Installation Manual
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299 U.S.A.
Made and printed in U.S.A. 8/99 P/N 030-408 Rev. C
Multigang Installation
Multiple controls can be installed in a common gangable
wallbox or a series of interconnected wallboxes for a
clean, consolidated appearance. Lutron multigang
faceplates are available to complete the installation.
Refer to instruction sheet supplied with multigang
faceplates for installation.
For new installations, controls can be ganged without
removing side sections, but, to reduce the size of the
multigang installation or to fit existing wallboxes, inner
side sections must be removed. Because side sections
are designed to dissipate heat, removing them requires
derating the capacity of the control.
Note: When ganging any combination of small and
large controls, place all small controls on one end of the
gang and all large controls on the other. Use the chart
below to determine the size and rating of each control.
Control Size and Rating Chart
Control No Sides 1 Side 2 Sides
Model Size Removed Removed Removed
NT-600 S 600W 500W 400W
NT-1000 S 1000W 900W 700W
NT-1500 L 1500W 1250W 1000W
NT-2000
* L 1950W
NTLV-600 S 600VA 500VA 300VA
NTLV-1000 S 1000VA 900VA 700VA
NTLV-1500 L 1500VA 1200VA 1000VA
NT-603P S 600W 500W 400W
NT-1003P S 1000W 900W 700W
NT-1503P L 1500W 1250W 1000W
NTLV-603P S 600VA 500VA 300VA
NTLV-1003P S 1000VA 900VA 700VA
NTLV-1503P L 1500VA 1250VA 1000VA
NTELV-300 S 300W 300W 250W
NTELV-600 S 600W 500W 400W
NTFS-6E S 6A 4.2A 2.5A
NTFS-12E L 12A 10A 8.3A
NTFSQ S 1.5A 1.5A 1.5A
NTF-10 S 16A 16A 16A
NTF-10-277 S 8A 8A 8A
NTFTU-5A S 5A 4A 3.3A
NT-1PS S 20A 20A 20A
NT-3PS S 20A 20A 20A
NT-4PS S 20A 20A 20A
*NT-2000 cannot have side sections removed.
The Wallbox Requirement Charts on this sheet do not apply
for the NT-2000. See the NT-2000 instruction sheet for the
appropriate requirements.
Warranty
Lutron will, at its option, repair or replace any unit that is defective in materials or
manufacture within one year after purchase. For warranty service, return unit to place of
purchase or mail to LUTRON at 7200 Suter Road, Coopersburg, PA 18036-1299, postage
prepaid.
This warranty is in lieu of all other warranties, express or implied, and the implied
warranty of merchantability is limited to one year from purchase. This warranty does
not cover the cost of installation, removal, or reinstallation, or damage resulting from
misuse, abuse, or damage resulting from improper wiring or installation.
This warranty gives you specific legal rights, and you may also have other rights which vary
from state to state. Some states do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty may last, so the
above limitations may not apply to you.
Worldwide Technical and Sales Assistance
If you have questions concerning the installation or
operation of these products, call the
Lutron Technical
Assistance Hotline.
Please provide exact model
number when calling.
(800) 523-9466 (U.S.A., Canada, and the Caribbean)
Other Countries call (610) 282-3800
Fax (610) 282-3090
Visit our Web site at www.lutron.com
Side Sections Removed
(Derating Required)
Wallbox Requirement Chart
Number of Small Controls
0123456
00123456
Number 11345678
of Large 235678910
Controls 35789101112
4 7 9 10 11 12 13 14
Remove inner side sections from controls. Using pliers,
bend side sections up and down until they break off.
No Side Sections Removed
(Derating Not Required)
Wallbox Requirement Chart
Number of Small Controls
01234
0 0 1 1+1 4 4+1
Number 113568
of Large 2467810
Controls 3 6 8 10 11 13
4 9 11 12 14 15
Note: When ganging an even number of small
controls with side sections intact, use gangable 3"x2"
wallboxes. Space an additional wallbox 3/4" apart from
the other wallboxes. A 3/4" chase nipple is
recommended as a spacer between wallboxes.
Example: Wallbox arrangement required for ganging 4
small controls with no side sections removed:
Remove inner side
sections (shaded) only.
Do not remove outer
side sections.
Single-gang
gangable
wallbox
3/4" space
(use chase
nipple)
Four-gang gangable wallbox