Installation Guide

OFF
ON
WARNING: SHOCK HAZARD.
May result in serious injury or death. Turn off
power at circuit breaker or fuse before installing.
1
Turn power OFF at circuit breaker!
6a
Connect the new MASTER dimmer (MACL) and re-wire OTHER EXISTING switch
6b
Connect the new MASTER dimmer (MACL) and a Maestro® COMPANION dimmer (MA-R, MSC-AD)
7
Mount all devices using the provided screws
8
Turn power ON at circuit breaker
9
Program MASTER dimmer for use with existing switch
2
Remove (but do not disconnect) existing devices
3
Mark wire on the COMMON terminal
See Step 8 on reverse for details.
See Step 3 on reverse for details.
5
Remove middle sections (if ganging devices)
4
Disconnect wires
OR
On both existing devices, mark the wire (for example, using electrical tape) that
is connected to the screw that is a different color (typically black) than all the
others. This screw terminal may also be labeled “COMMON” or “COM”.
Does not include the ground screw.
Rear / side view of existing device
Ground wire (bare or green)
Ground wire
(bare or green)
Ground wire
(bare or green)
Blue screw
Black screw
Brass screw
Green wire
Green wire Green wire
Ground wire (bare or green)
Ground screw
Jumper wire
(included in box)
Different color screw
Remaining wire
Brass screwBlue screw
Black screw
Hold
T
&
R
until an indicator light (IL)
blinks on the MACL dimmer.
T R
&
Using
L
, select IL 1 when an existing
switch is being used.
IL4 is the default for a Maestro® Companion
Dimmer.
L
IL1
Single tap
T
to save setting.
T
Marked wire
Marked wire
10
Adjust dimming range for LEDs and CFLs
OPTIONAL FOR INCANDESCENT / HALOGEN
SKIP THIS STEP IF YOU ARE USING A MAESTRO
® COMPANION DIMMER
MACL
MA-R
For lights switched from two locations
Choose one of the two wiring scenarios shown below (6a or 6b):
+
You MUST perform Step 9 (at right) for dimmer to work correctly.
IL
Blue screw
Black screw
Brass screw
Marked wire Marked wire
MACL
COM
One to breaker and
one to light(s)
FOR ILLUSTRATION
PURPOSES ONLY
(DO NOT DISCONNECT)
(For lights switched from three or more locations, please visit www.lutron.com/macl)
Use 12 / 14 AWG Use 14 AWG
OR
1/2 in
(13 mm)
Fully wrap the wires around the screw and tighten (A), or strip insulated
wires to 1/2 in (13 mm) and insert into the push-in terminals (B).
A B
One to breaker and
one to light(s)
FOR ILLUSTRATION
PURPOSES ONLY
(DO NOT DISCONNECT)