product specifications
01.21.11
369-225f
1
Dimmer Load Type: -6D, -10D, and -10ND are designed for use with permanently installed incandescent, magnetic low-voltage, or
tungsten halogen only. -6NA is designed for use with permanently installed incandescent, electronic low-voltage, magnetic low-voltage,
or tungsten halogen only. Do not install dimmers to control receptacles or motor-operated appliances.
2
Low-Voltage Applications: Use -6D, -10D and -10ND with magnetic (core and coil) low-voltage transformers only. Not for use with
electronic (solid-state) low-voltage transformers. Use -6NA with electronic (solid-state) or magnetic (core and coil) transformers.
Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron
strongly recommends the following:
Do not operate low-voltage circuits without operative lamps in place.
Replace burned-out lamps as soon as possible.
Use transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent.
3
Fluorescent Dimmer Load Type: -F6AN-DV is designed for use with permanently installed 3-wire 120 V
or 277 V line voltage control
fluorescent ballasts or LED drivers. Use only with Hi-lume®, Hi-lume® 3D, Compact SETM, Eco-10®, or Ecosystem® (H3D-, FDB-, ECO-,
HL3-, EC5-, L3D). Do NOT use with any other ballasts or drivers. Do not install to control receptacles or motor-operated appliances.
4
Power Boosters / Load Interfaces: -10ND, -6NA, -F6AN-DV, and -8ANS can be used to control power boosters / load interfaces. For a list
of compatible power boosters / load interfaces see Compatible Power Boosters and Load Interfaces below.
5
Maximum Load: The maximum load for the -F6AN-DV is either the derated load or the number of ballasts, whichever is LESS.
6
Switch Load Type: -8ANS and -8S-DV are designed for use with permanently installed 120 V
incandescent, magnetic low-voltage,
electronic low-voltage, tungsten halogen, fluorescent, or motor loads. -8S-DV can also be used with permanently installed 277 V
magnetic low-voltage or fluorescent loads.
7
Shunt Capacitor: Some -8S-DV installations may require the use of a shunt capacitor (included with -8S-DV). This is especially necessary
for load types sensitive to leakage current (i.e. fluorescent ballasts). If load flickers, install a shunt capacitor. Optional shunt capacitor
must be installed inside the load fixture or in a separate J-box. For shunt capacitor installation see Wiring Diagram 4, 9, or 10.
RadioRA 2 Maestro® Local Controls
Load Type and Capacity (continued)
Control Phase Adaptive
Power Modules
(PHPM-PA-120-WH
& PHPM-PA-DV-WH)
3-wire Fluorescent
Power Modules
(PHPM-3F-120-WH
& PHPM-3F-DV-WH)
Switched Power
Module
(PHPM-SW-DV-WH)
0-10 V Interface
and Switching
Module
(GRX-TVI)
RRD-10ND
RRD-6NA
RRD-F6AN-DV
RRD-8ANS
(preferred)
Compatible Power Boosters and Load Interfaces
Some local controls can be used to control power boosters or load interfaces. Up to three power
boosters or load interfaces can be used with one control. See table below for a list of controls and
compatible power boosters and load interfaces.