Installation Guide

Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in the U.S.A. 11/10 P/N 033-211 Rev. A
English
Canopy Module
CM-L300FQ1: 120 V~ 60 Hz
300 W light / 1 A fan (3.5 A total)
Wall Control
MA-LFQ35M: 120 V~ 60 Hz
3.5 A (one CM-L300FQ1)
Accessory Control
MA-ALFQ35: 120 V~ 60 Hz
3.5 A
Important Notes
Please read before installing.
1. Caution: To avoid overheating and possible damage to other equipment, do not use to control
receptacles, uorescent or neon lighting xtures, transformer-supplied appliances, solid state
fan motors, or exhaust fans. For exhaust fans use Lutron fully variable fan speed controls.
2. Install in accordance with all national and local electrical codes.
3. When no “grounding means” exist within the wallbox then the NEC® 2002, Article 404-9 allows
a wall control without a grounding connection to be installed as a replacement, as long as a
plastic, noncombustible wallplate is used. For this type of installation, cap or remove the green
ground wire on the wall control and use an appropriate wallplate such as Lutron’s Claro®
series wallplates.
4. The Maestro® dual fan/light control system consists of a Wall Control, a Canopy Module, and
up to two Accessory Controls. All must be installed correctly before attempting to control the
fan/light xture. Do not attempt to mix Lutron controls with those from other manufacturers, or
mix Lutron controls not labeled for use together.
5. This system is not compatible with fans having a control system built into the motor.
6. Do not paint Wall Control, Canopy Module, or Accessory Control.
7. Maestro Controls are not compatible with standard 3-way/4-way switches.
8. Accessory Controls (MA-ALFQ35) cannot be used individually and must be used in conjunction
with a Maestro Wall Control (MA-LFQ35M) in a 3-way/4-way application.
9. In any 3-way/4-way circuit use only one Wall Control (MA-LFQ35M)with up to 2 Accessory
Controls (MA-ALFQ35).
10. Do not use where total lamp wattage is less than 40W or greater than 300 W.
11. Operate between 32 °F (0 °C) and 104 °F (40 °C) room temperature. For indoor use only.
12. Wall Control and Accessory Controls may feel warm to the touch during normal operation.
13. Recommended wallbox depth is 2.5 in (64 mm) minimum.
14. Clean controls with a soft damp cloth only. Do not use any chemical cleaners.
15. This system cannot be used to change the direction of the fan. To change the fan direction,
stop the fan, and then change the position of the switch located on the body of the fan.
16. To maximize light bulb life, use bulbs recommended for fan or
rough service”use.
17. Do not use pull chains to operate fan/light after installing this system.
18. Canopy Module must be installed within a fan canopy enclosure.
19. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:(1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Quiet Fan Speed and Incandescent/Halogen
Dimmer Multi-Location System
®
Fan/Light
Warning: For use with one ceiling paddle fan and light only. Do not use with an
exhaust fan or more than one fan.
One ceiling fan only No exhaust fans
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to
which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
P/N 033-211
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For
warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-
paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF
MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF
INSTALLATION, REMOVAL OR REINST ALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM
IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL
DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE
MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT
SHALL NEVER EXCEED THE PURCHASE PRICE
OF THE UNIT.
This warranty gives you specic legal rights, and you may have other rights which vary from state to state. Some states do not allow
the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the
above limitations may not apply to you.
registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
© 2010 Lutron Electronics Co., Inc.
Operation
Light Level Tap Button
Tap once when lights are off -Lights
brighten smoothly to preset intensity.
Tap once when lights are on -Lights
dim smoothly to off.
Tap twice quickly -Lights brighten
rapidly to full intensity.
Press and hold when lights are on -
Activates delayed fade to off mode. As
the tap button is held, the LEDs will
begin to ash. The rst ashing LED
represents a 10 second fade to OFF.
Each additional ashing LED
represents an additional 10 seconds
of delay before lights fade to OFF (up
to 60 seconds of delay).
Fan Speed Tap Button
Tap once when fan is off -Fan
speed increases to preset level.
Tap once when fan is on -Fan
speed slows to off.
Tap twice quickly -Fan speed
increases to full speed.
Light Level LEDs
Indicate approximate light level
LEDs may not change with each
press
Press to increase light level
Press to decrease light level
Fan speed LEDs
Indicate exact fan speed
LEDs will change with each press
Press to increase fan speed
Press to decrease fan speed
(LEDs not available on Accessory Controls)
FASS TM - Front
Accessible
Service Switch
IMPORTANT NOTICE:
To replace bulb, remove power by pulling the FASS
switch out on the Control.
For any procedure other than routine bulb
replacement,power must be disconnected at the
main electrical panel.
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to remove all inner
side sections prior to wiring (see below). Using pliers, bend side sections up and down until they
break off. Repeat for each side section to be removed.Note: Product does not require derating
when side sections are removed.
Breaking Side
Sections
?
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days):
+1.800.523.9466
Other countries 8am8pm ET:
+1.610.282.3800
México
+1.888.235.2910
Fax +1.610.282.1243
http://www.lutron.com
Inside sections are
removed from each
control
Side sections are
removed from both
sides of middle control
Do not remove
outside
sections.
Reference Wiring Diagram
Canopy
Module
Junction box and Canopy
Live
120 V~
60 Hz
Neutral
White
Black
See Step 12 for two- and three-location control wiring.
Ceiling Fan and Light
Red (Light)
Yellow (Fan)
Lutron Technical Support Center
1.800.523.9466 24 hrs / 7 days www.lutron.com
ON
OFF
ON
OFF
ON
OFF
Turn OFF power.
Turn power OFF at circuit breaker (or remove fuse).
Canopy Module Installation
Set fan speed and lights.
Set fan to highest speed and turn lights on using pull chains.
If two switches control the fan and light separately, note which controls the light.
Install fan.
Install fan according to manufacturer's instructions and check for proper operation.
3
2
1
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the supplied wire
connectors (see wire connector bag).Note: All wire connectors provided are suitable for copper wire only.For
aluminum wire, consult an electrician.
Twist wire
connector
tight.
Connect Canopy Module.
If you have questions about wiring, call the Lutron Technical Support Center at +1.800.523.9466.
Fan
Canopy
Module
Switched Live
Black
White
Yellow
Red
Neutral
Light
Canopy
Module Wire:
White
Black
Yellow
Red
Connects to:
Neutral wires in the junction
box and to fan
Switched Live wire from
Wall Control
Fan
Light
5
To junction box
To fixture
Wiring the Canopy Module (CM-L300FQ1):
Use wire connectors to join wires as indicated below
and in the wiring diagram, and to cap any unused
wires.
Troubleshooting
Symptom
Light or fan does not turn ON or no LEDs
turn ON.
Upper LEDs on Wall Control cycle rapidly
and bottom LED is ON.
Upper LEDs on Wall Control cycle rapidly
and second lowest LED is ON.
Fan vibrates or wobbles.
Light dims in large steps and fan is noisy or
does not spin at correct speed.
Light button controls fan and vice-versa.
Fan speeds too slow.
Wall Control LEDs respond as expected but
fan and/or light does not respond properly.
Possible Cause
Front Accessible Service Switch (FASS ) on
control is pulled out to the OFF position.
Manual switch on fan is off (ex: pull chain).
Light bulb(s) burned out.
Breaker is OFF or tripped (or fuse blown).
Fan direction switch is between forward and
reverse.
Wiring error, call Lutron Technical Support
Center at +1.800.523.9466.
Unit is not activated properly. Activate system
as described in Step 15.
Wiring error, call Lutron Technical Support
Center at +1.800.523.9466.
Communication error. Check wiring; if error
continues, call Lutron Technical Support
Center at +1.800.523.9466.
Fan blades not properly balanced. See fan
manufactur
er's instructions.
Fan and light control wires on Canopy Module
are reversed.
Fan and light control wires on Canopy Module
are reversed.
Fan pull chain not set to high.
Fan and/or light pull chains not set to high/on.
Wiring error, call Lutron Technical Support
Center at +1.800.523.9466.
Switched Live
Fan
Light
Neutral
If the fan and light do not have separate wires, thexture may have a control
system built into the motor and cannot be used with this product.
Typical Wire Colors
Black
Black with White stripe or Blue
White
Disconnect fan.
Remove canopy enclosure from ceiling fan mounting bracket.
If separate wires from the junction box power the fan and light, tag the wire connected to the light wire.
In Step 5, connect this wire to the black Canopy Module wire.
Leave any green ground wires connected as directed in fan manufacturer's instructions.
Disconnect fan from remaining wiring in the ceiling.
4
To junction box To junction box
Flush Mount BracketDown Rod Bracket
Mounting
bracket
Canopy
enclosure
Wall
Control
Wallbox
Green
Black
Brass
Ground
Brass
Lutron, Claro, and Maestro are registered trademarks and FASS is a trademark of Lutron Electronics Co., Inc. NEC is a
Wire Connectors:
Use to join 14 or 12 AWG (1.5 or 2.5 mm²) ground wire to
18 AWG (0.75 mm²) Wall Control ground wire, and to join
18 AWG (0.75 mm²) Canopy Module wire to
12 to 18 AWG (2.5 to 0.75 mm²) wire.

Summary of content (2 pages)