User Manual

Application Note #480
19 Technical Support — 800.523.9466
®
Two-Location Applications Using an Existing Switch
Settings
An existing 3-way mechanical switch may be used as a second-location control to activate lighting load from either location
after a simple rewire. Additional programming is required to work with a mechanical switch and can be found on page 20.
If using Companion Dimmer(s) for a 3-way application, additional programming is not required.
Wiring Prerequisites: 3-Way Wiring (Using 3-Way Mechanical Switch)
Note: Diagrams are for reference only. Refer to instruction sheet for proper wiring procedures.
WARNING: Shock Hazard. May result in serious injury or death. Turn OFF power at circuit breaker before installing
the unit.
Notes:
Rewiring of existing switch is required; consult the instruction sheet for installation procedures.
If switch is not rewired, it may result in abnormal behavior; consult your instruction sheet for wiring procedure.
If the existing mechanical switch was rewired but the Two‑Location Applications Using an Existing Switch setting is
not changed to select the appropriate second location device, the Maestro® Sensor Dimmer may react abnormally. To
resolve, change this setting to the appropriate device.
Dimmer Line Side
Lighting Load
Neutral
Live
Different Color Screw
Black
No connection
Brass
Maestro®
Sensor Dimmer
3-Way Mechanical Switch
Blue
120 V~ 60 Hz
Ground
Ground
Dimmer Load Side
Lighting Load
Neutral
Live
Different Color Screw
Black
No connection
Brass
Maestro®
Sensor Dimmer3-Way Mechanical Switch
Blue
120 V~ 60 Hz
Ground
Ground
Continued on next page…