Information Sheet

®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Caséta Wireless Load Controls
369987d 4 12.12.18
Load Type and Capacity - Switches and Fan Control
Model Number Description Voltage Load Type Minimum Load
Maximum Load
3
Not Ganged End of Gang Middle of Gang
PD-5WS-DV
1
Two-wire
switch
120V~
Incandescent /
Halogen
25 W 600 W 450 W 350 W
277V~
Incandescent /
Halogen
25 W 1350 W 110 0 W 800 W
120V~ MLV 25 W 600VA/475W 450VA/350W 350VA/275W
277V~ MLV 25 W 1350VA/1075W 1100VA/875W 800VA/625W
120V~
General
Purpose Fan
0.4 A 3 A 3 A 3 A
120/277V~ LED UseLUT-MLC
2
5 A 4 A 3 A
120/277V~ Fluorescent UseLUT-MLC
2
5 A 4 A 3 A
120V~ ELV UseLUT-MLC
2
600 W 450 W 350 W
277V~ ELV UseLUT-MLC
2
1350 W 110 0 W 800 W
PD-5ANS
Neutral-wire
switch
(neutral
connection
required)
120V~
Incandescent /
Halogen
10 W 600 W 600 W 600 W
MLV 10 W
600VA 600VA 600VA
Fan 0.1 A 3 A 3 A 3 A
LED 1 bulb 5 A 5 A 5 A
Fluorescent 1 ballast 5 A 5 A 5 A
ELV 10 W 600 W 600 W 600 W
PHPM-SW 1 interface 2 interfaces 2 interfaces 2 interfaces
PD-6ANS
Neutral-wire
switch
(neutral
connection
required)
120V~
Incandescent /
Halogen
10 W 720 W 720 W 600 W
MLV 10 W
720VA 720VA 600VA
Fan 0.1 A 3.6 A 3.6 A 3.6 A
LED 1 bulb 6 A 6 A 5 A
Fluorescent 1 ballast 6 A 6 A 5 A
ELV 10 W 720 W 720 W 600 W
PHPM-SW 1 interface 3 interfaces 3 interfaces 3 interfaces
PD-FSQN
4
Fan speed
control
(neutral
connection
required)
120V~
Ceiling Fan
(Permanent
split-capacitor
motor)
0.1 A 1.5 A 1.5 A 1.5 A
1
No neutral wire required.
2
ToensureproperoperationoftheswitchwithLED,fluorescent,andELVloads,aLUT-MLC(included)mayberequired,especiallyatlowerwattages.Ifthe
statusLEDontheswitchisflashingorsolidredincolor,aLUT-MLCmustbeinstalled.Toguaranteebestperformance,installingaLUT-MLCwiththeseload
typesregardlessofwattageisrecommended.Rarely,someloadtypesmaystillflickerorglowintheoffstateevenwiththeLUT-MLCinstalled,inwhichcase
adifferentloadmayberequiredormorethanoneLUT-MLCisrequired.
3
See“GangingandDerating”section.
4
Notforusewithfansthathaveintegratedfanspeedand/orlightcontrolmodules,DCmotorfans,fanswithremotecontrols,bathroomorkitchenexhaust
type fans.
4