Information Sheet

®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987d 18 12.12.18
Wiring Diagrams - Dimmers (cont.)
3-Way Installation
With mechanical switch
In-Wall
Dimmer
2
Mechanical
Switch
2
Brass
Brass
Load
Line/Hot
Neutral
Green
Ground
Ground
Black
Red
Blue
120V~
50/60 Hz
Black
Jumper wire
(included)
White
3
PD-10NXD
1
When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.
2
Location of in-wall dimmer and mechanical switch may be reversed.
3
NeutralconnectionoptionalexceptforMLVloads,LEDdrivers,andpowermodules(PHPM-PA,PHPM-3F,andGRX-TVI).
4
See Lutron P/Ns 369356 and 369355 for additional wiring diagrams.
5
Blue wire is only present on the PD-10NXD model.
Installation with PHPM - Neutral required
4
L/H
N
DH
In-Wall
Dimmer
Neutral
Line/Hot
120V~
60 Hz
Black
Ground
Ground
White
Green
Blue
1, 5
Red
PHPM
Load
Control Neutral
Zone In
PD-10NXD and PD-5NE
Location 1
Location 2
Location 1
18