Specification Sheet

B11
www.lutron.com | 1.800.523.9466 |
Addendum | Custom Architectural Wallplates
Controls must have side sections removed to gang if using VWP wallplates.
1
Recommended 40 W minimum load.
No fins broken 1 fin broken 2 fins broken
Incandescent
1
Dimmers
600 W 600 W 600 W
1000 W 900 W 700 W
1500 W 1250 W 1000 W
2000 W 1800 W 1500 W
Magnetic low-voltage
1
Dimmers
600 VA / 450 W 600 VA / 450 W 500 VA / 400 W
1000 VA / 800 W 900 VA / 750 W 700 VA / 500 W
1500 VA / 1200 W 1250 VA / 1000 W 1000 VA / 800 W
2000 VA / 1600 W 1800 VA / 1500 W 1500 VA / 1200 W
Electronic low-voltage
Dimmers
450 W 400 W 350 W
Fluorescent
Hi-lume
®/Hi-lume® Compact SE/Eco-10®/EcoSystem®
Nova
16 A no derating no derating
8 A no derating no derating
6 A no derating no derating
0-10 VDC control 60 ballasts / 16 A no derating no derating
Tu-Wire
® 5 A 4 A 3.3 A
Fan controls
Fully variable
6 A 5.5 A 5 A
12 A 11 A 10 A
Derating Table 3
Architectural | Nova
®