Installation Guide

AFTER INSTALLATION: Adjust dimming range for LEDs and CFLs
LED
+
Dimmer 120 V~ 60 Hz
Quick Install Guide
Install with
confidence
Use included diagrams
or visit our website for
step-by-step instructions.
®
WARNING: SHOCK HAZARD. May result in serious injury or death.
Turn off power at circuit breaker or fuse before installing.
1. Do not use with exhaust fans.
2. Do not use with fans having integrated remote controls.
3. Use MACL-LFQ control with only one ceiling paddle fan per
control. Not for use with DC motor fans.
4. CAUTION: Use only with permanently installed ceiling fan
xtures with screw-in compact uorescent, screw-in LED,
halogen, or incandescent lamps. To avoid overheating
and possible damage to other equipment, do not use to
control receptacles, motor-driven appliances, or low-voltage
transformer-supplied appliances.
5. Install in accordance with all national and local electrical codes.
6. When no “grounding means” exists in wallbox, the 2011
National Electrical CodeR (NECR) allows a control to be installed
as a replacement if 1) a nonmetallic, noncombustible faceplate
is used with non-metallic attachment screws or 2) the circuit
is protected by a ground fault circuit interrupter (GFCI). When
installing a control according to these methods, cap or remove
green wire before screwing control into wallbox and use an
appropriate faceplate such as Claro or Satin Colors series
wallplates by Lutron.
7. For indoor use only between 32 °F and 104 °F (0 °C and
40 °C).
8. Clean dimmers with a soft damp cloth only. Do not use any
chemical cleaners.
Important Notes
Please read before installing
Ganging and Derating
Limited Warranty: www.lutron.com/TechnicalDocumentLibrary/369-119_Wallbox_Warranty.pdf ©2013–2021 Lutron Electronics Co., Inc.
Lutron, FASS and LED+ are trademarks or registered trademarks of Lutron Electronics Co., Inc., in the U.S. and other countries.
The YouTube icon is a trademark of Google LLC.
ON
OFF
English
Receive an Extended Warranty: www.lutron.com/CLregistration
Support: 1.844.LUTRON1 (USA / Canada) +1.888.235.2910 (Mexico)
How-to videos
lutron.com/wiringwizard
INSTALL WITH CONFIDENCE
lutron.com/wiringwizard
VIDEO & STEP-BY-STEP INSTRUCTIONSVIDEO & STEP-BY-STEP INSTRUCTIONS
MACL-LFQ
75 W
LED / CFL
1.5 A
Fan
250 W
Incand. / Hal.
LED
DEL
LFCA
CFL
AFC
Remove side sections if
mounting 2 or more devices side
by side. No derating is required
when ganging this product.
Remove
Keep
Connect
Ground (green or bare)
Yellow
Red
Screw
Terminal
Light
Fan
Tags
Line / HotTag
Green
Before Removing the Old Switch:
Place a single tag on the wire that
is connected to the Line/Hot side
of the switch (the side with the tab).
Place two tags on the wire that is
connected to the switch controlling
the fan.
A
Hold and until
an indicator light (IL)
blinks on the dimmer.
Use or to
improve lowest dimming
level.
B
C
Turn lights off and on at lowest
level to confirm operation.
&
IL
OR
Bend back
and forth
Find the right LED
lutron.com/LEDfinder
Double-tap to turn lights
on to full intensity.
Press & hold for delayed
fade-to-off.
Double-tap to turn fan
on to full speed.
FASS
Pull tab out for bulb replacement.
Operation
LEDs Blinking Error Description
Top and Bottom LED (as shown at left) Light’s circuit is short circuited
Top and 2nd from Bottom LED
Temperature is too high, lamp
wattage too high
Top and 3rd from Bottom LED
Light pull chain in off state or all
the lamps are blown out
Error blink codes
For Troubleshooting, please visit www.lutron.com/support
For advanced programming instructions, please see Lutron Application
Note #669 on www.lutron.com/support
OR
14 AWG ONLY
(1.5 mm
2
)
1/2 in
(13 mm)
B
A
5 in-lbs (0,55 N
m)
12 / 14 AWG
(2.5 1.5 mm
2
)
P/N 0301993 REV A