Installation Guide

English
Important Notes
Please read before installing.
1. Caution: To avoid overheating and possible damage to other equipment, do not use to control
receptacles, fluorescent lighting fixtures, motor-operated or transformer-supplied appliances, or
electronic low-voltage lighting fixtures.
2. Caution: Operating a dimmed magnetic low-voltage circuit with all lamps inoperative or removed
may result in current flow in excess of normal levels. To avoid possible transformer overheating or
failure, Lutron strongly recommends the following:
Do not operate without operative lamps in place.
Replace burned out lamps as soon as possible.
To prevent premature failure due to overcurrent, use transformers with thermal protection or fused
primary transformer windings.
3. Install in accordance with all national and local electrical codes.
4. DO NOT use
Maestro®
dimmers for compact fluorescent (Energy Saver) lamps.
5. When no “grounding means” exist within the wallbox then the NEC
® 2005, Article 404-9 allows a
dimmer without a grounding connection to be installed as a replacement, as long as a plastic, non-
combustible wallplate is used. For this type of installation, cap or remove the green ground wire on
the dimmer and use an appropriate wallplate such as Lutron’s
Claro®
series wallplates.
6. Do not paint Dimmers or
Maestro
Accessory Dimmers (MA-R, MSC-AD).
7.
Maestro IR®
Dimmers are not compatible with standard 3-way/4-way switches. Use only with
Maestro
Accessory Dimmers (MA-R, MSC-AD).
8.
Maestro
Accessory Dimmers (MA-R, MSC-AD) can not be used individually and must be used in
conjunction with a
Maestro IR
Dimmer in a 3-way/4-way application.
9. In any 3-way/4-way circuit use only one Dimmer with up to 9
Maestro
Accessory Dimmers (MA-R,
MSC-AD).
10. Do not use where total lamp wattage is less than 60 W/VA or greater than wattage indicated on unit
label.
11. Operate between 0 °C (32 °F) and 40 °C (104 °F).
12. Dimmers may feel warm to the touch during normal operation.
13. Recommended wallbox depth is 2.5" (64 mm) minimum.
14. Maximum wire length between the Dimmer and the last
Maestro
Accessory Dimmer (MA-R,
MSC-AD) is 250 feet (76 m).
15. Clean dimmers with a
soft damp cloth only
. Do not use any chemical cleaners.
16. DO NOT use Incandescent/Halogen or Electronic Low-Voltage dimmers
for Magnetic Low-Voltage lighting.
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to remove all
inner side sections prior to wiring (see below). Using pliers, bend side sections up and down until
they break off. Repeat for each side section to be removed. Removal of Dimmer side sections
reduces maximum load capacity. Refer to the dimmer capacity chart below.
Breaking Side
Sections
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty
service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED
TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR
DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT
COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CON-
NECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE
PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the
exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limita-
tions may not apply to you.
This product may be covered under one or more of the following U.S. patents: 4,835,343; 5,248,919; 5,399,940; 5,637,930; 5,798,581;
5,909,087; 6,169,377; 6,300,727; 6,380,696; D353,798; D518,447 and corresponding foreign patents. U.S. and foreign patents pending.
Lutron, Claro, Maestro, and Maestro IR are registered trademarks and FASS is a trademark of Lutron Electronics Co., Inc. NEC is a registered
trademark of the National Fire Protection Association, Quincy, Massachusetts. © 2006 Lutron Electronics Co., Inc.
?
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center
. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days)
1-800-523-9466
Other countries 8am – 8pm ET
+1-610-282-3800
Fax +1-610-282-3090
http://www.lutron.com
Installation
ON
OFF
ON
OFF
ON
OFF
11
Identifying the Circuit Type.
33
Removing Wallplate and Switch.
Remove the wallplate and switch mounting screws.
Carefully remove switch from wall (do not remove wires).
22
One switch controlling a light fixture.
This switch will be a single-pole. The switch will
have insulated wires connected to two screws of
the same color plus a green ground screw.
Ground
(Bare Copper or
Green Wire)
Disconnecting Switch Wires.
44
Two switches controlling a light fixture.
Both switches will be 3-way. Each switch will
have insulated wires connected to three screws
plus a green ground screw. One of these wires is
connected to a screw of a different color (not
green) or labeled COMMON. TAG this wire on
both switches to identify when wiring.
Tag
Different colored
screw (Common)
Three or more switches controlling a light fix-
ture.
Two switches will be 3-way and any others will
be 4-way. TAG the two 3-way switches as in the
Two-Location diagram above. The 4-way switch
will have insulated wires connected to four
screws plus a green ground screw. TAG the two
same color insulated wires which are connected
to opposite colored screws. Follow this procedure
for each 4-way switch.
Tag
Note: Screw
placement may
be different on
your switch.
Same colored
screw (or
marked IN or
OUT)
Ground
(Bare Copper or
Green Wire)
Caution: Verify power to each switch
is OFF before proceeding.
Turning Off Power.
Turn power OFF at circuit breaker (or remove
fuse).
5c - Two-Location control
5d - Three-Location control or more
ON
OFF
ON
OFF
ON
OFF
Turning On Power.
Turn power ON at circuit breaker (or replace fuse).
77
Operation
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in the U.S.A. 12/06 P/N 030-864 Rev. B
Type of
Dimmer
Incandescent/Halogen
MIR-600/600M
MIR-1000/1000M
Magnetic Low-Voltage
MIRLV-600/600M*
MIRLV-1000/1000M*
No Sides
Removed
600 W
1000 W
600 VA / 450 W*
1000 VA / 800 W*
1 Side
Removed
500 W
800 W
500 VA / 400 W*
800 VA / 650 W*
2 Sides
Removed
400 W
650 W
400 VA / 300 W*
650 VA / 500 W*
Dimmer Capacity Chart
Each control has inside
section removed.
Middle control has two
side sections removed.
Do not remove
outside sections.
Mounting Dimmer (and Accessory Dimmer) to
Wallbox.
Form wires carefully into the wallbox, mount and align Dimmer (and Accessory
Dimmer).
Install wallplate.
66
Start screws.
Caution: Do not
overtighten mounting
screws.
Troubleshooting
3c - Three-Location control or more
3b - Two-Location control
3a - Single-Location control
Maximum Load
Screw Terminals:
Turn screws to loosen.
Push-in Terminals:
Insert screwdriver. Pull wire out.
Important Note: Your wall switch may have two wires attached to the same screw (see illustra-
tions below for examples). Tape these two wires together before disconnecting. When wiring,
connect wires to the Dimmer the same way they were connected to the switch.
One wire in the
backwired hole
and one to the
screw.
One continuous
wire to the
screw.
Looped Wire:
Turn screw to loosen.
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the
supplied wire connector. Note: All wire connectors provided are suitable for
copper wire only.
For aluminum wire, consult an electrician.
Wire Connector:
Use to join 14 AWG or 12 AWG
ground wire to 18 AWG dimmer
ground wire.
Twist wire con-
nector tight.
Push-in Terminals: Insert wires fully.
NOTE: Push-in terminals are for use with
14 AWG
solid copper wire only.
DO NOT use
stranded or twisted wire.
Screw Terminals: Tighten securely.
Screw terminals are for use with 12 or
14 AWG
solid copper wire only.
DO NOT use
stranded or twisted wire.
Trim or strip wallbox wires to the length indicated by the strip gauge on
the back of the dimmer
OR
One location will be replaced with a Dimmer and the other with an Accessory Dimmer.
Ground
Tag
Green wire
Black screw
Brass screw
Blue screw
Ground
Tag
Green wire
Black
screw
Brass screw Blue screw
Wiring the Dimmer:
Connect the green ground wire on the Dimmer to
the bare copper or green ground wire in the wall-
box. (See Important Note 4.)
Connect the tagged wire removed from the switch
in Step 3 to the black screw terminal on the
Dimmer.
Connect one of the remaining wires removed from
the switch to the brass screw terminal on the
Dimmer.
Connect the remaining wire removed from the
switch (note wire color) to the blue screw terminal
on the Dimmer.
Wiring the Accessory Dimmer (MA-R, MSC-AD):
Connect the green ground wire on the Accessory
Dimmer to the bare copper or green ground wire
in the wallbox. (See Important Note 4.)
Connect the tagged wire removed from the switch
in Step 3 to the black screw terminal on the
Accessory Dimmer.
Connect the same color wire connected to the blue
screw terminal on the Dimmer (wire color noted
above) to the blue screw terminal on the Accessory
Dimmer.
Connect the remaining wire removed from the
switch to the brass screw terminal on the
Accessory Dimmer.
Dimmer
Accessory
Dimmer
Blue
Hot/Live
120 V~
60 Hz
Blue
Neutral
Light
Fixture
Brass
Brass
Black
Black
Green
Green
Ground
Ground
Wallbox
Dimmer or
Accessory Dimmer
Dimmer or
Accessory Dimmer
Wallbox
Reference Wiring Diagram
One location will be replaced with a Dimmer and the others with
Accessory Dimmers
. Only one
Dimmer can be used with up to 9
Accessory Dimmers
.
Replace the 4-way switch(es)
Note: 4-way switches may be replaced with either a
Dimmer or a Accessory Dimmers
Connect the green ground wire on the Dimmer or
Accessory Dimmer to the bare copper or green
ground wire in the wallbox. (See Important Note 4.)
Connect both of the tagged wires (noting their
color) removed from the 4-way switch in Step 3 to
the blue screw terminal on the Dimmer or
Accessory Dimmer (one wire to the screw and the
other to the push-in terminal).
Connect one of the remaining wires removed from
the switch to the black screw terminal on the
Dimmer or Accessory Dimmer.
Connect the remaining wire removed from the
switch to the brass screw terminal on the Dimmer
or Accessory Dimmer.
Ground
Tag
Green wire
Black screw
Brass screw
Blue
screw
Dimmer or
Accessory
Dimmer
Replace the 3-way switches
Connect the green ground wire on the Dimmer or
Accessory Dimmer to the bare copper or green
ground wire in the wallbox. (See Important Note 4.)
Connect the tagged wire removed from the switch
in Step 3 to the black screw terminal on the
Dimmer or Accessory Dimmer.
Connect the same color wire connected to the
blue screw terminal on the Dimmer or Accessory
Dimmer that replaced a 4-way switch (wire color
noted above) to the blue screw terminal on the
Dimmer or Accessory Dimmer.
Connect the remaining wire removed from the
switch to the brass screw terminal on the Dimmer
or Accessory Dimmer.
Blue
Hot/Live
120 V~
60 Hz
Blue
Neutral
Light
Fixture
Brass
Brass
Black
Black
Green
Green
Ground
Ground
Wallbox
Dimmer or
Accessory Dimmer
Dimmer or
Accessory Dimmer
Dimmer or
Accessory Dimmer
Wallbox
Blue
Brass
Black
Green
Ground
Wallbox
Reference Wiring Diagram
Tap Button Options
Tap once when unit is off -
Lights brighten smoothly to
preset intensity.
Tap once when unit is on -
Lights dim smoothly to off.
Tap twice quickly - Lights
brighten rapidly to full inten-
sity.
Press and hold when unit
is on - Each time dimmer is
turned off delayed fade to
OFF can be activated. As the
tap button is held, the LEDs
will begin to flash. The first
flashing LED represents a 10
second fade to OFF. Each
additional flashing LED rep-
resents an additional 10
seconds of delay before
lights fade to OFF (up to 60
seconds of delay).
FASSTM
- Front Accessible
Service Switch
IMPORTANT NOTICE:
To replace bulb, power may be
conveniently removed by
pulling the
FASS
switch out on
the Dimmer or any Accessory
Dimmer.
For any procedure other
than routine bulb replace-
ment, power must be dis-
connected at the main elec-
trical panel.
To learn about the Advanced Features of
Maestro
®
Dimmers including locked preset and
adjustable fade times, please visit:
http://www.lutron.com/maestro/advfeatures
or call the
Lutron Technical Support Center
Symptom
Light does not turn ON or no LEDs
turn ON.
Light turns ON and Dimmer works,
but Accessory Dimmer does not
work.
Light does not remain ON, LEDs glow
dimly or blink.
Tap switch on Accessory Dimmer
does not work when light is at bright-
est level.
Light does not respond to infrared
wireless transmitter.
Possible Cause
Front Accessible Service Switch (
FASS
) on Dimmer or Accessory
Dimmer(s) is pulled out to the OFF position.
Light bulb(s) burned out.
Breaker is OFF or tripped.
Wiring error. Call
Lutron Technical Support Center
Wire connected to the blue screw terminal on Dimmer is not the
same wire connected to the blue screw terminal on Accessory
Dimmer(s).
Blue screw terminal miswired to neutral wire or touching ground.
Load is less that 60 W.
Transmitter batteries installed incorrectly.
Transmitter batteries are low.
Transmitter not aimed directly at dimmer.
Transmitter outside operating range.
Dimmer has already received and responded to command.
Align dimmer and
tighten screws.
IR®
For Incandescent/Halogen Lighting, use
an Incandescent/Halogen Dimmers.
Incandescent/Halogen Dimmer with IR Receiver
MIR-600: 600 W 120 V~ 60 Hz (single-pole unit)
MIR-600M: 600 W 120 V~ 60 Hz (multi-location unit)
MIR-1000: 1000 W 120 V~ 60 Hz (single-pole unit)
MIR-1000M: 1000 W 120 V~ 60 Hz (multi-location unit)
For Magnetic Low-Voltage Lighting, use
a Magnetic Low-Voltage Dimmers
ONLY
.
Magnetic Low-Voltage Dimmer with IR Receiver
MIRLV-600: 600 VA / 450 W 120 V~ 60 Hz (single-pole unit)
MIRLV-600M: 600 VA / 450 W 120 V~ 60 Hz (multi-location unit)
MIRLV-1000: 1000 VA / 800 W 120 V~ 60 Hz (single-pole unit)
MIRLV-1000M: 1000 VA / 800 W 120 V~ 60 Hz (multi-location unit)
Accessory Dimmer
MA-R, MSC-AD 8.3 A 120 V~ 60 Hz
Infrared Wireless Transmitter with One-Touch Button
MIR-ITFS 0.15 W 3 V
For Electronic Low-Voltage Lighting, use
an Electronic Low-Voltage Dimmers
ONLY
.
Electronic Low-Voltage Dimmer with IR Receiver
Purchased Separately
Infrared Wireless Transmitter Operation
Multiple Gang Application
If multiple
Maestro IR
Dimmers are installed in the same location they will perform as below:
Pressing the ON FULL button will cause each dimmer to fade to full brightness, regardless of
whether some are on and some are off.
Pressing the OFF button will cause all dimmers to fade off.
Pressing the BRIGHTEN or DIM buttons will change the light level on all units at the same rate
until the button is released or the lights are at min or max level. If any units are off when the
BRIGHTEN button is pressed they will turn on at the min brightness level.
To save your favorite light level, adjust all the
Maestro IR
dimmers to the desired level then
press and hold the ONE-TOUCH button for about 3 seconds until the dimmer LED begins to
flash. Once your favorite light level is set, pressing the ONE-TOUCH button will cause each
dimmer to return to your favorite light level.
Point the transmitter at the
Maestro IR
Dimmer(s), then use the buttons as outlined below.
ON FULL:
Tap once - lights brighten
smoothly to full intensity.
OFF:
Tap once: 3 second fade to off
Press and hold: 10–60 second
delayed fade to off.
This transmitter is compatable with
most learning remote controls.
Please see the learning remote
control manufacturer’s instructions
for programming information.
BRIGHTEN:
Press to brighten lights
DIM:
Press to dim lights.
ONE-TOUCH BUTTON:
Tap once to recall your favorite
light level.
To store your favorite level, press
and hold for about 3 seconds until
the dimmer LED begins to flash.
(“Off” is a valid preset level.)
Wiring.
For installations involving more than one control in a wallbox, refer to Multigang
Installations before beginning.
Use the screw or push-in terminals when making connections on the Dimmer or
Accessory Dimmer.
Wire all controls before mounting.
55
Ground
(Bare Copper or
Green Wire)
Wiring the Dimmer:
MIR-600, MIR-1000, MIRLV-600, MIRLV-1000
Connect the green ground wire on the Dimmer to
the bare copper or green ground wire in the wall-
box. (See Important Note 4.)
Connect either of the wires removed from the
switch to one of the brass screw terminals on the
Dimmer.
Connect the remaining wire removed from the
switch to the other brass screw terminal on the
Dimmer.
Ground
Green wire
Brass screw
Brass screw
5a - Single-Location control - Single-Pole Unit
Wiring the Dimmer:
MIR-600M, MIR-1000M, MIRLV-600M, MIRLV-
1000M
Connect the green ground wire on the Dimmer to
the bare copper or green ground wire in the
wallbox. (See Important Note 4.)
Connect either of the wires removed from the
switch to the black screw terminal on the
Dimmer.
Connect the remaining wire removed from the
switch to the brass screw terminal on the
Dimmer.
Tighten the blue screw terminal on the Dimmer. It
is not used in a single-pole circuit.
Reference Wiring Diagram
5b - Single-Location control - Multi-Location Unit
Blue
Hot/Live
120 V~
60 Hz
Neutral
Light
Fixture
Brass
Black
Green
Ground
Wallbox
Dimmer
Ground
Green wire
Black screw
Brass screw
Dimmer
Reference Wiring Diagram
Hot/Live
120 V~
60 Hz
Neutral
Light
Fixture
Brass
Brass
Green
Ground
Wallbox
Dimmer
Dimmer
Ground
Tag
Green wire
Black
screw
Brass screw Blue screw
Dimmer or
Accessory
Dimmer
Lutron Technical
Support Center
1-800-523-9466
24 hrs / 7 days
www.lutron.com
030-864
*Note: The maximum lamp wattage is determined by the efficiency of the transformer, with 70–85%
as typical. For actual transformer efficiency, contact either the fixture or transformer manufacturer.
The total VA rating of the transformer(s) shall not exceed the VA rating of the dimmer.
Dimming Rocker
Press to brighten
Press to dim
LEDs
Light level indicators
(not available on
Accessory Dimmers
)

Summary of content (2 pages)