Use and Care Guide

English
®
Important Notes
Please read before installing.
1. Caution: To avoid overheating and possible damage to other equipment, do not use to control
receptacles or transformer-supplied appliances.
2. Install in accordance with all national and local electrical codes.
3. The Electronic Switch (MA/MSC-S8AM) requires a neutral wire for operation. If no neu-
tral wire is present, contact a licensed electrician for installation. No neutral wire is nec-
essary for the installation of the Accessory Switch (MA/MSC-AS).
4. When no “grounding means” exist within the wallbox then the NEC
® 2005, Article 404-9 allows
a switch without a grounding connection to be installed as a replacement, as long as a plastic,
noncombustible wallplate is used. For this type of installation, cap or remove the green ground
wire on the switch and use an appropriate wallplate such as Lutron’s Claro
® or Satin ColorsTM
series wallplates.
5. Do not paint front or back of Electronic Switch (MA/MSC-S8AM) or Accessory Switch
(MA/MSC-AS).
6. The
Maestro
®
Electronic Switch (MA/MSC-S8AM) is not compatible with standard 3-way or
4-way switches. Use only with
Maestro
Accessory Switches (MA/MSC-AS).
7. Accessory Switches (MA/MSC-AS) must be used in conjunction with one Electronic Switch
(MA/MSC-S8AM).
8. In any 3-way/4-way circuit use only one Electronic Switch (MA/MSC-S8AM) with up to 9
Accessory Switches (MA/MSC-AS).
9. Do not use where total load is greater than rating indicated in the Derating Chart below.
10. Do not use where total lighting load is less than 5 W.
11. Operate between 32 °F (0 °C) and 104 °F (40 °C).
12. It is normal for the Electronic Switch (MA/MSC-S8AM) to feel warm to the touch during opera-
tion.
13. Recommended minimum wallbox depth is 2.5 in (64 mm).
14. Maximum wire length between the Electronic Switch (MA/MSC-S8AM) and the furthest
Accessory Switch (MA/MSC-AS) is 250 ft (76 m).
15. When controlling a combined fan and light load, the total load may not exceed 3 A.
16. Clean switches with a
soft damp cloth only
. Do not use any chemical cleaners.
Electronic Switch
MA-S8AM, MSC-S8AM: 120 V~ 60 Hz 8 A max.
Accessory Switch
MA-AS, MSC-AS: 120 V~ 60 Hz 8.3 A
Breaking Side
Sections
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase.
For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299,
postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY
IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR
REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLA-
TION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM
FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF
THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not
allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last,
so the above limitations may not apply to you.
This product is covered under the following U.S. patent: 4,835,343; and corresponding foreign patents. U.S. and foreign patents
pending. Lutron, Claro, and Maestro are registered trademarks and FASS and Satin Colors are trademarks of Lutron Electronics
Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
© 2007 Lutron Electronics Co., Inc.
?
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center
. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days)
1-800-523-9466
Other countries 8am – 8pm ET
+1-610-282-3800
Fax +1-610-282-6311
http://www.lutron.com
Installation
ON
OFF
ON
OFF
ON
OFF
11
Identifying the circuit type.
33
Removing wallplate(s) and standard
switch(es).
Remove the wallplate and standard switch mounting screws.
Carefully remove standard switch from wall (do not remove wires).
22
One standard switch controlling a load.
This standard switch will be single-pole. The
standard switch will have insulated wires con-
nected to two screws of the same color plus a
green ground screw.
Ground
(Bare Copper or
Green Wire)
Disconnecting standard switch wires.
44
Two standard switches controlling a load.
Both standard switches will be 3-way. Each stan-
dard switch will have insulated wires connected
to three screws plus a green ground screw. One
of these wires is connected to a screw either of a
different color (not green) or labeled COMMON.
TAG this wire on both standard switches to iden-
tify when wiring.
Tagged wire
Different colored
screw (Common)
Ground
(Bare Copper or
Green Wire)
Three or more standard switches controlling
a load.
Two standard switches will be 3-way and any
others will be 4-way. TAG the two 3-way stan-
dard switches as in the Two-Location diagram
above. The 4-way standard switch will have
insulated wires connected to four screws plus a
green ground screw. TAG the two same color
insulated wires which are connected to opposite
colored screws. Follow this procedure for each
4-way switch.
Tagged wires
Note: Screw
placement may
be different on
your switch.
Same colored
screw (or
marked IN or
OUT)
Ground
(Bare Copper or
Green Wire)
Caution: Verify power to each switch
is OFF before proceeding.
Single-Location control
Wiring.
For installations involving more than one control in a wallbox, refer to Multigang
Installations before beginning.
Use the screw or push-in terminals when making connections on the Electronic
Switch or Accessory Switch.
If push-in terminals are used, tighten screws securely.
Wire all controls before mounting.
55
Turning OFF power.
Turn power OFF at circuit breaker (or remove fuse).
Multi-Location control
ON
OFF
ON
OFF
ON
OFF
Turning ON power.
Turn power ON at circuit breaker (or replace fuse).
77
Operation
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in the U.S.A. 4/07 P/N 030-865 Rev. C
030-865
Each control has
inside section
removed.
Middle control has
two side sections
removed.
Do not remove
outside
sections.
Mounting switch(es) to wallbox.
Form wires carefully into the wallbox, mount and align Electronic Switch (and
Accessory Switches).
Install wallplate(s).
66
Start screws.
Caution: Do not
overtighten mounting
screws.
Troubleshooting
3c - Three-Location control or more
3b - Two-Location control
3a - Single-Location control
Screw
Terminals:
Turn screws to
loosen.
Push-in
Terminals:
Insert screw-
driver. Pull
wire out.
Important Note: Your wall switch may have two wires attached to the same screw (see illustra-
tions below for examples). Tape these two wires together before disconnecting. When wiring,
connect wires to Electronic/Accessory Switch the same way they were connected to the switch
being replaced.
One wire in the
push-in terminal
and one to the
screw.
One continuous
wire to the
screw.
Looped Wire:
Turn screw to
loosen.
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the
supplied wire connector. Note: All wire connectors provided are suitable for
copper wire only.
For aluminum wire, consult an electrician.
Wire Connector:
Use to join one 14 AWG or 12 AWG
ground wire with one 18 AWG switch
ground wire.
Twist wire con-
nector tight.
Push-in Terminals: Insert wires fully.
NOTE: Push-in terminals are for use with
#14 AWG
solid copper wire only.
DO NOT
use stranded or twisted wire.
Screw Terminals: Tighten securely.
Screw terminals are for use with #12 or
#14 AWG
solid copper wire only.
DO NOT
use stranded or twisted wire.
Trim or strip wallbox wires to the length indicated by the strip gauge on
the back of the switch
OR
Wiring the Electronic Switch:
Connect the green ground wire on the Electronic
Switch to the bare copper or green ground wire
in the wallbox. (See Important Note 4.)
Connect the neutral wire in the wallbox to the
silver screw terminal on the Electronic Switch. If a
neutral wire is not available in the wallbox, contact
a licensed electrician for installation.
Connect the live wire (the wire leading to the cir-
cuit breaker or fusebox) removed from the switch
to the black screw terminal on the Electronic
Switch.
Connect the remaining wire removed from the
switch to the brass screw terminal on the
Electronic Switch.
Tighten the blue screw terminal on the Electronic
Switch. It is not used in a single-pole circuit.
Ground
Green wire
Black screw
Brass screw
Silver screw
Reference Wiring Diagram
Tap Button Options
Tap once when unit is OFF
- Controlled load turns ON.
Tap once when unit is ON -
Controlled load turns OFF.
LED - Glows brightly when the
Electronic Switch is ON or
glows softly as a night light
when Electronic Switch is OFF.
(Not available on Accessory
Switch)
FASSTM
- Front Accessible
Service Switch
IMPORTANT NOTICE:
To replace bulb, power may be
conveniently removed by pulling
the
FASS
switch out on both the
Electronic Switch and any
Accessory Switches.
For any procedure other than
routine bulb replacement, power
must be disconnected at the
main electrical panel.
Symptom
Load does not turn ON, but
LED on Electronic Switch is
ON.
Load does not turn ON and
LED on Electronic Switch is
OFF.
Load turns ON and Electronic
Switch works, but Accessory
Switch does not work.
Load does not remain ON,
LED glows dimly or blinks.
Possible Cause
Lamps are burned out.
Electronic Switch is not properly wired.
Neutral wire is not connected.
Load not properly installed.
Fan not turned on at fixture.
Front Accessible Service Switch (
FASS
) on an Accessory
Switch is pulled out to the OFF position.
Electronic Switch is not properly wired, wires connected to
brass and black screw terminals may be reversed.
Front Accessible Service Switch (
FASS
) on Electronic Switch
or any Accessory Switch is pulled out to the OFF position.
Breaker is OFF or tripped.
Wire connected to the blue screw terminal on Electronic
Switch is not the same wire connected to the blue screw
terminal on Accessory Switch.
Blue screw terminal miswired to neutral wire or touching
ground.
Align switch and
tighten screws.
The Electronic Switch (MA/MSC-S8AM) is rated for lighting and fan loads only.
Multigang Installations
When combining controls in the same wallbox, remove all inner side sections prior to wiring (see
diagram). Using pliers, bend side sections up and down until they break off. Repeat for each side
section to be removed. Refer to the Derating Chart below for maximum Electronic Switch capaci-
ty. Please note that the Electronic Switch is not derated for fan loads, but when controlling a
combined fan and light load, the total load may not exceed 3 A.
Please call the
Lutron Technical Support Center
at 1-800-523-9466 for an up-to-date listing.
Derating Chart
**The
Maestro
Electronic Switch is UL® listed for use with all magnetic fluorescent ballasts, and
with the electronic fluorescent ballasts listed below.
Maximum Load
No Sides
Removed
950 W
950 VA / 650 W
8 A
3 A
Type of Load
Incandescent/
120 V Halogen/
Electronic low voltage
Magnetic low-voltage*
Fluorescent**
General Purpose Fan
1 Side
Removed
750 W
750 VA / 550 W
6.25 A
3 A
2 Sides
Removed
600 W
600 VA / 450 W
5 A
3 A
If a neutral wire is not present, contact a
licensed electrician for installation.
If a neutral wire is not present in either
location, contact a licensed electrician for
installation.
Ground
Tag
Green wire
Silver screw
Black screw
Brass screw
Blue screw
Manufacturer Model Number
Advance Transformer Co. REL-2P32-RH-TP, ICF-2S42-M2-LD
Valmont Electric E232PI120G01
Sylvania QT3X32/120IS, QTP2X32T8/UNC ISN-SC,
QTP2X26/34/43CF/UNV BM
G E/Motorola Lighting G2-RN-T8-1LL-120
Magnetek B232I120RH
Sunpark SL15
* Note: The maximum lamp wattage is determined by the efficiency of the transformer, with
70–85% as typical. For actual transformer efficiency, contact either the fixture or transformer
manufacturer. The total VA rating of the transformer(s) shall not exceed the VA rating of the
switch.
If a neutral wire is not present in any
location, contact a licensed electrician for
installation.
For Two-Location Control wiring, follow Sections A & B. One location will be replaced with an
Electronic Switch and the other with an Accessory Switch.
For Three-Location Control (or more) wiring, follow Sections A, B & C. One location will be
replaced with an Electronic Switch and the others with Accessory Switches. Only one
Electronic Switch can be used with up to 9 Accessory Switches.
Section A: Line side
Wiring the Accessory Switch on Line side:
Connect the green ground wire on the Accessory
Switch to the bare copper or green ground wire
in the wallbox (See 4-Important Wiring
Information).
Connect the tagged wire removed from the switch to
the black screw terminal on the Accessory Switch.
Connect one of the remaining wires removed from the
switch to the brass screw terminal on the Accessory
Switch.
Connect the remaining wire removed from the switch
(note wire color) to the blue screw terminal on the
Accessory Switch.
Ground
Tag
Green wire
Silver screw
Black screw
Brass screw
Blue screw
Section B: Load side
Wiring the Electronic Switch on Load side:
Connect the green ground wire on the Electronic
Switch to the bare copper or green ground wire
in the wallbox (See 4-Important Wiring
Information).
Connect the neutral wire in the wallbox to the
silver screw terminal on the Electronic Switch.
Connect the tagged wire removed from the switch to
the brass screw terminal on the Electronic Switch.
Identify the color of the wire that was connected to
the blue screw terminal in Section A. Connect the
same color wire to the blue screw terminal on the
Electronic Switch.
Connect the remaining wire removed from the switch
to the black screw terminal on the Electronic Switch.
Ground
Green wire
Silver screw
Black screw
Brass screw
Blue screw
Section C: 4-Way
Replace the 4-way switch(es):
Note: 4-way switches must be replaced with an
Accessory Switch.
Connect the green ground wire on the Accessory
Switch to the bare copper or green ground wire
in the wallbox (See 4-Important Wiring
Information).
Identify the color of the wires that were connected to
the blue screw terminals in Sections A & B. Connect
both of the same color wires to the blue screw termi-
nal on the Electronic/Accessory Switch (one wire to
the screw and the other to the push-in terminal.
Connect one of the remaining wires removed from the
switch to the black screw terminal on the Accessory
Switch.
Connect the remaining wire removed from the switch
to the brass screw terminal on the Accessory Switch.
Blue
120 V~
60 Hz
NeutralNeutral
Brass
Black
Silver
Green
Ground
Wallbox
Electronic Switch
Live
Light or
Fan
Fixture(s)
Lutron Technical Support Center 1-800-523-9466 24 hrs / 7 days www.lutron.com
If the wires connected to the black and
brass screws are reversed, the unit will
not operate. It may be necessary to swap
the connections to ensure that the brass
screw is connected to the load.
Electronic switch must be installed on the load side of multi-location wiring.
Blue
120 V~
60 Hz
Blue
NeutralNeutral
Brass
Brass
Black Black
Silver
GreenGreen
Ground
Wallbox Wallbox
Live
Light or
Fan
Fixture(s)
A Line side B Load side
Ground
Blue
120 V~
60 Hz
Neutral
Brass
Black
Silver
Green
Ground
Wallbox
Accessory Switch
Live
A Line side
Blue
Neutral
Brass
Black
Green
Wallbox
Electronic Switch
Light or
Fan
Fixture(s)
B Load side
BlueBrass
Black
Green
Wallbox
Accessory Switch
C 4-Way
Ground Ground
Accessory Switch Electronic Switch