre
w terminal on the
W
all Control. It is not used in a single-pole circuit.
Use wire connectors to connect the green ground
wire on the Wall Control to the
bare copper or green
ground wire in the wallbox (see Important Note 3),
and to
cap any unused wires.
Mount Control(s) to wallbox.
Form wires carefully into the wallbox, mount and align the Control(s).
Install wallplate(s).
Caution: Do not
overtighten
mounting screws.
13
Align control and
tighten screws.
Start screws.
Insert Canopy Module.
6
15
16
ON
OFF
ON
OFF
ON
OFF
Turn ON power.
Do not tur
n on po
w
er until
W
all Control, Accessory Control(s) and Canopy Module(s) have been
installed and wired.
Turn power ON at circuit breaker (or replace fuse).
Recommended - Disconnect pull chains.
Disconnect pull chain extensions to prevent fan speed from being adjusted at the fan(s).
Activate system.
Pull out the Front Accessible Service Switch (FASS) at the bottom
of the
Wall Control, wait 10 seconds, then push it back in.
The LEDs will cycle f
or up to 30 seconds
.
If installing more than one
W
all Control/Canop
y Module system,
activate one at a time with
FASS pushed in on all other systems.
Accessory Controls do not require activation.
14
Identify the circuit type.
One switch controlling the fan(s).
This switch will be a single-pole. The switch will have
insulated wires connected to tw
o screws of the same color
plus a g
reen ground screw.
Gr
ound
(Bare Copper or
Green Wire)
T
wo switches controlling the fan(s).
Both switches will be 3-way. Each switch will have
insulated wires connected to three screws plus a green
g
round screw. One of these wires is connected to a screw
of a different color (not green) or labeled COMMON.
TAG
this wire on both s
witches to identify when wiring.
Tagged wire
Different colored
screw (Common)
Ground
(Bare Copper or
Green Wire)
Three switches controlling the fan(s).
Two switches will be 3-way and one will be a 4-way. TAG
the two 3-way switches as in the Two-Location diagram
abo
ve. The 4-way switch will have insulated wires
connected to f
our scre
ws plus a g
reen ground screw.
T
A
G
two insulated wires which are connected to same colored
screws.
Tagged wires
Note: Screw
placement may
be different on
y
our s
witc
h.
Same colored
screw (or marked
IN or OUT)
Ground
(Bare Copper or
Green
Wire)
9c - Three-Location control
9b - Two-Location control
9a - Single-Location control
12a - Single-Location control
12b - Two-Location control
Liv
e
120 V~
60
Hz
Neutral
Canopy Module
and F
an Fixture
Green
Ground
Wallbox
W
all Control
Reference Wiring Diagram
One location will be replaced with a Wall Control (MA-FQ4M) and the other with an Accessory Control (MA-AFQ4).
Ground
Tag
Green wire
Wiring the Wall Control and Accessory Control:
Connect the tagged wire removed from the switch to
the
b
lac
k
scre
w ter
minal on the Control.
Connect one of the remaining wires remo
v
ed from the
switch to one of the
brass screw terminals on the
Control.
Connect the remaining wire remo
v
ed from the s
witch
to the remaining
brass screw terminal on the Control.
Use wire connectors to connect the
green ground
wire on the Control to the
bare copper or green
ground wire in the wallbox (see Important Note 3), and
to
cap an
y un
used wires
.
Live
120 V~
60 Hz
Blac
k
Green
Green
Ground
Ground
Wallbox
Wall Control or
Accessor
y Control
W
all Control or
Accessory Control
W
allbo
x
Reference Wiring Diagram
12c - Three-Location control
One location will be replaced with a Wall Control (MA-FQ4M) and the other two with Accessory Controls
(MA
-AFQ4).
Replace the 4
-way switch
Note:
4
-way switch may be replaced with either a Wall
Control or an Accessor
y Control
Connect both of the tagged wires removed from the
4
-way switch to the
b
lack
scre
w terminal on the
Control (one wire to the scre
w and the other to the
push-in terminal).
Connect one of the remaining wires removed from the
switch to one of the
brass screw terminals on the
Control.
Connect the remaining wire removed from the switch
to the remaining
brass screw terminal on the Control.
Use wire connectors to connect the
green g
round
wire on the Control to the
bare copper or green
ground wire in the wallbox (see Important Note 3),
and to
cap an
y unused wires
.
Replace the two 3-way switches
Follow Step 12b - Two-Location control.
Gr
ound
Tagged wires
Green wire
Live
120
V~
60 Hz
Br
ass
Br
ass
Black
Blac
k
Green
Green
Ground
Ground
W
allbo
x
Wall Control or
Accessor
y Control
Wall Control or
Accessor
y Control
Wall Control or
Accessor
y Control
W
allbox
Green
Ground
Wallbox
Reference Wiring Diagram
9
Wall Control and
Accessory Control
Wall Control or
Accessory Control
Br
ass
Br
ass Brass
Blac
k
Br
ass
Br
ass
Brass
Blac
k
Blac
k
Br
ass
Brass
Brass
Black
Brass
Black
screw
Brass
screws
Black
screw
Brass
screws
Notch
Note: Screw
placement may
be different on
your switch.
W
arning:
F
an(s) will return to
full speed when po
wer is
restored.
Clean up any tools or
ladders near the f
an(s) first.
Canopy Module
and F
an Fixture
Up to 4 Canopy
Modules and Fans
Neutr
al
Canop
y Module
and Fan Fixture
Canop
y Module
and Fan Fixture
Up to 4 Canop
y
Modules and F
ans
Neutral
Canop
y Module
and F
an Fixture
Canop
y Module
and F
an Fixture
Up to 4 Canopy
Modules and Fans