Information Sheet
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987d 17 12.12.18
Multi-Location Installation
WithPicoremotecontrols(PJ2-XX-XX)andwallboxmountingadapters(PICO-WBX-ADAPT)
PD-10NXD and PD-5NE
120V~
50 / 60 Hz
Neutral
Red
Green
Ground
Load
Line / Hot
Black
Pico
remote
control &
wallbox
mounting
adapter
Pico
remote
control &
wallbox
mounting
adapter
In-Wall
Dimmer
Black
Travelers
White
3,4
Blue
1, 5
Travelers
120V~
50 / 60 Hz
Neutral
Black
Green
Ground
Load
Line / Hot
Black
Pico
remote
control &
wallbox
mounting
adapter
Pico
remote
control &
wallbox
mounting
adapter
In-Wall
Dimmer
Black
PD-6WCL
Travelers
Travelers
Location 1 Location 2 Location 3
Wiring Diagrams - Dimmers (cont.)
1
When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.
2
Location of Caséta Wireless in-wall dimmer PRO and mechanical switch may be reversed.
3
ForPD-10NXDonly,neutralconnectionoptionalexceptforMLVloads,LEDdrivers,andpowermodules(PHPM-PA,PHPM-3F,andGRX-TVI).
4
ForPD-5NE,neutralisrequired.
5
Blue wire is only present on the PD-10NXD model.