Installation Guide

Find the right LED
lutron.com/LEDfinder
INSTALL WITH CONFIDENCE
LED
+
Dimmer 120 V~ 60 Hz
Quick Install Guide
Install with
confidence
Use included diagrams
or visit our website for
step-by-step instructions.
®
Limited Warranty: www.lutron.com/TechnicalDocumentLibrary/369-119_Wallbox_Warranty.pdf ©2020 Lutron Electronics Co., Inc.
Lutron and LED+ are trademarks or registered trademarks of Lutron Electronics Co., Inc., in the U.S. and other countries.
The YouTube icon is a trademark of Google LLC.
English
Receive an Extended Warranty: www.lutron.com/CLregistration
Support: 1.844.LUTRON1 (USA / Canada) +1.888.235.2910 (Mexico)
How-to videos
lutron.com/CLwiring
lutron.com/CLwiring
VIDEO & STEP-BY-STEP INSTRUCTIONSVIDEO & STEP-BY-STEP INSTRUCTIONS
* Maximum Allowable Inc. / Hal. Wattage
Single
Gang
End of Gang Middle of Gang
600 W 450 W 300 W
1. CAUTION: Use only with permanently installed fixtures with
dimmable screw-in compact fluorescent, dimmable screw-in
LED, halogen, or incandescent lamps. To avoid overheating
and possible damage to other equipment, do not use to control
receptacles, motor-driven appliances, or transformer-supplied
appliances.
2. Install in accordance with all national and local
electrical codes.
3. When no “grounding means” exists in wallbox, the National
Electrical Code (NECR) allows a control to be installed as a
replacement when a plastic faceplate with plastic fasteners is
used, or the circuit is protected by a ground fault circuit interrupter
(GFCI). Lutron wallplates meet this requirement. Cap or remove
green wire before screwing control into wallbox.
4. Protect the dimmer from dust and dirt when painting or spackling
the wall.
5. It is normal for the dimmer to feel warm to the touch during
operation.
6. Clean the dimmer with a soft damp cloth only. Do not use any
chemical cleaners.
7. For indoor use only.
Important Notes
Please read before installing
Ganging and Derating
Derating is necessary if mounting two
or more devices side by side (see
chart for new wattage rating).
Note: Derating not necessary for LED /
CFL loads.
Bend back
and forth
RCL-153PNL
150 W
LED / CFL
600 W *
Incand. / Halogen
Ground wire
(bare or green)
Ground wire
(bare or green)
Tag
IMPORTANT: Mark or tag the common wire
(connected to the different colored screw)
before removing the old switch.
Insert and
twist to
tighten
Insert and
twist to
tighten
Use blue
connector
Green wire
Green wire
Single Pole 3-Way
For lights switched from one location: For lights switched from two locations:
OR
WARNING: ELECTRIC SHOCK
HAZARD. May result in serious
injury or death. Turn off power at
circuit breaker or fuse
before installing.
ON
OFF
AFTER INSTALLATION: Adjust low-end dimming range for LEDs and CFLs
Mount Dimmer and Restore Power
1. Push shaft to turn lights on and rotate counter-clockwise
to adjust the low-end.
2. Move adjustment lever up or down to adjust the low-end
dimming range.
3. Push shaft to turn lights OFF and ON to verify proper
operation.
1. Attach faceplate
2. Note the UP arrow 3. Push the light ring on
4. Push the knob on firmly
Before installing remove the rotary knob and the light ring.
NOTE: Only one dimmer can be used in a 3-way circuit.
NOTE: Black and solid red wire on the dimmer are interchangeable.
A
d
j
u
s
t
m
e
n
t
L
e
v
e
r
1.
2.
Pull hard
Pinch sides and
pull to remove ring
NOTE: It may be helpful
to attach the knob for
this step.
For Troubleshooting, please visit www.lutron.com/support
Push hard
P/N 0301964 REV A