Installation Guide

English
Important Notes
Please read before installing.
1. Caution: To avoid overheating and possible damage to other equipment, do not use to con-
trol receptacles, fluorescent lighting fixtures, motor-operated or transformer-supplied appli-
ances, or electronic low-voltage lighting fixtures.
2. Caution: Operating a dimmed magnetic low-voltage circuit with all lamps inoperative or
removed may result in current flow in excess of normal levels. To avoid possible transformer
overheating or failure, Lutron strongly recommends the following:
Do not operate without operative lamps in place.
Replace burned out lamps as soon as possible.
To prevent premature failure due to overcurrent, use transformers with thermal protection
or fused primary transformer windings.
3. Install in accordance with all national and local electrical codes.
4. DO NOT use
Maestro
®
dimmers for compact Fluorescent (Energy Saver) lamps.
5. When no “grounding means” exist within the wallbox then the NEC
®
2005, Article 404-9
allows a dimmer without a grounding connection to be installed as a replacement, as long
as a plastic, noncombustible wallplate is used. For this type of installation, cap or remove
the green ground wire on the dimmer and use an appropriate wallplate such as Lutron’s
Claro® or Satin ColorsTM series wallplates.
6. Do not paint Dimmers or
Maestro
Accessory Dimmers (MA-R, MSC-AD).
7.
Maestro
Dimmers are not compatible with standard 3-way/4-way switches, for use only
with
Maestro
Accessory Dimmers (MA-R, MSC-AD).
8.
Maestro
Accessory Dimmers (MA-R, MSC-AD) can not be used individually and must be
used in conjunction with a
Maestro
Dimmer in a 3-way/4-way application.
9. In any 3-way/4-way circuit use only one Dimmer with up to 9
Maestro
Accessory Dimmers
(MA-R, MSC-AD).
10. Do not use where total lamp wattage is less than 40 W/VA or greater than wattage indicated
on unit label.
11. Operate between 0 °C (32 °F) and 40 °C (104 °F).
12. Smart Dimmers may feel warm to the touch during normal operation.
13. Recommended wallbox depth is 2.5" (64 mm) minimum.
14. Maximum wire length between the Dimmer and the last
Maestro
Accessory Dimmer (MA-R,
MSC-AD) is 250 feet (76 m).
15. Clean dimmers with a
soft damp cloth only
. Do not use any chemical cleaners.
16. DO NOT use Incandescent/Halogen or Electronic Low-Voltage dimmers
for Magnetic Low-Voltage lighting.
For Incandescent/Halogen Lighting use
an Incandescent/Halogen Dimmer.
MA-600, MSC-600, MSC-600M 600 W 120 V~ 60 Hz
MA-1000, MSC-1000, MSC-1000M 600 W 120 V~ 60 Hz 1000 W
For Magnetic Low-Voltage Lighting use
a Magnetic Low-Voltage Dimmer ONLY.
MALV-600, MSCLV-600, MSCLV-600M 600 VA / 450 W 120 V~ 60 Hz
MALV-1000, MSCLV-1000, MSCLV-1000M 1000 VA / 800 W 120 V~ 60 Hz
Accessory Dimmer
MA-R, MSC-AD 8.3 A 120 V~ 60 Hz
For Electronic Low-Voltage Lighting use
an Electronic Low-Voltage Dimmer ONLY.
Purchase Separately.
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to remove all
inner side sections prior to wiring (see below). Using pliers, bend side sections up and down until
they break off. Repeat for each side section to be removed. Removal of Dimmer side sections
reduces maximum load capacity. Refer to chart below for maximum Dimmer capacity.
Breaking Side
Sections
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase.
For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299,
postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY
IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL
OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTAL-
LATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY
CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY,
OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not
allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last,
so the above limitations may not apply to you.
This product is covered under one or more of the following U.S. patents: 4,835,343; 5,248,919; 5,399,940; 5,637,930;
5,798,581; DES 353,798 and corresponding foreign patents. U.S. and foreign patents pending. Lutron, Claro, and Maestro are
registered trademarks and FASS and Satin Colors are trademarks of Lutron Electronics Co., Inc. NEC is a registered trademark
of the National Fire Protection Association, Quincy, Massachusetts.
© 2006 Lutron Electronics Co., Inc.
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center
. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days)
1-800-523-9466
Other countries 8am – 8pm ET
+1-610-282-3800
Fax +1-610-282-6311
http://www.lutron.com
Installation
11
Identifying the circuit type.
33
Removing wallplates and switches.
Remove the wallplate and switch mounting screws.
Carefully remove switch from wall (do not remove wires).
22
One switch controlling a light fixture.
This switch will be a single-pole. The switch will
have insulated wires connected to two screws of
the same color plus a green ground screw.
Ground
(Bare Copper or
Green Wire)
Disconnecting switch wires.
44
Two switches controlling a light fixture.
Both switches will be 3-way. Each switch will
have insulated wires connected to three screws
plus a green ground screw. One of these wires is
connected to a screw of a different color (not
green) or labeled COMMON. TAG this wire on
both switches to identify when wiring.
Tagged wire
Different colored
screw (Common)
Ground
(Bare Copper or
Green Wire)
Three switches controlling a light fixture.
Two switches will be 3-way and one will be a 4-
way. Tag the two 3-way switches as in the Two-
Location diagram above. The 4-way switch will
have insulated wires connected to four screws
plus a green ground screw. TAG the two same
color insulated wires which are connected to
opposite colored screws.
Tagged wires
Note: Screw
placement may
be different on
your switch.
Same colored
screw (or
marked IN or
OUT)
Ground
(Bare Copper or
Green Wire)
Caution: Verify power to each switch
is OFF before proceeding.
5a - Single-Location control
Wiring.
For installations involving more than one control in a wallbox, refer to Multigang
Installations before beginning.
Use the screw or push-in terminals when making connections on the Dimmer or
Accessory Dimmer.
Wire all controls before mounting.
55
Turning OFF power.
Turn power OFF at circuit breaker (or remove fuse).
5b - Two-Location control
5c - Three-Location control or more
Turning ON power.
Turn power ON at circuit breaker (or replace fuse).
77
Operation
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in the U.S.A. 12/06 P/N 030-861 Rev. B
030-861
• Easy-to-follow
Instructions
Instrucciones
Fáciles de Seguir
Type of
Dimmer
Incandescent/Halogen
600 W
1000 W
Magnetic Low-Voltage
600 VA / 450 W*
1000 VA / 800 W*
No Sides
Removed
600 W
1000 W
600 VA / 450 W*
1000 VA / 800 W*
1 Side
Removed
500 W
800 W
500 VA / 400 W*
800 VA / 650 W*
2 Sides
Removed
400 W
650 W
400 VA / 300 W*
650 VA / 500 W*
Derating Chart
Each control has
inside section
removed.
Middle control has
two side sections
removed.
Do not remove
outside
sections.
Mounting dimmer and accessory
Dimmer(s) to wallbox.
Form wires carefully into the wallbox, mount and align Dimmer (and Accessory
Dimmers).
Install wallplate(s).
66
Start screws.
Caution: Do not
overtighten mounting
screws.
Troubleshooting
3c - Three-Location control
3b - Two-Location control
3a - Single-Location control
Maximum Load
Screw
Terminals:
Turn screws to
loosen.
Push-in
Terminals:
Insert screw-
driver. Pull
wire out.
Important Note: Your wall switch may have two wires attached to the same screw (see illustra-
tions below for examples). Tape these two wires together before disconnecting. When wiring,
connect wires to the Dimmer the same way they were connected to the switch.
One wire in the
backwired hole
and one to the
screw.
One continuous
wire to the
screw.
Looped Wire:
Turn screw to
loosen.
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the
supplied wire connector. Note: All wire connectors provided are suitable for
copper wire only.
For aluminum wire, consult an electrician.
Wire Connector:
Use to join one 14 AWG or 12 AWG
ground wire with one 18 AWG
dimmer ground wire.
Twist wire con-
nector tight.
Push-in Terminals: Insert wires fully.
NOTE: Push-in terminals are for use with
#14 AWG
solid copper wire only.
DO NOT
use stranded or twisted wire.
Screw Terminals: Tighten securely.
Screw terminals are for use with #12 or
#14 AWG
solid copper wire only.
DO NOT
use stranded or twisted wire.
Trim or strip wallbox wires to the length indicated by the strip gauge on
the back of the dimmer
OR
Wiring the Dimmer:
Connect the green ground wire on the Dimmer to
the bare copper or green ground wire in the wall-
box.
Connect either of the wires removed from the
switch to the black screw terminal on the
Dimmer.
Connect the remaining wire removed from the
switch to the brass screw terminal on the
Dimmer.
Tighten the blue screw terminal on the Dimmer. It
is not used in a single-pole circuit.
Ground
Green wire
Black screw
Brass screw
Blue
Hot/Live
120 V~
60 Hz
Neutral
Light
Fixture
Brass
Black
Green
Ground
Wallbox
Dimmer
Dimmer
Reference Wiring Diagram
One location will be replaced with a Dimmer and the other with a Accessory Dimmer.
Ground
Tag
Green wire
Black screw
Brass screw
Blue screw
Ground
Tag
Green wire
Black screw
Brass screw
Blue screw
Wiring the Dimmer:
Connect the green ground wire on the Dimmer to
the bare copper or green ground wire in the wall-
box.
Connect the tagged wire removed from the switch
to the black screw terminal on the Dimmer.
Connect one of the remaining wires removed from
the switch to the brass screw terminal on the
Dimmer.
Connect the remaining wire removed from the
switch (note wire color) to the blue screw terminal
on the Dimmer.
Wiring the Accessory Dimmer (MA-R, MSC-AD):
Connect the green ground wire on the Accessory
Dimmer to the bare copper or green ground wire
in the wallbox.
Connect the tagged wire removed from the switch
to the black screw terminal on the Accessory
Dimmer.
Connect the same color wire connected to the blue
screw terminal on the Dimmer (wire color noted
above) to the blue screw terminal on the Accessory
Dimmer.
Connect the remaining wire removed from the
switch to the brass screw terminal on the
Accessory Dimmer.
Dimmer
Accessory
Dimmer
Blue
Hot/Live
120 V~
60 Hz
Blue
Neutral
Light
Fixture
Brass
Brass
Black
Black
Green
Green
Ground
Ground
Wallbox
Dimmer or
Accessory Dimmer
Dimmer or
Accessory Dimmer
Wallbox
Reference Wiring Diagram
One location will be replaced with a Dimmer and the others with Accessory Dimmers. Only one
Dimmer can be used with up to 9 Accessory Dimmers.
Replace the 4-way switch(es)
Note: 4-way switches may be replaced with either a
Dimmer or an Accessory Dimmers
Connect the green ground wire on the Dimmer or
Accessory Dimmer to the bare copper or green
ground wire in the wallbox.
Connect both of the tagged wires (noting their
color) removed from the 4-way switch to the blue
screw terminal on the Dimmer or Accessory
Dimmer (one wire to the screw and the other to
the push-in terminal).
Connect one of the remaining wires removed from
the switch to the black screw terminal on the
Dimmer or Accessory Dimmer.
Connect the remaining wire removed from the
switch to the brass screw terminal on the Dimmer
or Accessory Dimmer.
Ground
Tagged wires
Green wire
Black screw
Brass screw
Blue
screw
Dimmer or
Accessory
Dimmer
Replace the 3-way switches
Connect the green ground wire on the Dimmer or
Accessory Dimmer to the bare copper or green
ground wire in the wallbox.
Connect the tagged wire removed from the switch
to the black screw terminal on the Dimmer or
Accessory Dimmer.
Connect the same color wire connected to the
blue screw terminal on the Dimmer or Accessory
Dimmer that replaced a 4-way switch (wire color
noted above) to the blue screw terminal on the
Dimmer or Accessory Dimmer.
Connect the remaining wire removed from the
switch to the brass screw terminal on the Dimmer
or Accessory Dimmer.
Ground
Tag
Green wire
Black screw
Brass screw
Blue screw
Dimmer or
Accessory
Dimmer
Blue
Hot/Live
120 V~
60 Hz
Blue
Neutral
Light
Fixture
Brass
Brass
Black
Black
Green
Green
Ground
Ground
Wallbox
Dimmer or Accessory
Dimmer
Dimmer or Accessory
Dimmer
Dimmer or Accessory
Dimmer
Wallbox
Blue
Brass
Black
Green
Ground
Wallbox
Reference Wiring Diagram
Tap Button Options
Tap once when unit is off -
Lights brighten smoothly to
preset intensity.
Tap once when unit is on -
Lights dim smoothly to off.
Tap twice quickly - Lights
brighten rapidly to full inten-
sity.
Press and hold when unit
is on - Each time dimmer is
turned off delayed fade to
OFF can be activated. As the
tap button is held, the LEDs
will begin to flash. The first
flashing LED represents a 10
second fade to OFF. Each
additional flashing LED rep-
resents an additional 10
seconds of delay before
lights fade to OFF (up to 60
seconds of delay).
Dimming Rocker
Press to brighten
Press to dim
LEDs
light level indicators
(not available on Accessory Dimmers)
FASSTM
- Front Accessible
Service Switch
IMPORTANT NOTICE:
To replace bulb, power may be
conveniently removed by pulling
the
FASS
switch out on both the
Dimmer and any Accessory
Dimmers.
For any procedure other than
routine bulb replacement, power
must be disconnected at the
main electrical panel.
To learn about the Advanced Features of
Maestro
Dimmers including locked preset and
adjustable fade times, please visit:
http://www.lutron.com/maestro/advfeatures
or call the
Lutron Technical Support Center.
Symptom
Light does not turn ON or no
LEDs turn ON.
Light turns ON and Dimmer
works, but Accessory Dimmer
does not work.
Light does not remain ON, LEDs
glow dimly or blink.
Tap switch on Accessory Dimmer
does not work at brightest level.
Possible Cause
Front Accessible Service Switch (
FASS
) on Dimmer or
Accessory Dimmer is pulled out to the OFF position.
Light bulb(s) burned out.
Breaker is OFF or tripped.
Wiring error. Call
Lutron Technical Support Center.
Wire connected to the blue screw terminal on Dimmer is
not the same wire connected to the blue screw terminal
on Accessory Dimmer.
Blue screw terminal miswired to neutral wire or touching
ground.
Load is less that 40 W.
Align dimmer and
tighten screws.
Lutron Technical Support Center 1-800-523-9466 24 hrs / 7 days www.lutron.com
*Note: The maximum lamp wattage is determined by the efficiency of the transformer,
with 70–85% as typical. For actual transformer efficiency, contact either the fixture or
transformer manufacturer. The total VA rating of the transformer(s) shall not exceed the
VA rating of the dimmer.

Summary of content (2 pages)