Installation Guide

3/8 in
(10 mm)
English
Important Notes
Please read before installing.
1. Caution: When installing Halogen/Incandescent Dimmers—To reduce the risk of overheating
and possible damage to other equipment, DO NOT use to control receptacles, motor-operated
appliances, fluorescent lighting fixtures, electronic low-voltage or magnetic low-voltage fixtures or
transformer-supplied appliances.
Caution: When installing Magnetic Low-voltage Dimmers—To reduce the risk of overheating
and possible damage to other equipment, DO NOT use to control receptacles, electronic low-
voltage fixtures or motor-operated appliances.
2. Caution: Operating a dimmed magnetic low-voltage circuit with all lamps inoperative or
removed may result in current flow in excess of normal levels. To avoid possible transformer
overheating or failure, Lutron strongly recommends the following:
DO NOT operate without operative lamps in place.
Replace burned out lamps as soon as possible.
To prevent premature failure due to overcurrent, use transformers with thermal protection
or fused primary transformer windings.
3. Install in accordance with all national and local electrical codes.
4. DO NOT use Maestro® dimmers for compact Fluorescent (Energy Saver) lamps.
5. When no “grounding means” exist within the wallbox then the NEC® 2008, Article 404.9
allows a dimmer without a grounding connection to be installed as a replacement, as long
as a plastic, noncombustible wallplate is used. For this type of installation, cap or remove
the green ground wire on the dimmer and use an appropriate wallplate such as Claro® or
Satin Colors® series wallplates by Lutron.
6. Do not paint Dimmers or
Maestro
Companion Dimmers (MA-R, MSC-AD).
7.
Maestro
Dimmers are not compatible with standard 3-way/4-way switches, for use only with
Maestro
Companion Dimmers (MA-R, MSC-AD).
8.
Maestro
Companion Dimmers (MA-R, MSC-AD) can not be used individually and must be
used in conjunction with a
Maestro
Dimmer in a 3-way/4-way application.
9. In any 3-way/4-way circuit use only one Dimmer with up to 9
Maestro
Companion Dimmers
(MA-R, MSC-AD).
10. Do not use where total lamp wattage is less than 40 W / VA or greater than wattage indicated
on unit label.
11. Operate between 32 °F (0 °C) and 104 °F (40 °C).
12. Smart Dimmers may feel warm to the touch during normal operation.
13. Recommended wallbox depth is 2.5 in (64 mm) minimum.
14. Maximum wire length between the Dimmer and the last
Maestro
Companion Dimmer
(MA-R, MSC-AD) is 250 feet (76 m).
15. Clean dimmers with a
soft damp cloth only
. Do not use any chemical cleaners.
16. DO NOT use Halogen/Incandescent or Electronic Low-Voltage dimmers for Magnetic
Low-Voltage lighting.
For Halogen/Incandescent Lighting use
a Halogen/Incandescent Dimmer.
MA-600, MA-600M, MA-600G, MSC-600, MSC-600M, MSC-600MG
120 V 60 Hz 600 W
MA-1000, MSC-1000, MSC-1000M
120 V 60 Hz 1000 W
For Magnetic Low-Voltage Lighting use a Magnetic
Low-Voltage Dimmer
ONLY
.
MALV-600, MSCLV-600, MSCLV-600M 120 V 60 Hz 600 VA / 450 W
MALV-1000, MSCLV-1000, MSCLV-1000M 120 V 60 Hz 1000 VA
/ 800 W
Companion Dimmer
MA-R, MSC-AD 120 V 60 Hz 8.3 A
For Electronic Low-Voltage Lighting use an Electronic
Low-Voltage Dimmer
ONLY
. Purchase Separately.
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to remove all
inner side sections prior to wiring (see below). Using pliers, bend side sections up and down until
they break off. Repeat for each side section to be removed. Removal of Dimmer side sections
reduces maximum load capacity. Refer to chart below for maximum Dimmer capacity.
Breaking Side Sections
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase.
For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299,
postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY
IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL
OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTAL-
LATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY
CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY,
OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not
allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last,
so the above limitations may not apply to you.
This product is covered under one or more of the following U.S. patents: 5,248,919; 5,399,940; 5,637,930; 5,798,581;
6,169,377; 7,190,125; 7,365,282; 7,546,473 and corresponding foreign patents. U.S. and foreign patents pending. Lutron,
Claro, Satin Colors, and Maestro are registered trademarks and FASS is a trademark of Lutron Electronics Co., Inc. NEC is a
registered trademark of National Fire Protection Association, Quincy, Massachusetts.
© 2009 Lutron Electronics Co., Inc.
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center
. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days)
1.800.523.9466
México
+1.888.235.2910
Other countries 8am – 8pm ET
+1.610.282.3800
Fax +1.610.282.6311
http://www.lutron.com
Installation
11
Identifying the circuit type.
33
Removing wallplates and switches.
Remove the wallplate and switch mounting screws.
Carefully remove switch from wall (do not remove wires).
22
One switch controlling a light fixture.
This switch will be a single-pole. The switch will
have insulated wires connected to two screws of
the same color plus a green ground screw.
See step 5a when wiring.
Ground
(Bare Copper or
Green Wire)
Disconnecting switch wires.
44
Two switches controlling a light fixture.
Both switches will be 3-way. Each switch will
have insulated wires connected to three screws
plus a green ground screw. One of these wires is
connected to a screw of a different color (not
green) or labeled COMMON. TAG this wire on
both switches to identify when wiring.
See step 5b when wiring.
Tagged wire
Different colored
screw (Common)
Ground
(Bare Copper or
Green Wire)
Three switches controlling a light fixture.
Two switches will be 3-way and one will be a 4-
way. TAG the two 3-way switches as in the Two-
Location diagram above. The 4-way switch will
have insulated wires connected to four screws
plus a green ground screw. TAG the two same
color insulated wires which are connected to
opposite colored screws.
Tagged wires
Note: Screw
placement may
be different on
your switch.
Same
colored screw
(or marked IN
or OUT)
Ground
(Bare Copper or
Green Wire)
5a - Single-Location control
Wiring.
For installations involving more than one control in a wallbox, refer to Multigang
Installations before beginning.
Use the screw or push-in terminals when making connections on the Dimmer or
Companion Dimmer.
Wire all controls before mounting.
55
Turning OFF power.
Turn power OFF at circuit breaker (or remove fuse).
5b - Two-Location control
5c - Three-Location control or more
Turning ON power.
Turn power ON at circuit breaker (or replace fuse).
77
Operation
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in the U.S.A. 9/09 P/N 030-1122 Rev. A
030-1122
Easy-to-follow
Instructions
Instrucciones Fáciles
de Seguir
Dimmer Rating
Halogen/Incandescent
600 W
1000 W
Magnetic Low-Voltage
600 VA/450 W*
1000 VA/800 W*
No Sides
Removed
600 W
1000 W
600 VA/450 W*
1000 VA/800 W*
1 Side
Removed
500 W
800 W
500 VA/400 W*
800 VA/650 W*
2 Sides
Removed
400 W
650 W
400 VA/300 W*
650 VA/500 W*
Derating Chart
Each control has inside
section removed.
Middle control has two
side sections removed.
Do not remove
outside sections.
Mounting dimmer and companion Dimmer(s)
to wallbox.
Form wires carefully into the wallbox, mount and align Dimmer
(and Companion Dimmers).
Install wallplate(s).
66
Start screws.
Note: Do not overtighten
mounting screws.
Permanent damage
may occur.
Troubleshooting
3c - Three-Location control
3b - Two-Location control
3a - Single-Location control
Maximum Load
Screw
Terminals:
Turn screws to
loosen.
Push-in
Terminals:
Insert screw-
driver. Pull
wire out.
Important Note: Your wall switch may have two wires attached to the same screw (see illustra-
tions below for examples). Tape these two wires together before disconnecting. When wiring,
connect wires to the Dimmer the same way they were connected to the switch.
One wire in the
backwired hole
and one to the
screw.
One continuous
wire to the
screw.
Looped Wire:
Turn screw to
loosen.
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the
supplied wire connector. Note: All wire connectors provided are suitable for
copper wire only.
For aluminum wire, consult an electrician.
Wire Connector:
Use to join one 14 AWG (1.5 mm
2
) or
12 AWG (2.5 mm
2
) ground wire with
one 18 AWG (0.75 mm
2
) dimmer
ground wire.
Twist wire
connector tight.
Push-in Terminals: Insert wires fully.
Note: Push-in terminals are for use with
14 AWG (1.5 mm
2
)
solid copper wire only.
DO NOT use stranded or twisted wire.
Screw Terminals: Tighten securely.
Screw terminals are for use with 12 AWG
(2.5 mm
2
) or 14 AWG (1.5 mm
2
)
solid copper
wire only.
DO NOT use stranded or twisted
wire.
Trim or strip wallbox wires to the length indicated by the strip gauge on
the back of the dimmer
OR
Wiring the Dimmer:
Connect the green ground wire on the Dimmer to
the bare copper or green ground wire in the wall-
box.
Connect either of the wires removed from the
switch to the black screw terminal on the
Dimmer.
Connect the remaining wire removed from the
switch to the brass screw terminal on the
Dimmer.
Tighten the blue screw terminal on the Dimmer. It
is not used in a single-pole circuit.
Ground
Green wire
Black screw
Brass screw
Blue
Live
120 V~
60 Hz
Neutral
Light
Fixture
Brass
Black
Green
Ground
Wallbox
Dimmer
Dimmer
Reference Wiring Diagram
One location will be replaced with a Dimmer and the other with a Companion Dimmer.
Ground
Tag
Green wire
Black screw
Brass screw
Blue screw
Ground
Tag
Green wire
Black screw
Brass screw
Blue screw
Wiring the Dimmer:
Connect the green ground wire on the Dimmer to
the bare copper or green ground wire in the
wallbox. (See important note 5.)
Connect the tagged wire removed from the switch
to the black screw terminal on the Dimmer.
Connect one of the remaining wires removed from
the switch to the brass screw terminal on the
Dimmer.
Connect the remaining wire removed from the
switch (note wire color) to the blue screw terminal
on the Dimmer.
Wiring the Companion Dimmer (MA-R, MSC-AD):
Connect the green ground wire on the Companion
Dimmer to the bare copper or green ground wire
in the wallbox. (See important note 5.)
Connect the tagged wire removed from the switch
to the black screw terminal on the Companion
Dimmer.
Connect the same color wire connected to the blue
screw terminal on the Dimmer (wire color noted
above) to the blue screw terminal on the
Companion Dimmer.
Connect the remaining wire removed from the
switch to the brass screw terminal on the
Companion Dimmer.
Dimmer
Companion
Dimmer
Blue
Live
120 V~
60 Hz
Blue
Neutral
Light
Fixture
Brass
Brass
Black
Black
Green
Green
Ground
Ground
Wallbox
Dimmer or
Companion Dimmer
Dimmer or
Companion Dimmer
Wallbox
Reference Wiring Diagram
One location will be replaced with a Dimmer and the others with Companion Dimmers.
Only one Dimmer can be used with up to 9 Companion Dimmers.
Replace the 4-way switch(es)
Note: 4-way switches may be replaced with either a
Dimmer or a Companion Dimmer.
Connect the green ground wire on the Dimmer or
Companion Dimmer to the bare copper or green
ground wire in the wallbox. (See important note 5.)
Connect both of the tagged wires (noting their
color) removed from the 4-way switch to the blue
screw terminal on the Dimmer or Companion
Dimmer (one wire to the screw and the other to
the push-in terminal).
Connect one of the remaining wires removed from
the switch to the black screw terminal on the
Dimmer or Companion Dimmer.
Connect the remaining wire removed from the
switch to the brass screw terminal on the Dimmer
or Companion Dimmer.
Ground
Tagged wires
Green wire
Black screw
Brass screw
Blue
screw
Dimmer or
Companion
Dimmer
Replace the 3-way switches
Connect the green ground wire on the Dimmer or
Companion Dimmer to the bare copper or green
ground wire in the wallbox. (See important note 5.)
Connect the tagged wire removed from the switch
to the black screw terminal on the Dimmer or
Companion Dimmer.
Connect the same color wire connected to the
blue screw terminal on the Dimmer or Companion
Dimmer that replaced a 4-way switch (wire color
noted above) to the blue screw terminal on the
Dimmer or Companion Dimmer.
Connect the remaining wire removed from the
switch to the brass screw terminal on the Dimmer
or Companion Dimmer.
Ground
Tag
Green wire
Black screw
Brass screw
Blue screw
Dimmer or
Companion
Dimmer
Blue
Live
120 V~
60 Hz
Blue
Neutral
Light
Fixture
Brass
Brass
Black
Black
Green
Green
Ground
Ground
Wallbox
Dimmer or
Companion Dimmer
Dimmer or
Companion Dimmer
Dimmer or
Companion Dimmer
Wallbox
Blue
Brass
Black
Green
Ground
Wallbox
Reference Wiring Diagram
Tap Button Options
Tap once when unit is off -
Lights brighten smoothly to
preset intensity.
Tap once when unit is on -
Lights dim smoothly to off.
Tap twice quickly -
Lights brighten rapidly to
full intensity.
Press and hold when unit
is on - Each time dimmer is
turned off delayed fade to
OFF can be activated. As the
tap button is held, the LEDs
will begin to flash. The first
flashing LED represents a
10 second fade to OFF. Each
additional flashing LED rep-
resents an additional
10 seconds of delay before
lights fade to OFF (up to
60 seconds of delay).
Dimming Rocker
Press to brighten
Press to dim
LEDs
light level indicators
(not available on Companion Dimmers)
FASSTM - Front
Accessible Service
Switch
IMPORTANT NOTICE:
To replace bulb, power may be
conveniently removed by pulling
the
FASS
switch out on both the
Dimmer and any Companion
Dimmers.
For any procedure other than
routine bulb replacement,
power must be disconnected
at the main electrical panel.
To learn about the Advanced Features of
Maestro
Dimmers including locked preset and
adjustable fade times, please visit:
http://www.lutron.com/maestro/advfeatures
or call the
Lutron Technical Support Center.
1.800.523.9466
Symptom
Light does not turn On or no
LEDs turn On.
Light turns On and Dimmer works,
but Companion Dimmer does not
work.
Light does not remain On, LEDs
glow dimly or blink.
Tap switch on Companion Dimmer
does not work at brightest level.
Possible Cause
• Front Accessible Service Switch (
FASS
) on Dimmer or
Companion Dimmer is pulled out to the OFF position.
• Light bulb(s) burned out.
• Breaker is OFF or tripped.
• Wiring error. Call
Lutron Technical Support Center.
Wire connected to the blue screw terminal on Dimmer
is not the same wire connected to the blue screw
terminal on Companion Dimmer.
Blue screw terminal miswired to neutral wire or
touching ground.
• Load is less that 40 W.
Align dimmer and
tighten screws.
Lutron Technical Support Center 1.800.523.9466 24 hrs / 7 days www.lutron.com
* The maximum lamp wattage is determined by the efficiency of the transformer, with 70%–85% as
typical. For actual transformer efficiency, contact either the fixture or transformer manufacturer.
The total VA rating of the transformer(s) shall not exceed the VA rating of the dimmer.
WARNING: Shock Hazard. May result in serious
injury or death. Turn off power at circuit
breaker before installing the unit.

Summary of content (2 pages)