Important Notes
Please read before installing.
1. Caution: To avoid overheating and possible damage to other equipment, do not use to control
receptacles or transformer-supplied appliances.
2. Install in accordance with all national and local electrical codes.
3. The Electronic Switch (MA/MSC-S8AM) requires a neutral wire for operation. If no
neutral wire is present, contact a licensed electrician for installation. No neutral wire is
necessary for the installation of the Accessory Switch (MA/MSC-AS).
4. When no “grounding means” exist in wallbox, the 2011 National Electrical CodeR (NECR) allows
a control to be installed as a replacement if 1) a nonmetallic, noncombustible faceplate is used
with nonmetallic attachment screws or 2) the circuit is protected by a ground fault circuit inter-
rupter (GFCI). When installing a control according to these methods, cap or remove green wire
before screwing control into wallbox.
5. Do not paint front or back of Electronic Switch (MA/MSC-S8AM) or Accessory Switch (MA/
MSC-AS).
6. The Maestro® Electronic Switch (MA/MSC-S8AM) is not compatible with standard 3-way or
4-way switches. Use only with MaestroR Accessory Switches (MA/MSC-AS).
7. In any 3-way/4-way circuit use only one Electronic Switch (MA/MSC-S8AM) with up to 9
Accessory Switches (MA/MSC-AS).
8. Do not use where total load is greater than rating indicated in the Derating Chart below.
9. Do not use where total lighting load is less than 5 W.
10. Operate between 32 °F (0 °C) and 104 °F (40 °C).
11. It is normal for the Electronic Switch (MA/MSC-S8AM) to feel warm to the touch during opera-
tion.
12. Recommended minimum wallbox depth is 2.5 in (64 mm).
13. Maximum wire length between the Electronic Switch (MA/MSC-S8AM) and the furthest
Accessory Switch (MA/MSC-AS) is 250 ft (76 m).
14. When controlling a combined fan and light load, the total load may not exceed 3 A.
15. Clean switches with a soft damp cloth only. Do not use any chemical cleaners
16. Electronic Switch (MA/MSC-S8AM) must be installed on the load side of the circuit.
Electronic Switch
MA-S8AM, MSC-S8AM: 120 V 60 Hz (8 A)
Accessory Switch
MA-AS, MSC-AS: 120 V 60 Hz (8.3 A)
Breaking Side
Sections
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase.
For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, post-
age pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY
IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL
OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTAL-
LATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY
CLAIM FOR DAMAGES ARISING OUT OF OR IN CON NEC TION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY,
OR USE OF THE UNIT SHALL NEVER EXCEED THE PUR CHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not
allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last,
so the above limitations may not apply to you.
Lutron, Claro, and Maestro are registered trademarks and FASS is a trademark of Lutron Electronics Co., Inc. NEC is a regis-
tered trademark of the National Fire Protection Association, Quincy, Massachusetts.
© 2011 Lutron Electronics Co., Inc.
?
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days)
+1.800.523.9466
México
+1.888.235.2910
Other countries 8am – 8pm ET
+1.610.282.3800
Fax +1.610.282.6311
http://www.lutron.com
Installation
1
Identifying the circuit type.
3
Removing wallplate(s) and standard
switch(es).
•Removethewallplateandstandardswitchmountingscrews.
•Carefullyremovestandardswitchfromwall(do not remove wires).
2
One standard switch controlling a load.
This standard switch will be single-pole. The
standard switch will have insulated wires con-
nected to two screws of the same color plus a
green ground screw.
Note: If a neutral wire is not present, contact a
licensed electrician for installation.
Ground
(Bare Copper or
Green Wire)
Disconnecting standard switch wires.
4
Two standard switches controlling a load.
Both standard switches will be 3-way. Each stan-
dard switch will have insulated wires connected
to three screws plus a green ground screw. One
of these wires is connected to a screw either of
a different color (not green) or labeled COMMON.
TAG this wire on both standard switches to iden-
tify when wiring.
Note: If a neutral wire is not present in either
location, contact a licensed electrician for instal-
lation.
Tagged wire
Different colored
screw (Common)
Ground
(Bare Copper or
Green Wire)
Three or more standard switches controlling
a load.
Two standard switches will be 3-way and any
others will be 4-way. TAG the two 3-way stan-
dard switches as in the Two-Location diagram
above. The 4-way standard switch will have
insulated wires connected to four screws plus
a green ground screw. TAG the two same color
insulated wires which are connected to opposite
colored screws. Follow this procedure for each
4-way switch.
Note: If a neutral wire is not present in any loca-
tion, contact a licensed electrician for installation.
Tagged wires
Note: Screw
placement may
be different on
your switch.
Same colored
screw (or marked
IN or OUT)
Ground
(Bare Copper or
Green Wire)
Caution: Verify power to each switch
is OFF before proceeding.
5a - Single-Location control
Wiring.
•Forinstallationsinvolvingmorethanonecontrolinawallbox,refertoMultigang
Installations before beginning.
•Use the screw or push-in terminals when making connections on the Electronic
Switch or Accessory Switch.
•If push-in terminals are used, tighten screws securely.
•Wireallcontrolsbeforemounting.
5
Turning OFF power.
• Turn power OFF at circuit break er (or remove fuse).
5b - Multi-Location control
ON
OFF
ON
OFF
ON
OFF
Turning ON power.
•TurnpowerONatcircuitbreaker(orreplacefuse).
7
Operation
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
05/2011 P/N 030-1583 Rev. A
Each control has
inside section
removed.
Middle control has
two side sections
removed.
Do not remove
outside sections.
Mounting switch(es) to wallbox.
•Formwirescarefullyintothewallbox,mountandalignElectronicSwitch(and
Accessory Switches).
•Installwallplate(s).
6
Start screws.
Caution: Do not overtighten
mounting screws.
Troubleshooting
3c - Three-Location control or more
3b - Two-Location control
3a - Single-Location control
Screw
Terminals:
Turn screws to
loosen.
Push-in
Terminals:
Insert screw-
driver. Pull
wire out.
Important Note: Your wall switch may have two wires attached to the same screw (see illustra-
tions below for examples). Tape these two wires together before disconnecting. When wiring,
connect wires to Electronic/Accessory Switch the same way they were connected to the switch
being replaced.
One wire in the
push-in terminal
and one to the
screw.
One continu-
ous wire to the
screw.
Looped Wire:
Turn screw to
loosen.
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the
supplied wire connector. Note: All wire connectors provided are suitable for copper wire only.
For aluminum wire, consult an electrician.
Wire Connector:
Use to join one 12 AWG or 14 AWG
(2.5 or 1.5 mm²) ground wire with
one 18 AWG (0.75 mm²) switch
ground wire.
Twist wire con-
nector tight.
Push-in Terminals: Insert wires fully.
NOTE: Push-in terminals are for use with
14 AWG (1.5 mm²) solid copper wire only.
DO NOT use stranded or twisted wire.
Screw Terminals: Tighten securely.
Screw terminals are for use with 12 or
14 AWG (2.5 or 1.5 mm²) solid copper wire
only. DO NOT use stranded or twisted wire.
Trim or strip wallbox wires to the length indicated by the strip gauge on
the back of the switch
OR
Wiring the Electronic Switch:
•Connectthegreen ground wire on the Electronic
Switch to the bare copper or green ground wire
in the wallbox (See Section 4 - Important Wiring
Information).
•Connecttheneutralwireinthewallboxtothe
silver screw terminal on the Electronic Switch. If a
neutral wire is not available in the wallbox, contact
a licensed electrician for installation.
•Connectthelivewire(thewireleadingtothecircuit
breaker or fusebox) removed from the switch to the
black screw terminal on the Electronic Switch.
•Connecttheremainingwireremovedfrom
the switch to the brass screw terminal on the
Electronic Switch.
•Tightentheblue screw terminal on the Electronic
Switch. It is not used in a single-pole circuit.
Ground
Green wire
Black screw
Brass screw
Silver screw
Reference Wiring Diagram
Blue Blue
NeutralNeutral
Brass Brass
Black Black
Silver
GreenGreen
Ground
Wallbox
Accessory Switch
Wallbox
Tap Button Options
•Tap once when unit is OFF
- Controlled load turns ON.
•Tap once when unit is ON -
Controlled load turns OFF.
LED - Glows brightly when
the Electronic Switch is ON or
glows softly as a night light
when Electronic Switch is OFF.
(Not available on Accessory
Switch)
FASSTM - Front Accessible
Service Switch
IMPORTANT NOTICE:
To replace bulb, power may be
conveniently removed by pulling
the FASST switch out on both
the Electronic Switch and any
Accessory Switches.
For any procedure other than
routine bulb replacement, power
must be disconnected at the
main electrical panel.
Symptom
Load does not turn ON, but
LED on Electronic Switch
is ON.
Load does not turn ON and
LED on Electronic Switch is
OFF.
Load turns ON and Electronic
Switch works, but Accessory
Switch does not work.
Load does not remain ON,
LED glows dimly or blinks.
Possible Cause
•Lampsareburnedout.
•ElectronicSwitchisnotproperlywired.
•Neutralwireisnotconnected.
•Loadnotproperlyinstalled.
•Fannotturnedonatfixture.
•FrontAccessibleServiceSwitch(FASST) on an Accessory
Switch is pulled out to the OFF position.
•ElectronicSwitchisnotproperlywired,wiresconnectedto
brass and black screw terminals may be reversed.
•FrontAccessibleServiceSwitch(FASST) on Electronic Switch
or any Accessory Switch is pulled out to the OFF position.
•BreakerisOFFortripped.
•WireconnectedtothebluescrewterminalonElectronic
Switch is not the same wire connected to the blue screw
terminal on Accessory Switch.
•Bluescrewterminalmiswiredtoneutralwireortouching
ground.
Align switch and
tighten screws.
NOTE: The Electronic Switch (MA/MSC-S8AM) is rated for lighting and fan loads only.
Multigang Installations
When combining controls in the same wallbox, remove all inner side sections prior to wiring (see
diagram). Using pliers, bend side sections up and down until they break off. Repeat for each side
section to be removed. Refer to the Derating Chart below for maximum Electronic Switch capac-
ity. Please note that the Electronic Switch is not derated for fan loads, but when controlling a
combined fan and light load, the total load may not exceed 3 A.
Please call the Lutron Technical Support Center at +1.800.523.9466 for an up-to-date listing.
Derating Chart
** The MaestroR Electronic Switch is UL® listed for use with all magnetic fluorescent ballasts, and
with the electronic fluorescent ballasts listed below.
Maximum Load
No Sides
Removed
950 W
950 VA / 650 W
950 W
8 A
3 A
Type of Load
Incandescent/Halogen
Magnetic low-voltage*
Electronic low-voltage
Fluorescent**
General Purpose Fan
1 Side
Removed
750 W
750 VA / 550 W
750 W
6.25 A
3 A
2 Sides
Removed
600 W
600 VA / 450 W
600 W
5 A
3 A
Ground
Tag
Green wire
Black screw
Brass screw
Blue screw
Live
Manufacturer Model Number
Advance Transformer Co. REL-2P32-RH-TP, ICF-2S42-M2-LD
Valmont Electric E232PI120G01
Sylvania QT3X32/120IS, QTP2X32T8/UNC ISN-SC,
QTP2X26/34/43CF/UNV BM
GE/Motorola Lighting G2-RN-T8-1LL-120
Magnetek B232I120RH
Sunpark SL15
* Note: The maximum lamp wattage is determined by the efficiency of the transformer, with
70–85% as typical. For actual transformer efficiency, contact either the fixture or transformer
manufacturer. The total VA rating of the transformer(s) shall not exceed the VA rating of the
switch.
For Two-Location Control wiring, follow Figures A and B. One location will be replaced with
an Electronic Switch and the other with an Accessory Switch.
Note: Electronic switch must be installed on the load side of multi-location wiring.
For Three-Location Control (or more) wiring, follow Figures A, B and C. One location will
be replaced with an Electronic Switch and the others with Accessory Switches. Only one
Electronic Switch can be used with up to 9 Accessory Switches.
Wiring the Accessory Switch on Line side:
•Connectthegreen ground wire on the Accessory
Switch to the bare copper or green ground wire
in the wallbox (See Section 4 - Important Wiring
Information).
•Connectthetaggedwireremovedfromtheswitchto
the black screw terminal on the Accessory Switch.
•Connectoneoftheremainingwiresremovedfromthe
switch to the brass screw terminal on the Accessory
Switch.
•Connecttheremainingwireremovedfromtheswitch
(note wire color) to the blue screw terminal on the
Accessory Switch.
Ground
Tag
Green wire
Silver screw
Black screw
Brass screw
Blue screw
Wiring the Electronic Switch on Load side:
•Connectthegreen ground wire on the Electronic
Switch to the bare copper or green ground wire
in the wallbox (See Section 4 - Important Wiring
Information).
•Connecttheneutralwireinthewallboxtothesilver
screw terminal on the Electronic Switch.
•Connectthetaggedwireremovedfromtheswitchto
the brass screw terminal on the Electronic Switch.
•Identifythecolorofthewirethatwasconnectedtothe
blue screw terminal in Figure A. Connect the same
color wire to the blue screw terminal on the Electronic
Switch.
•Connecttheremainingwireremovedfromtheswitch
to the black screw terminal on the Electronic Switch.
Ground
Green wire
Black screw
Brass screw
Blue screw
Figure C: 4-Way
Replace the 4-way switch(es):
Note: 4-way switches must be replaced with an
Accessory Switch.
•Connectthegreen ground wire on the Accessory
Switch to the bare copper or green ground wire
in the wallbox (See Section 4 - Important Wiring
Information).
•Identifythewiresthatwereconnectedtotheblue
screw terminals in Figures A & B. Connect both
wires to the blue screw terminal on the Accessory
Switch (one wire to the screw and the other to the
push-in terminal).
•Connectoneoftheremainingwiresremovedfrom
the switch to the black screw terminal on the
Accessory Switch.
•Connecttheremainingwireremovedfrom
the switch to the brass screw terminal on the
Accessory Switch.
Electronic Switch
Light
or Fan
Fixture(s)
A Line side B Load side
Blue
120 V
60 Hz
Neutral
Brass Brass
Black
Silver
Green Green
Ground Ground
Wallbox
Accessory Switch Accessory Switch
Live
A Line side
Blue
Neutral
Brass
Black
Green
Wallbox
Electronic Switch
Light
or Fan
Fixture(s)
B Load side
Blue
Black
Wallbox
C 4-Way
Ground
Ground
Blue
120 V
60 Hz
NeutralNeutral
Brass
Black
Silver
Green
Ground
Wallbox
Electronic Switch
Live
Light
or Fan
Fixture(s)
Lutron Technical Support Center 1.800.523.9466 24 hrs / 7 days www.lutron.com
Note: If the wires connected to the black
and brass screws are reversed, the unit
will not operate. It may be necessary to
swap the connections to ensure that the
brass screw is connected to the load.
ON
OFF
ON
OFF
ON
OFF
WARNING: Shock Hazard. May result
in serious injury or death. Turn off
power at circuit breaker before
installing the unit.
120 V
60 Hz
030-1583
•Easy-to-follow
Instructions
•Instructions
facilesàsuivre
English/Français
Figure A: Accessory Switch on Line side
Figure B: Electronic Switch on Load side